IntelliPower - FA00312 Frequency Converter
-
6000 VA, 6000 W, 74 VDC Input and 2 isolated independent 120 VAC at 60Hz Outputs, Rugged Extreme Temperature Inverter
TYPE | SPECIFICATION |
---|---|
Power Rating | 150W |
Chassis Configuration | 6U, ≥24"D |
Input Voltage | 120 or 230 VAC |
Input Frequency | 50/60 |
Input Connector | Circular Mil |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | Circular Mil |
Communication | None |
More Product Information
Our RF horn antennas exhibit increasing gain, with frequency up to 18 dBi at 1000 MHz, helping to compensate for losses that occur elsewhere in an RF test system. Use these antennas in shielded rooms or free space.
-
3500 VA, 3000 W, 115 VAC at 50 or 60 Hz input and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with external EBM, with power factor correction for Navy shipboard applications
-
6KVA, 5.0KW Double Conversion, On-Line, Isolated 440V 3-Ph. Delta Input, 60Hz Input UPS with 440V 3-Ph, 60Hz Output UPS
-
1500VA, 1400W High Temperature Double Conversion On Line IPS with 120VAC, 60Hz Input, 120VAC and Thee DC Outputs, Input Power Factor Correction for Highly Rugged Military
-
1500VA, 1000W AC, 120 or 240VAC 50/60Hz Input and 120VAC 50/60Hz Output, Double Conversion On-Line UPS WITH (1) 20S2P LiFeO4 battery pack Hot Swap Drawer, one inch ground stud mounted on the rear of the unit for multi-unit grounding, and Power Factor Correction
-
1500VA, 1050W, 120VAC 45-450Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, High Temperature, Isolated, Rugged IPC with Power Factor Correction for Military Applications
-
3100 VA, 3100 W, 2 ea. 115 VAC at 60 Hz input with automatic transfer failover and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with optional EBP, with power factor correction for Navy shipboard applications
-
3000VA, 2.1KW, 115 VAC 50/60 Hz Input, 115 VAC, 60 Hz Output, Frequency Changer, Galvanic Isolation, Power Factor Corrected, Rack Unit, 3U High x 19" Wide x 16.75" Deep, Strain Relieved Power Cables, Rugged, Double Conversion UPS, to Provide Power Conditioning and Battery Hold-up for Shipboard Applications
-
Three-phase, 440 VAC at 60 Hz Input, Isolated, Double Conversion Rugged Frequency Converter with 2000 Watts at 24 VDC output to provide Power Conversion and Power Conditioning
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form