PowerGridm - PG BXM – Spare Battery Module 24 VDC – Mobile Shelter UPS

PowerGridm - PG BXM – Spare Battery Module 24 VDC – Mobile Shelter UPSPowerGridm - PG BXM – Spare Battery Module 24 VDC – Mobile Shelter UPS
  • Hot Swap Lithium Iron Phosphate (LIP) Cold PakTM design.
  • Exhibits less than 10° rise over ambient on full discharge.
  • Weights less than 8 Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.
  • Can be used in either the PG-BXM24 or the PG-BXM-BPM24 units

More

Is a 24 VDC Battery Pack and is Comprised of a Set of Lithium Iron Phosphate Battery Components That Are Configured Into a Unique Low Resistance Battery Cell and the Associated Power Management Circuits. Mobile Shelter UPS

Each battery module is equipped with front panel LEDs to provide battery status to include Power On, Charging, and Discharge states. The battery module includes a battery disconnect protection circuit that removes the battery from all circuit connections when not in use. This circuit disconnect removes all discharge paths to allow the battery to maintain its charge for storage and protects the battery module from slow micro volt discharging which can damage the battery chemistry.

MIL STD 461 UPS | MIL STD 810 UPS
EMI / EMC – PowergridM UPS system has been designed to comply with all the radiated emissions, susceptibility and conductive emissions requirements of the applicable sections of MIL STD 461F. The following is a list of methods used for controlling emissions: RE102 | CE102 | CS101 | CS114 | CS115 | CS116 | RS103
Environmental MIL-STD-810G: Humidity, Altitude, Sand and Dust, Shock and Vibration, Temperature.

More Product Information

Powergridm - PG800 UPS Spare Battery Module 24 VDC – Mobile Shelter UPS
  • Hot Swap Lithium Iron Phosphate (LIP) Cold Pack design.
  • Exhibits less than 10° rise over ambient on full discharge.
  • Weights less than 3Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.

Powergridm - PG1500 – Spare Battery Module 48 VDC – Mobile Shelter Uninterruptible Power Supply
  • Hot Swap Lithium Iron Phosphate (LIP) Cold PakTM design.
  • Exhibits less than 10° rise over ambient on full discharge.
  • Weights less than 8 Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.

Powergridm - PG3000 – Spare Battery Module 48 VDC – Military Battery Backup System
  • Hot Swap Lithium Iron Phosphate (LIP) Cold PakTM design.
  • Exhibits less than 10° rise over ambient on full discharge.
  • Weights 15 Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.

PowerGridm - PG1000 – Spare Battery Module 48 VDC
  • Hot Swap Lithium Iron Phosphate (LIP) Cold PakTM design.
  • Exhibits less than 10° rise over ambient on full discharge.
  • Weights less than 5 Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.

Powergridm - PG BXM – Spare Battery Module 48 VDC – UAV Flight control UPS
  • Hot Swap Lithium Iron Phosphate (LIP) Cold PakTM design.
  • Exhibits less than 10 degrees temperature rise over ambient on full discharge.
  • Weights less than 16 Lbs.
  • Embedded Power Management and Charging Circuitry.
  • Conservatively rated at a minimum of 2500 full Charge/Discharge cycles.
  • Rated at 5 to 10 years shelf line for stored modules.
  • Can be used in either the PG-BXM48 or the PG-BXM-BPM48 units.

PowerGridm - Battery Expansion Module 48 VDC Output – Military Battery Backup System UPS
  • Connects to any 1500/3000 UPS via VDC Input Connector.
  • Replicates the UPS VDC Input Power Connector for DC power source.
  • Hosts 1 removable Cold Pack Battery tray each containing 8 PowergridM battery modules.
  • Provides LED Operational Status Indicators for each battery tray.
  • Same physical 1U size chassis as the PowergridM 1500 VA UPS.
  • Each BXM provides a minimum of 30+ minutes (Model Dependent).

PowerGridm - Battery Expansion Module – BackPlane 48 VDC Output – Military Battery Backup System UPS
  • Plugs into any available slot in the BPM BackPlane.
  • Hosts 1 removable Cold Pack Battery tray each containing 8 PowergridM battery modules.
  • Provides LED Operational Status Indicators for each battery tray.
  • Same physical 1U size chassis package as the PowergridM UPS.
  • Each BXM provides a minimum of 24+ minutes of hold time.

PowerGridm - Battery Expansion Module – BackPlane 24 VDC / 28 VDC Output – Military Battery Backup System
  • Connects to any available slot in the BPM.
  • Hosts 2 removable Cold PakTM battery trays each containing 3 PowergridM battery modules.
  • Provides LED Operational Status Indicators for each battery tray.
  • Same physical 1U size chassis package as the PowergridM UPS.
  • Each BXM provides a minimum of 27+ minutes of extended power.
  • MIL-STD 1275 compliant for VDC charging of batteries.

PowerGridm - Battery Expansion Module 24 VDC / 28 VDC
  • Connects to any PowergridM 800 UPS via VDC Input Connector.
  • Replicates the UPS VDC Input Power Connector for DC power source.
  • Hosts 2 removable Cold PakTM battery trays each containing 3    PowergridM battery modules.
  • Provides LED Operational Status Indicators for each battery tray.
  • Same physical 1U size chassis package as the PowergridM 800 UPS.
  • Each BXM provides a minimum of 27+ minutes of extended power.
  • MIL-STD 1275 compliant for VDC charging of batteries.