California Instruments - CSW Series 5550 - 33300VA High Performance Programmable AC and DC Power Source

  • Combination AC and DC Power Source
  • 2Hz-7,990Hz Output Frequencies
  • Arbitrary and Harmonic Waveform Generation
  • Built-In Digital Power Analyzer
  • Scope Capture Capability
  • Power Programming Software
  • Constant Power Mode
  • Multi-Box Option

California Instruments CSW Series : Specifications
Input
Voltage Ranges Factory configured 187 to 264 Vrms, 3ø L-L (3 wire), or 342 to 457 Vrms, 3ø L-L (4 wire). A chassis ground is also required.
Power Factor PFC Input, 0.99PF
Frequency Range 47 to 440 Hz
Efficiency 70% min, at full load
Ride Through 10 ms minimum
Output
Power 5550 VA: 1ø or 3ø (systems up to 33,000 VA)
AC or DC Output Voltage 0 to156 Vrms L-N, low range; 0 to 312 Vrms L-N, high range
Current Per Phase 16A to 115V in 156V range; 8A to 230V in 312V range per, 1850 VA module.

Available current in either AC, DC or AC+DC mode.
Power Factor of Load 0 lagging to 0 leading (0-unity)
Crest Factor 3.25:1 (peak output current to rms output current)
Frequency Range Specifications apply DC, 40Hz to 5kHz. For output frequencies greater than 1 kHz, the max slew rate allowed is 1 kHz per second.
Max Total Harmonic Distortion (Full Linear Load or No Load): 0.25% max, 40 to 100 Hz; 0.5% max to 500 Hz; and 1% max to 1 kHz plus 1%/kHz to 5 kHz
AC Noise Level >60 dB rms below full output voltage
Amplitude Stability 

With Remote Sense
±0.1% of full scale over 24 hours at constant line, load and temperature
Line Regulation (DC, or 40 Hz to 5 kHz): ±0.015% of full scale for a ±10% input line change
Load Regulation ±0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add ±0%/kHz
Voltage Accuracy ±0.1% of range. Above 1 kHz, add 0.2%/kHz. Add ±0.1% of full scale for "AC PLUS DC" mode. Valid for 5 to 156 Vrms and 10 to 312 Vrms at 25°C
Voltage Resolution 1mV (0.1V) Full Scale
Frequency Accuracy ±0.01% at 25°C ±0.001%/°C
Frequency Resolution 40 Hz to 81.91 Hz (0.01 Hz)

81.90 Hz to 819 Hz (0.01 Hz)

820 Hz to 5000 Hz (1 Hz)
Phase Accuracy, 

Phase-to-Phase Balanced Linear Resistive Load
±1% of Programmed value
Phase Angle Resolution 0.1°
Remote Output Voltage Sense 5 Vrms total lead drop, max
Common Intput and Outputs
Remote Inhibit A logic Low or High contact closure input to inhibit the outputs
External Amplitude Modulation 0 to 5 VRMS provides 0 to 20% output amplitude modulation (±2% of full scale output).
External Drive Input Acts as Amplifier, 0 to 5 VRMS (DC to 5 kHz) or ±5 VDC input for zero to full scale programmed voltage output (±2% of full scale output). Individual inputs for an external signal for each of the three phases.
Remote Programming Voltage 0 to ±7.07 VDC provides zero to full scale programmed voltage output

(±2% of full scale output).
External Input Impedance 40K (ohm symbol) for each of the three inputs.
Externaly Sync External Sync allows the output frequency of the AC source to be synchronized to an external TTL level clock signal.
LKM Clock and Lock Master. Enables synchronizing outputs of two or more California Instruments sources, one acts as master.
LKS Clock and Lock Auxiliary
Front Panel Trigger, BNC Connector Output available at the front panel BNC connector that provides a negative going pulse for any programmed voltage or frequency change. The trigger can be reassigned as an output when running list transients.
Front Panel Phase A, B and C, BNC connectors These three outputs are representive of the programmed output waveform, magnitude and frequency. 0 to 4.86 Vrms represents 0 to a full-scale output voltage.
Environmental
Operating Temperature 0°C to 45°C (32°F to 113°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Cooling Air is drawn in from the top, bottom, and sides and exhausted through the rear
Humidity (Non-condensing) 0 to 85% at 25°C (77°F); derate to 50% at 40°C (104°F)
Altitude Operating 10,000 ft, non operating 40,000 ft
Physical
Dimensions Width: 19" (483 mm)

Height: 8.75" (222 mm)

Depth: 23.5" (597 mm)
Weight CSW 5550 - 127 lbs (57.5 kg)
Shipping Weight - US CSW - 160 lbs (72 kg)
Note: Multi Chassis systems, dimension and weight are approximately x2, x3, x4 x5 and x6 CSW Specifications
Measurements - Standard (AC Measurements)
Parameter Frequency Phase Voltage (AC rms) Current (AC rms)
Range 40-81.91 Hz

