Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply

  • Analog programming
  • Zero voltage “soft switching”
  • Constant voltage or constant current operation with automatic crossover and mode indication
  • Standby/Remote/Local modes
  • Front panel button preview of voltage, current, OVP
  • Remote sense, 5 V line loss compensation
  • LabVIEW® and LabWindows® drivers

Sorensen XFR Series Specifications
Common
Switching Frequency XFR 2.8 kW: Nominal 31 kHz (62 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz 

(125 kHz output ripple).
Time Delay 7 sec maximum from power on until output stable
Voltage Mode Transient Response Time < 3 ms for output voltage to recover within 0.5% of its rated voltage after a step change in load current of up to 10% to 90%

of rated output
Maximum Voltage Differential ±600 Vdc from output to safety ground
Remote Start/Stop and Interlock 2.5-15 V signal or TTL-compatible input, selectable logic
Remote Analog Programming Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V (default) voltage sources
Remote Analog Monitoring Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output
Remote Programming & Monitoring Accuracy 1% zero to full scale output for the default range
Maximum Remote Sense Line Drop Compensation 5 V / line (Line drop is subtracted from total voltage available at supply output.)
Front Panel Voltage and Current Control 10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution 0.02% of maximum voltage
Main Output Connector XFR 2.8 kW: 7.5 - 100 V models: nickel-plated copper bus bars with bus bar cover and strain relief; 150V to 600 V models: 4-terminal, wire clamp connector with cover and strain relief
Approvals NRTL approved and CE-marked to UL Std. No. 61010-1, CAN/CSA-C22.2 No. 61010-1-04, EN 610101-1 (Equipment Class I, Pollution Degree 2, Installation Category II) Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A.
Input
Input Voltage Ranges XFR 2.8 kW: 190-264 Vac, 1φ (24.3 A @ 208 Vac; 20.5 A @ 230 Vac typical), 47-63 Hz; Option: M2 3φ 208 Vac input
AC Input Connector Type 3-terminal, 34 A, 250 V, wire clamp connector with strain relief cover
Protection Features
Over-voltage protection  
Over-temperature protection  
Environmental
Operating Temperature XFR 2.8 kW: 0 to 50°C,
Storage Temperature -20°C to 70°C
Humidity (Non-condensing) Up to 90% RH, non-condensing
Physical
Model XFR 2.8 kW
Dimensions Width: 19” (429.4 mm)

Height: 3.5” (88.9 mm)

Depth: 21” (533.5 mm
Weight 33 lb (15 kg)
Output Ratings
Model Output Voltage Output Current Output Power
XFR 7.5-300 0-7.5 V 0-300 A 2250 W
XFR 12-220 0-12 V 0-220 A 2640 W
XFR 20-130 0-20 V 0-130 A 2600 W
XFR 33-85 0-33 V 0-85 A 2805 W
XFR 40-70 0-40 V 0-70 A 2800 W
XFR 60-46 0-60 V 0-46 A 2760 W
XFR 100-28 0-100 V 0-28 A 2800 W
XFR 150-18 0-150 V 0-18 A 2700 W
XFR 300-9 0-300 V 0-9 A 2700 W
XFR 600-4 0-600 V 0-4 A 2400 W
Line Regulation
Model Voltage Current
XFR 7.5-300 2.75 mV 32 mA
XFR 12-220 3.2 mV 24 mA
XFR 20-130 4 mV 15 mA
XFR 33-85 5.3 mV 10.5 mA
XFR 40-70 6 mV 9 mA
XFR 60-46 8 mV 6.6 mA
XFR 100-28 12 mV 4.8 mA
XFR 150-18 17 mV 3.8 mA
XFR 300-9 32 mV 2.9 mA
XFR 600-4 62 mV 2.4 mA
Load Regulation
Model Voltage Current
XFR 7.5-300 6.5 mV 65 mA
XFR 12-220 7.4 mV 49 mA
XFR 20-130 9 mV 31 mA
XFR 33-85 11.6 mV 22 mA
XFR 40-70 13 mV 19 mA
XFR 60-46 17 mV 14.2 mA
XFR 100-28 27 mV 10.6 mA
XFR 150-18 35 mV 8.6 mA
XFR 300-9 65 mV 6.8 mA
XFR 600-4 125 mV 5.8 mA
Meter Accuracy
Model Voltage (1% of Vmax + 1 count) Current (1% of lmax + 1 count)
XFR 7.5-300 0.09 V 4 A
XFR 12-220 0.13 V 2.3 A
XFR 20-130 0.3 V 1.4 A
XFR 33-85 0.43 V 0.95 A
XFR 40-70 0.5 V 0.8 A
XFR 60-46 0.7 V 0.56 A
XFR 100-28 1.1 V 0.38 A
XFR 150-18 1.6 V 0.19 A
XFR 300-9 4 V 0.1 A
XFR 600-4 7 V 0.05 A
Output Ratings
Model Output Noise (0-20 MHz) Output Ripple (rms)
Voltage (p-p) Voltage Current
XFR 7.5-300 100 mV 10 mV 1600 mA
XFR 12-220 100 mV 10 mV 1200 mA
XFR 20-130 100 mV 10 mV 400 mA
XFR 33-85 100 mV 15 mV 300 mA
XFR 40-70 150 mV 15 mV 200 mA
XFR 60-46 150 mV 15 mV 100 mA
XFR 100-28 175 mV 25 mV 80 mA
XFR 150-18 200 mV 25 mV 40 mA
XFR 300-9 400 mV 40 mV 20 mA
XFR 600-4 500 mV 100 mV 10 mA
Output Ratings
Model Drift (8 hours)
Voltage (0.5% of Vmax) Current (0.05% of lmax)
XFR 7.5-300 3.75 mV 150 mA
XFR 12-220 6 mV 110 mA
XFR 20-130 10 mV 65 mA
XFR 33-85 16.5 mV 42.5 mA
XFR 40-70 20 mV 35 mA
XFR 60-46 30 mV 23 mA
XFR 100-28 50 mV 14 mA
XFR 150-18 75 mV 9 mA
XFR 300-9 150 mV 4.5 mA
XFR 600-4 300 mV 2 mA
Output Ratings
Model Temp Coeffcient
Voltage (0.02% of Vmax ºC) Current (0.03% of Vmax ºC)
XFR 7.5-300 1.5 mV 90 mA
XFR 12-220 2.4 mV 66 mA
XFR 20-130 4 mV 39 mA
XFR 33-85 6.6 mV 25.5 mA
XFR 40-70 8 mV 21 mA
XFR 60-46 12 mV 13.8 mA
XFR 100-28 20 mV 8.4 mA
XFR 150-18 30 mV 5.4 mA
XFR 300-9 60 mV 2.7 mA
XFR 600-4 120 mV 1.2 mA
Output Ratings
Model Program Slew Rate
Rise time Fall time
XFR 7.5-300 100 ms 100 ms
XFR 12-220 100 ms 100 ms
XFR 20-130 100 ms 100 ms
XFR 33-85 100 ms 100 ms
XFR 40-70 100 ms 100 ms
XFR 60-46 100 ms 100 ms
XFR 100-28 170 ms 170 ms
XFR 150-18 170 ms 170 ms
XFR 300-9 170 ms 170 ms
XFR 600-4 170 ms 170 ms
Output Ratings
Model OVP Adjustment Range 

