Yokogawa 2406E Series Analog Insulation Tester (Multi Range)
Product Overview:
-
Analog models with two and three rating
-
AC voltage measurement
-
Automatic discharge
-
Sky blue EL backlight
-
Increased safety (covered battery charger)
Model Numbers
Model | Description |
---|---|
240641 | Rating 125V/20M~ 25V/5M~ 50V/10M~; Effective Measuring Range 0.001-5M~ 0.005-10M~ 0.01-20M~; AC Voltage Measurement 0 to 300 V ; Lower Limit 0.025M~ 0.05M~ 0.125~; Rated Current 1 mA |
240634 | Rating 1000V/2000M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-0M~ 0.05-100M~ 1-2000M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.25M~ 0.5M~ 1~; Rated Current 1 mA |
240633 | Rating 125V/20M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-20M~ 0.01-50M~ 0.05-100M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.125M~ 0.25M~ 0.5~; Rated Current 1 mA |
240642 | Rating 250V/50M~ ; Effective Measuring Range 0.01-50M~; AC Voltage Measurement 0 to 300 V ; Lower Limit 0.25; Rated Current 1 mA |
240643 | Rating 125V/20M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-20M~ 0.01-50M~ 0.05-100M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.125M~ 0.25M~ 0.5~; Rated Current 1 mA |
240645 | Rating 1000V/2000M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-0M~ 0.05-100M~ 1-2000M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.25M~ 0.5M~ 1~; Rated Current 1 mA |
240631 | Rating 125V/20M~ 25V/5M~ 50V/10M~; Effective Measuring Range 0.001-5M~ 0.005-10M~ 0.01-20M~; AC Voltage Measurement 0 to 300 V ; Lower Limit 0.025M~ 0.05M~ 0.125~; Rated Current 1 mA |
240644 | Rating 1000V/2000M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-0M~ 0.05-100M~ 1-2000M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.25M~ 0.5M~ 1~; Rated Current 1 mA |
240635 | Rating 1000V/2000M~ 250V/50M~ 500V/100M~; Effective Measuring Range 0.01-0M~ 0.05-100M~ 1-2000M~; AC Voltage Measurement 0 to 600 V ; Lower Limit 0.25M~ 0.5M~ 1~; Rated Current 1 mA |
240632 |
Rating 125V/20M~ ; Effective Measuring Range 0.01-20M~; AC Voltage Measurement 0 to 300 V ; Lower Limit 0.125~; Rated Current 1 mA |
Specifications - Model 240631
Rating |
125V/20M~ 25V/5M~ 50V/10M~ |
---|---|
Effective Measuring Range |
0.001-5M~ 0.005-10M~ 0.01-20M~ |
Central Scale Value |
0.1M~ 0.2M~ 0.5M~ |
AC Voltage Measurement | 0 to 300 V |
Lower Limit |
0.025M~ 0.05M~ 0.125~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240631
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240641
Rating |
125V/20M~ 25V/5M~ 50V/10M~ |
---|---|
Effective Measuring Range |
0.001-5M~ 0.005-10M~ 0.01-20M~ |
Central Scale Value |
0.1M~ 0.2M~ 0.5M~ |
AC Voltage Measurement | 0 to 300 V |
Lower Limit |
0.025M~ 0.05M~ 0.125~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240641
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240632
Rating | 125V/20M~ |
---|---|
Effective Measuring Range | 0.01-20M~ |
Central Scale Value | 0.5M~ |
AC Voltage Measurement | 0 to 300 V |
Lower Limit | 0.125~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Condtions - Model 240632
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240642
Rating | 250V/50M~ |
---|---|
Effective Measuring Range | 0.01-50M~ |
Central Scale Value | 1M~ |
AC Voltage Measurement | 0 to 300 V |
Lower Limit | 0.25~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240642
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240633
Rating |
125V/20M~ 250V/50M~ 500V/100M~ |
---|---|
Effective Measuring Range |
0.01-20M~ 0.01-50M~ 0.05-100M~ |
Central Scale Value |
0.5M~ 1M~ 2M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.125M~ 0.25M~ 0.5~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240633
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240343
Rating |
125V/20M~ 250V/50M~ 500V/100M~ |
---|---|
Effective Measuring Range |
0.01-20M~ 0.01-50M~ 0.05-100M~ |
Central Scale Value |
0.5M~ 1M~ 2M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.125M~ 0.25M~ 0.5~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240643
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240634
Rating |
1000V/2000M~ 250V/50M~ 500V/100M~ |
---|---|
Effective Measuring Range |
0.01-50M~ 0.05-100M~ 1-2000M~ |
Central Scale Value |
