  • FG410: 1 channel. FG420: 2 channel
  • Output waveforms: Sine, Square, Pulse, Ramp, Parameter-variable waveform, noise, DC, and Arbitrary waveforms
  • Frequency range: Sine wave 0.01 µHz to 30 MHz
  • Amplitude resolution: 16 bits
  • Sampling rate: 120 MS/s
  • Output: 0 to 20 Volts, peak-to-peak
  • Synchronize up to 6 units to provide up to 12 output channels
  • GPIB and USB Interface
  • Generate waveforms acquired by Yokogawa's ScopeCorder and DL Series Oscilloscopes with XviewerLITE software
  • Warranty period for this instrument is 3-years

More

The FG400 easily generates basic, application specific and arbitrary waveforms with a sine wave frequency range of .01 µHz to 30 MHz.  Output waveforms consist of Sine, Square, Pulse, Ramp, Parameter-variable, Noise (Gaussian distribution), DC and Arbitrary.  This unit includes isolated outputs that allow the user to use it in the development of floating circuits, like motor drives, inverters, power supplies and other power electronic devices.  In addition, multiple units can be synchronized together to generate up to 12 phases of output.

More Product Information

Yokogawa - 701947 Isolated Probe 1000V / 200 MHz
Passive Probe, 3540Vp-CAT I, 1000Vp-CAT II, 200MHz, 100:1, 100MΩ, 1.5m, 'Isolated Probe' 'Iso-Probe'. For use with 701250, 701251, 701260, 701280, 701281, 720210 isolated-input modules ONLY. For use with DL850 series, DL750/DL750P, SL1400, and SL1000. Not for use with CAT III or CAT IV measurements

Yokogawa - 702902 Isolated Passive Probe 1000V / 60 MHz
  • Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m, 'Isolated Probe' 'Iso-Probe'.
  • For use with 701250, 701251, 701267, 701280, 701281, 720210 isolated-input modules ONLY.
  • Not for use with CAT III or CAT IV measurements

Yokogawa - 700929 Isolated Passive Probe 1000V / 100 MHz
Passive Probe, 1000Vp CAT2, 100MHz, 10:1, 10MΩ, 1.5m, Isolated Probe, Safety Iso-Probe. For use with 701250, 701251, 701260, 701280, 701281, 720210 isolated-input modules ONLY. For use with DL850 series, DL750/DL750P, SL1400, and SL1000. (This is the "new style" 700929 Iso-Probe for ScopeCorder.)

Yokogawa - 700987 Logic Probe for the DL750 -  Isolated Inputs
  • 8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), treshold level 6VDC or 50VAC.
  • To be used with measurement lead 758917 and 758922, 758929 or 701954 adapter leads.

VTI Instruments - EMX-7515 64 DI, 60 V MAX, Isolated Static I/O
  • Static digital input/output
  • 64 channels total (8 ports of 8 bits each), bidirectional
  • High current (300 mA), on each channel
  • Voltage inputs and outputs from 2 V to 60 V on each channel
  • Embedded soft front panel interface
  • Common IVI software drivers available
  • Multiple digital logic levels: LV TTL, TTL
  • Optical isolation at 1000 V

VTI Instruments - EMX-7514 64 DO, Source/Sink, 60 V MAX, Isolated Static I/O
  • Static digital input/output
  • 64 channels total (8 ports of 8 bits each), bidirectional
  • High current (300 mA), on each channel
  • Voltage inputs and outputs from 2 V to 60 V on each channel
  • Embedded soft front panel interface
  • Common IVI software drivers available
  • Multiple digital logic levels: LV TTL, TTL
  • Optical isolation at 1000 V

VTI Instruments - EMX-7513 32DI/32DO, Source/Sink, 60 V MAX, Isolated Static I/O
  • