Teledyne LeCroy - WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes 4 GHz–30 GHz

  • Up to 30 GHz bandwidth and 80 GS/s sample rate
  • The most advanced oscilloscope user interface
  • The industry’s only true hardware 14.1 Gb/s serial trigger
  • Low Jitter Measurement Floor and exceptional timebase stability
  • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
  • Integrated standard and custom measurements and math functions for unrivaled analysis capability
  • Multi-lane serial data eye, jitter and crosstalk analysis
  • Real-time de-embedding, emulation, and equalization

Main Specifications

Bandwidth 4 GHz - 30 GHz
Starting from $81,400
Standard Memory 32 Mpts - 512 Mpts
Max Memory 512 Mpts
Max Sampling Rate 80 GS/s
Input Channels 4
Resolution 8-bit

WaveMaster 804Zi-B   (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 4 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 806Zi-B   (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 6 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 808Zi-B   (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 8 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 813Zi-B   (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 13 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 816Zi-B   (16 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 16 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 820Zi-B   (20 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 20 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

WaveMaster 825Zi-B   (25 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 25 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 512 Mpts/Ch (2 Ch operation)
Input Channels 4 @ 20 GHz

2 @ 25 GHz
Vertical Resolution 8-bits

WaveMaster 830Zi-B   (30 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 30 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 512 Mpts/Ch (2 Ch operation)
Input Channels 4 @ 20 GHz

2 @ 30 GHz
Vertical Resolution 8-bits

SDA 804Zi-B   (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 4 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 806Zi-B   (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 6 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 808Zi-B   (8 GHz Bandwidth, 4 Input Channels, 32 GS/s Max Sample Rate)

 
Bandwidth 8 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 813Zi-B   (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)

 
Bandwidth 13 GHz
Sample Rate 40 GS/s

(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 816Zi-B   (16 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 16 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 820Zi-B   (20 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 20 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 256 Mpts/Ch
Input Channels 4
Vertical Resolution 8-bits

SDA 825Zi-B   (25 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 25 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 512 Mpts/Ch (2 Ch operation)
Input Channels 4 @ 20 GHz

2 @ 25 GHz
Vertical Resolution 8-bits

SDA 830Zi-B   (30 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)

 
Bandwidth 30 GHz
Sample Rate 40 GS/s on 4 Ch

80 GS/s on 2 Ch
Maximum Acquisition Memory 512 Mpts/Ch (2 Ch operation)
Input Channels 4 @ 20 GHz

2 @ 30 GHz
Vertical Resolution 8-bits

More Product Information

Teledyne LeCroy

Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively. 

Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. Protocol analyzers are tools used by designers and engineers to generate and monitor traffic over high speed serial data interfaces, including DDR, PCI Express, Fibre Channel, Serial ATA, SAS, USB and others. Both products are critical in the development of a wide variety of demanding design applications. 

We utilize both of these important product areas in combination to tackle the most demanding serial data test applications, offering tailored solutions to help our customers perfect their chips, interfaces, subsystems and products which utilize these important communications standards. With the explosion in the use of serial data communications technologies in semiconductors, between devices on circuit boards and between computers and peripherals, we are aimed at a growing and important market. 

Our oscilloscopes offer a powerful combination of large and informative displays combined with advanced waveshape analysis capabilities typically tailored to enhance the productivity of engineers in specific applications areas such as serial data test, disk drive test and automotive bus analysis. 

Headquartered in Chestnut Ridge, New York, LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, military/aerospace, automotive/industrial, and telecommunications.


Contact Details 

Headquarters Teledyne LeCroy  

700 Chestnut Ridge Road, Chestnut Ridge, NY 10977-6499, USA

Phone: 800-553-2769 or 845-425-2000 

Phone Support: 1-800-553-2769 

Fax Sales: 845-578-5985 

Email Sales: contact.corp@teledynelecroy.com

Email Support: support@teledynelecroy.com (Oscilloscopes, Waveform Generators, Signal Integrity) 

Contact forms

Test & Measurement

Download Line Card
Teledyne LeCroy - WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes 4 GHz–30 GHz