1M~ 2M~ 50M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Condtions - Model 240634
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - 240644
Rating |
1000V/2000M~ 250V/50M~ 500V/100M~ |
---|---|
Effective Measuring Range |
0.01-50M~ 0.05-100M~ 1-2000M~ |
Central Scale Value |
1M~ 2M~ 50M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240644
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240635
Rating |
1000V/2000M~ 250V/500M~ 500V/1000M~ |
---|---|
Effective Measuring Range |
0.1-500M~ 0.5-1000M~ 1-2000M~ |
Central Scale Value |
10M~ 20M~ 50M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240635
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240645
Rating |
1000V/2000M~ 250V/500M~ 500V/1000M~ |
---|---|
Effective Measuring Range |
0.1-500M~ 0.5-1000M~ 1-2000M~ |
Central Scale Value |
10M~ 20M~ 50M~ |
AC Voltage Measurement | 0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current | 1 mA |
Approx. Outer Scale Length | 88 mm |
Discharge Function | The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width | 120 mm |
Approx. Height | 110 mm |
Approx. Depth | 60 mm |
Approx. Weight | 500 g |
Batteries | Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240645
Ambient Temperature/Humidity Ranges | 23 ±5 /45-75% RH |
---|---|
Position of Use | Horizontal (5º max. of angle of inclination) |
External Magnetic Fields | None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
More Product Information
-
Analog models with single rating
-
MY10-01:125V/20MΩ
-
MY10-02:250V/50MΩ
-
MY10-03:500V/100MΩ
-
MY10-04:500V/1000MΩ
-
MY10-05:1000V/2000MΩ
-
-
AC voltage measurement
-
Automatic discharge
-
A wide choice of accessories-Designed for shared use with the MY40
-
Analog models with single rating
-
AC voltage measurement and check live lines such as motive power lines
-
One-touch operation Press-and-lock switch for continuous measurement
-
A wide choice of accessories to meet various testing requirements
-
Vibration - and shock-resistant hand-held compact testers
-
Approx weight including batteries, or Approx. weigh including hard case, handle, test leads and batteries
The AQ1300 series is a compact and lightweight Ethernet tester that is designed to improve both work efficiency and quality at the same time, with function optimized for the network path testing and maintenance of Ethernet networks up to 1G or 10G depending on model chosen.
Easy operation prevents operational errors and stabilizes work quality for routine tasks such as network path testing. Powerful analysis functions help isolate failures during maintenance work. The AQ1300 series has two models, AQ1300 and AQ1301 to choose from depending on the measurement interface and bit rate. You can choose the model suitable for your test needs.
-
Digital model with 4 voltage/resistance ratings
-
Multifunction
-
Insulation resistance, AC voltage and conductor resistance measurement
-
Insulation test mode: Comparator, memory, auto-hold and discharge functions
-
All test modes: Live-line alarm (excluding AC voltage measurement), battery check and automatic power-off
-
-
Easy-to-view, fluctuation-free display
-
Double-action safety mechanism
-
Weight including main unit and batteries only, excluding accessories
-
One ADC12D2000RF: Singlechannel 12-bit 4Gsps or dualchannel 12-bit 2Gsps
-
One AD9129: Single-channel 14-bit D/A up to 5.7 Gsps (2.85Gsps without 1:2 interpolation) - LVDS
-
VITA 57.1-2010 compliant
-
Single-ended, AC-coupled analog signals
-
6 MMCX/SSMC connectors available from the front panel
-
4 LVTTL signals available from an HDMI connector on the front panel
-
4 Xilinx MGT available from an HDMI connector on the front panel
-
Clock source, sampling frequency through SPI communication busses
-
Flexible clock tree enables:
-
Onboard VCO: 2200MHz - 4400MHz
-
External reference clock
-
External sampling clock
-
-
Power-down modes to switch off unused functions for system power savings
-
Mil-I-46058c Conformal Coating Compliant (optional)
-
HPC (high-pin count) compatible
-
LVDS IO signaling
-
Maximum configuration flexibility with multi-bay capacity
-
Digital measurement system 2 Waveform digitizers and 2×16, 100 MHz multiplexer
-
Expandable input measurement channels
-
Common interface panel
-
emPower™ Test Executive