Teledyne LeCroy MDA800A Motor Drive Analyzers

Product Overview:

  • Complete Motor Drive System Debug and Validation in One Instrument
  • Three-Phase Power Measurements; Real, Apparent, Reactive Power
  • Efficiency Measurements
  • User-Configurable Numerics Table
  • Two- and Three-Wattmeter Methods Supported
  • Per-Cycle Time-Correlated Waveforms From Power Values
  • Harmonics Calculations and Filtering (optional)
  • Dynamic Drive Response Analysis, From Startup To Overload
  • Unique Zoom+Gate Mode
  • Line-Line To Line-Neutral Voltage Conversion
  • Up to 6000 VRMS Isolation with HVD Series Differential Probes
  • Easily Interface Other Current Measurement Devices
  • Complete Motor Interface (Torque, Speed, Position)
  • Graphical User Interface

More

Motor Drive Analyzers provide complete three-phase electrical and mechanical power analysis with static power results in a convenient, configurable Numeric table and dynamic power displayed as per-cycle Waveforms. Motor speed, position, and torque integration are the most complete available. Zoom+Gate mode provides ability to understand and isolate dynamic behaviors. Long memory, 8 analog input channels (MSO optional) with high resolution (12-bits), sample rate, bandwidth and memory (up to 250 Mpt/ch) provides unique capability to perform complete system debug on the inverter subsection, embedded control system, and motor mechanical performance.

Key Features

  • Oscilloscope + Power Analyzer in one instrument
    • Static power analysis (like a power analyzer)
    • Dynamic power analysis (unique to the MDA)
    • Complete system debug capabilities (unique to the MDA)
  • Zoom+Gate
  • Comprehensive speed and torque interface
  • Harmonics Analysis option (MDA800-HARMONICS)
  • Intuitive, graphical user interface

Oscilloscope + Power Analyzer

The Motor Drive Analyzer is built on the 8ch/12-bit HDO8000A platform. It contains all of the advanced oscilloscope capability you need for embedded control debug plus three-phase power and mechanical analysis with accuracy to within 1% of a dedicated power analyzer instrument.

Static Power Analysis

Like a power analyzer, the MDA can acquire short records under steady-state operating conditions and provide fast updates of mean value power quantities in the Numerics table. Power quantities can be calculated on a line frequency AC period, a variable frequency PWM output period, or over a very short time period, such as the device switching period.

Dynamic Power Analysis

Long memory (up to 250 Mpts/ch) permits capture and analysis of long periods of time (e.g. 25 seconds at 10 MS/s). Touch a Numerics table cell and create a per-cycle "synthesized" Waveforms of the parameter over time.Zoom+Gate adds further value for dynamic analysis. Correlate complex drive behaviors to other control or power system waveforms, and debug drive system problems faster.

Complete System Debug

Power Analyzer instruments perform only one function, and typical 4 channel oscilloscopes have limited capabilities for three-phase power system analysis. The Motor Drive Analyzer has 8 analog input channels (+16 optional digital channels) and three-phase power analyzer capability to debug the complete motor drive system.

Zoom+Gate

Zoom your acquisitions and Gate both the Numerics measurement table and the per-cycle Waveforms to the zoomed area. Gain deeper and faster understanding of complex drive and control system behaviors.

Harmonics Analysis Option

Apply a discrete fourier transform (DFT) harmonic filter to acquired voltage and current waveforms. Harmonically filter Numerics table results more accurately than brute force hardware filters. Display per-order Harmonics in a table along with up to 9 spectral waveforms. View per-cycle THD values over time.

Comprehensive Speed and Torque Interface

Interface digital or analog speed sensors with Angle Tracking Observer filtering. Extract speed information from CAN serial data. Use digital (MSO) inputs to conserve valuable analog channels. Interface a variety of torque sensors, extract torque from CAN serial data, or infer torque from motor current and a known torque constant. At your bench, calculate motor Speed and Torque without additional expensive equipment.

Intuitive, graphical user interface

An easy-to-understand user interface guides the operator through setup and analysis. Setup capability is provided for any combination of single-phase or three-phase drive input/output. Quick buttons provide fast access to advanced capabilities.

Main Specifications

Bandwidth 350 MHz - 1 GHz
Starting from $30,900
Standard Memory 50 Mpts - 250 Mpts
Max Sampling Rate 10 GS/s
Input Channels 8
Resolution 12-bit

 
00:00
 
00:00

More Product Information

  • Teledyne LeCroy’s unique summary view displays the Eye Pattern, TIE, Bathtub Curve and Jitter Histogram all on the screen at the same time
  • De-embed cables allow all of the SDA tools to be used as if the cables were not in the system
  • Create Eye Patterns utilizing the full memory for maximum statistical significance
  • Display Eye Patterns up to 100 times faster than other solutions
  • Trigger on 80-bit patterns at up to 3.125 Gb/s using the Serial Trigger
  • Decode 8b/10b data on up to 4 lanes simultaneously
  • Configure software PLL for any standard or custom requirement
  • Serial data compliance testing
    • 10/100/1000 BaseT ENET
    • USB 2.0
    • MIPI D-PHY
    • DDR2 / DDR3
    • PCI Express
    • DisplayPort
    • SAS
    • HDMI
    • UWB
    • SATA

  • Teledyne LeCroy's unique summary view displays the Eye Pattern, TIE, Bathtub Curve and Jitter Histogram all on the screen at the same time
  • De-embed cables allow all of the SDA tools to be used as if the cables were not in the system
  • Create Eye Patterns utilizing the full memory for maximum statistical significance
  • Display Eye Patterns up to 100 times faster than other solutions
  • Triggers on 80-bit patterns at up to 3.125 Gb/s using the Serial Trigger
  • Decode 8b/10/b data on up to 4 lanes simultaneously
  • Configure software PLL for any standard or custom requirement
  • Serial Data compliance testing
    • ​10/100/1000 BaseT ENET
    • USB 2.0
    • MIPI D-PHY
    • DDR2 / DDR3
    • PCI Express
    • DisplayPort
    • SAS
    • HDMI
    • UWB
    • SATA