(5% to 110% of Vmax)
Efficiency
XFR 7.5-300 0.375-8.25 V 80%
XFR 12-220 0.6-13.2 V 82%
XFR 20-130 1-22 V 85%
XFR 33-85 1.65 - 36.6 V 85%
XFR 40-70 2-44 V 87%
XFR 60-46 3-66 V 90%
XFR 100-28 5-110 V 90%
XFR 150-18 7.5-165 V 90%
XFR 300-9 15-330 V 91%
XFR 600-4 30-660 V 91%
Interface Specifications with RS-232 or GPIB Interface Installed
Model Program Accuracy
Voltage (mV) Current (mA) OVP (mV)
XFR 7.5-300 10 +0.12% 900 +0.15% 40
XFR 12-220 75 +0.12% 750 +0.15% 75
XFR 20-130 75 +0.12% 500 +0.15% 100
XFR 33-85 75 +0.3% 425 +0.1% 175
XFR 40-70 75 +0.3% 350 +0.15% 200
XFR 60-46 150 +0.3% 250 +0.1% 300
XFR 100-28 150 +0.35% 140 +0.15% 500
XFR 150-18 225 +0.35% 120 +0.1% 750
XFR 300-9 225 +0.35% 80 +0.1% 1500
XFR 600-4 300 +0.35% 80 +0.1% 3000
Interface Specifications with RS-232 or GPIB Interface Installed
Model Readback Accuracy
Voltage (mV) Current (mA)
XFR 7.5-300 30 +0.12% 900 +0.1%
XFR 12-220 75 +0.12% 750 +0.1%
XFR 20-130 75 +0.2% 500 +0.1%
XFR 33-85 75 +0.3% 425 +0.1%
XFR 40-70 75 +0.3% 350 +0.1%
XFR 60-46 150 +0.35% 250 +0.1%
XFR 100-28 150 +0.35% 140 0.1%
XFR 150-18 225 +0.35% 120 +0.1%
XFR 300-9 225 +0.35% 80 +0.1%
XFR 600-4 300 +0.35% 80 +0.1%

More Product Information

AMETEK Programmable Power

Located in San Diego, California, AMETEK Programmable Power designs, manufactures, and markets precision, AC and DC programmable power supplies, electronic loads, application specific power subsystems, and compliance test solutions for customers requiring and valuing differentiated power products and services. Also part of our business is VTI Instruments, which delivers precision modular instrumentation and systems for electronic signal distribution, acquisition, and monitoring, used in the world's most demanding test applications. 

AMETEK Programmable Power boasts one of the industries' broadest portfolios of programmable power products under the well-known and respected Sorensen, Elgar, and California Instruments brands. AMETEK Programmable Power’s products serve a wide range of stimulus (T&M) and process power needs in applications including semiconductor fabrication, commercial and defense ATE, oil exploration, solar array and battery string simulation, avionics, general R&D and EMC compliance testing. 

VTI Instruments provides products and systems which are used to monitor and record data that characterizes the physical integrity and performance of aircraft, engines, and other large structures, as well as automate the functional testing of complex electronic systems. VTI Instruments is recognized as an industry leader with a reputation of providing reliable data, first time, every time. 

With strong brands, a broad product portfolio, exceptional precision power conversion and control expertise, proven power system integration capabilities and deep applications knowledge, AMETEK Programmable Power is your source for programmable power supplies, precision data acquisition instruments, and more.


Contact Details 

AMETEK Programmable Power, Inc. − San Diego 

9250 Brown Deer Road, San Diego, CA 92121, USA

Phone: 858-450-0085 

Fax: 858-458-0267 

Email: sales.ppd@ametek.com for general inquiries

Contact form

Test & Measurement

Download Line Card
Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply
Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply
Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply
Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply