IntelliPower - FA00175-01 External Battery Module
-
2U Fixed EBM with Lead Acid Batteries
TYPE | SPECIFICATION |
---|---|
Chassis Configuration | 2U, ≤23"D |
Output Connector | Circular Mil |
Battery Runtime | ≥ 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Fixed |
More Product Information
-
2000VA, 1500W, 120/240VAC 50/400Hz Input and 120VAC 60Hz Output, Double Conversion, On Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
2500VA 1800W, 115VAC 3Ph, 400Hz Input and 115VAC (300W) 28VDC (1500W) Output UPS
-
500VA, 350W, 115VAC 60Hz Isolated Input, 115VAC 60Hz Output, Freq Changer, 4LBHS (8.5Ah) & EBP, 3U12, SNMP, 2 x 2 Anderson EBP, Double Conversion, Rugged, High Temperature, On‐line UPS with Hot Swap Battery Drawer and Power Factor Correction
-
5000VA, 4000W, 120VAC 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, Extreme High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
625VA, 500W, 110/220VAC, 50/60Hz input and 110VAC 60Hz Output UPS w/power factor correction (PFC)
-
Double Conversion, Rugged, High Temperature, Isolated, On Line UPS in 3U-20.63”D Rack Mountable Enclosure with Power Factor Correction, Cold Start, SNMP, 120VAC, 50/60Hz Input and 120VAC, 60Hz Output
-
3000VA, 2400W, Isolated 208VAC Single Phase 50/60Hz Input and 120VAC, 60Hz Output, Double Conversion Input On Line UPS and Power Conditioning System with Internal Batteries and Power Factor Correction for Commercial Applications
-
2000VA, 1800W, 120/240VAC & 28DC Input & 120VAC, 60Hz Output, Double Conversion, Rugged, High Temperature, Isolated On-Line UPS System with Hot Swap Battery, Frequency Conversion, Power Factor Correction and SNMP Communications
-
3000VA, 2500W, 115Vac 400Hz 3 Phase, 12 Pulse Isolated Input, 28Vdc Output, Freq Changer, No Battery, 3U23.98, Aluminum, Cir Mil, RS232, Cir Mil
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form