IntelliPower - FA00375 External Battery Module
-
External Battery Pack w/ 2 strings of 7 Batteries (14 Total) in 2-24” D Enclosure
TYPE | SPECIFICATION |
---|---|
Chassis Configuration | 2U, ≥24"D |
Input Connector | IEC320 |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Fixed |
More Product Information
-
3000VA, 2400W, Isolated 208VAC Single Phase 60Hz Input and 120VAC, 60Hz Output, Double Conversion Input On-Line UPS and Power Conditioning System with Internal Batteries and Power Factor Correction
-
Rugged, Double Conversion, High Temperature, Isolated 120VAC Input & 120VAC Output On Line UPS System with Power Factor Correction for Industrial Applications
-
3000Va, 2200W, 120/240Vac 45-450Hz Global Isolated & 24Vdc Input, 120Vac 60Hz Output, Freq Changer, 8BLiFeHS, 4U21, L6-30P, L5-30R, Cir Mil DC, SNMP, w/ Anderson EBP
-
IntelliPower Breaker Distribution Panel with a 100 amp rating, for power distribution from customer generator to UPS Inputs
-
Manufactured for Military, Industrial and Commercial applications
-
2500VA, 2000W, 115VAC 60Hz Input and 115VAC 60Hz Output, Double Conversion, Rugged, On-Line UPS with Power Factor Correction for Military Applications
-
6000VA, 4500W, 85-265VAC, 50/60Hz Input and 220 or 230VAC, 60Hz Output, Freq Changer, 3U25.6, Hubbell IEC 60309 460P12W on 3ft Cord, L6-30R on 3ft Cord, Double conversion, Rugged, High Temperature, Isolated, On-line UPS, Power Factor Correction, External EBM
-
Wide Range 85 to 270 VAC, 50/60 Hz Isolated Input, 2500 VA, 2000 W Double Conversion, On Line, Light-Weight UPS with 120 VAC, 60 Hz Output and a 7 Lithium Iron Phosphate Hot Swap Battery Drawer - 4U, 20” Deep
-
1500VA, 1000W, Dual Primary and Backup 115VAC, 50/60Hz Input and 115VAC 50/60Hz Output, Double Conversion Rugged On-Line UPS with Power Factor Correction for Military Applications
-
1500VA, 1000W AC, 120VAC, 50/60Hz Input and 120VAC 50/60Hz Output, Double Conversion On-Line, High Temperature, Lithium Iron Phosphate Battery Hot Swap Drawer, Rugged UPS with Power Factor Correction
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form