82.0-819.1 Hz

> 819 Hz
40-100 Hz

100-1000 Hz
0-300 V 0-50 A
Accuracy* (±) 

1 ø mode (-1)
0.1% + 1 digit 0.5° 0.5% + 250 mV 0.1% + 150 mA
Accuracy* (±) 

3 ø mode (-3)
.01 Hz / 0.1 Hz / 1 Hz 0.5% + 250 mV 0.1% + 50 mA
Resolution* .01 Hz / 0.1 Hz / 1 Hz 0.1° / 1° 10 mV 1 mA
Parameter Real Power Apparent Power Power Factor
Range 0-6 kW 0-6 kVA 0.00-1.00
Accuracy* (±) 1 ø mode (-1) 0.15% + 9 W 0.15% + 9 VA 0.03
Accuracy* (±) 3 ø mode (-3) 0.15% + 3 W 0.15% + 3 VA 0.01
Resolution* 1 W 1 VA 0.01
* Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms.
Harmonic Measurements
Parameter Range Accuracy ( ± ) Resolution
Frequency fundamental 40.00 - 1000 Hz 2 counts 0.01 Hz to 1 Hz
Frequency harmonics 32.00 Hz - 16 kHz 2º typ. 0.5º
Voltage Fundamental 0.25V 0.01V
Harmonic 2 - 50 0.25V + 0.1% + 0.1%/kHz 0.01V
Current Fundamental 0.05A 0.01A
Harmonic 2 - 50 0.05A + 0.1% + 0.1%/kHz 0.01A
Harmonics frequency range in three-phase mode is 32 Hz - 16 kHz. Accuracy specifications are multiplied by the number of power sources in multi-source systems with the 3-phase (3Ø) or the number of sources times 3 in the 1-phase (1Ø) mode . Measurement bandwidth is limited to 16 Khz.
Model CSW5550 CSW11100 CSW16650
Multiplier 3Ø/1 Ø 1/3 2/6 3/9
Model CSW22200 CSW27750 CSW33300
Multiplier 3Ø/1 Ø 4/12 5/15 6/18
Protection And Safety
Overvoltage Shutdown Programmable for 15V to 255V peak, 156V range; 30V to 510V peak, 312V range
Programmable Current Limit Shutdown Settable to 0.01 ARMS Resolution
Programmable Current Limit 

with Timed Shutdown
Settable to 1% of range: the timeout is settable from 100 ms to 10s.
Over temperature Shutdown Automatic, not programmable
Regulatory Compliance
  • EN 61010
  • EN 55011
  • UL 3111
  • EN 50082-2
  • EN 61000-4-3, EN 61000-4-4
  • FCC Part 15, Class A
  • CE Mark
  • Designed to meet:
    • ​EN 61010
    • EN 55011
    • UL 3111
    • EN 50082-2
    • EN 61000-4-3, EN 61000-4-4
    • FCC Part 15, Class A

More Product Information

AMETEK Programmable Power

Located in San Diego, California, AMETEK Programmable Power designs, manufactures, and markets precision, AC and DC programmable power supplies, electronic loads, application specific power subsystems, and compliance test solutions for customers requiring and valuing differentiated power products and services. Also part of our business is VTI Instruments, which delivers precision modular instrumentation and systems for electronic signal distribution, acquisition, and monitoring, used in the world's most demanding test applications. 

AMETEK Programmable Power boasts one of the industries' broadest portfolios of programmable power products under the well-known and respected Sorensen, Elgar, and California Instruments brands. AMETEK Programmable Power’s products serve a wide range of stimulus (T&M) and process power needs in applications including semiconductor fabrication, commercial and defense ATE, oil exploration, solar array and battery string simulation, avionics, general R&D and EMC compliance testing. 

VTI Instruments provides products and systems which are used to monitor and record data that characterizes the physical integrity and performance of aircraft, engines, and other large structures, as well as automate the functional testing of complex electronic systems. VTI Instruments is recognized as an industry leader with a reputation of providing reliable data, first time, every time. 

With strong brands, a broad product portfolio, exceptional precision power conversion and control expertise, proven power system integration capabilities and deep applications knowledge, AMETEK Programmable Power is your source for programmable power supplies, precision data acquisition instruments, and more.


Contact Details 

AMETEK Programmable Power, Inc. − San Diego 

9250 Brown Deer Road, San Diego, CA 92121, USA

Phone: 858-450-0085 

Fax: 858-458-0267 

Email: sales.ppd@ametek.com for general inquiries

Contact form

Test & Measurement

Download Line Card
California Instruments - CSW Series 5550 - 33300VA High Performance Programmable AC and DC Power Source
California Instruments - CSW Series 5550 - 33300VA High Performance Programmable AC and DC Power Source
California Instruments - CSW Series 5550 - 33300VA High Performance Programmable AC and DC Power Source
California Instruments - CSW Series 5550 - 33300VA High Performance Programmable AC and DC Power Source