  • Provides complete S-parameter measurements on up to 12 ports
  • Measures from DC to 40 GHz
  • One-button-press internal OSLT calibration
  • Analyzes in both frequency and time domain
  • Produces mixed-mode and single-ended simulation-ready S-parameters
  • Remove effects from fixtures, connectors and launches using either Time Gating or S-parameter de-embedding
  • Inherent TDR/TDT capability and preview modes for quick checks and debugging
  • Characterizes crosstalk of multi lane differential structures
  • Available at a fraction of the cost of other network analyzer solutions

Teledyne LeCroy offers a 15% discount on all Oscilloscopes, Probes and Options to education institutions

  • 1GHz, 10 GS/s, up to 16 Mpts/ch
  • MAUI with OneTouch
    • Designed for Touch
    • Built for simplicity
    • Made to solve
  • WaveScan - Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode - Waveform Playback
  • Sequence Mode Segmented Memory
  • Power Analysis Software
  • Serial Trigger and Decode 
    • I2C SPI, UART
    • CAN, LIN, FlexRay, SENT
    • Ethernet 10/100BaseT, USB 1.0/1.1/2.0, USB2.0-HSIC
    • Audio (I2S, LJ, TDM)
    • MIPI D-PHY, DigRF 3G, DigRF v4
    • Manchester, NRZ

  • Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope
  • Automatic probe detection
  • Provides all necessary power and offset control to the attached probe
  • Supports probes up to 4 GHz
  • Easy firmware updates
  • Wide variety of probes supported including:
    • Preamplifiers
    • Current Probes
    • Single-Ended Active Probes
    • Differential Active Probes

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

All fixed-attenuation, standard probes automatically re-scale any LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.

  • Up to 30 GHz bandwidth and 80 GS/s sample rate
  • Most advanced oscilloscope user interface makes configuring complex measurements easy
  • The industry’s only true hardware 14.1 Gb/s serial pattern trigger
  • Add the Teledyne LeCroy HDA125 High-speed Digital Analyzer to create the most powerful, flexible mixed-signal test solution available
  • Low Jitter Measurement Floor and exceptional timebase stability
  • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
  • Integrated standard and custom measurements and math functions for unrivaled analysis capability
  • Multi-lane serial data eye, jitter and crosstalk analysis

  • 1 GHz, 10 GS/s, up to 16 Mpts/ch
  • MAUI - Advanced User Interface
    • ​Designed for Touch
    • Built for Simplicity
    • Made to Solve
  • WaveScan- Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • 10.4" Touch Screen Display
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial trigger and Decode
  • Advanced Debug Toolkit adds: 
    • 10 GS/s on all 4 channels
    • 16 Mpts/ch memory (32 Intlv'd)
    • Sequence Mode Segmented Memory
    • History Mode Waveform Playback
    • 13 Additional Math Operators
    • 2 Math Functions

Teledyne LeCroy

Phone: 800-553-2769 or 845-425-2000

Fax Sales: 845-578-5985

Email Support: support@teledynelecroy.com (Oscilloscopes, Waveform Generators, Signal Integrity)

Email Sales: contact.corp@teledynelecroy.com

Phone Support: 1-800-553-2769

Our oscilloscopes offer a powerful combination of large and informative displays combined with advanced waveshape analysis capabilities - typically tailored to enhace the productivity of engineers inspecific applications areas such as serial data test, disk drive test and automotive bus analysis. 
Oscilloscopes Bandwidth Input Channels Resolution Max Sampling Rate Memory
200 MHz - 750 MHz 2,4 8-bit 4 GS/s 10 Mpts
200 MHz - 1 GHz 4 8-bit 10 GS/s 16 Mpts - 32 Mpts
1 GHz 4 8-bit 10 GS/s 16 Mpts - 32 Mpts
1GHz 4 8-bit 10 GS/s 16 Mpts - 32 Mpts
200 MHz - 1 GHz 4 12-bit 10 GS/s 12.5 Mpts - 25 Mpts
400 MHz - 4 GHz 4 8-bit 40 GS/s 16 Mpts - 64 Mpts
500 MHz - 4 GHz 4 8-bits 20 GS/s - 40 GS/s 32 Mpts - 128 Mpts (Interleaved)
350 MHz - 1 GHz 4 12-bit 10 GS/s 50 Mpts - 250 Mpts
350 MHz - 1 GHz 8 12-bit 10 GS/s 50 Mpts - 250 Mpts
350 MHz - 1 GHz 8 12-bit 10 GS/s 50 Mpts - 250 Mpts
1 GHz - 4 GHz 4 10-bit 20 GS/s - 40 GS/s 128 Mpts
1 GHz 4 10-bit 20 GS/s - 40 GS/s 128 Mpts
3.5 GHz - 6 GHz 4 8-bit 40 GS/s 32 Mpts - 256 Mpts
2.5 GHz - 6 GHz 4 8-bit 40 GS/s 32 Mpts - 256 Mpts
1.5 GHz - 6 GHz 4 8-bit 40 GS/s 20 Mpts - 256 Mpts
4 GHz - 30 GHz 4 8-bit 80 GS/s 32 Mpts - 512 Mpts
13 GHz - 30 GHz 4 to 80 8-bit 120 GS/s 20 Mpts - 768 Mpts
20 - 100 GHz 4 to 80 8-bit 240 GS/s 20 Mpts - 1024 Mpts
 

Line Cards: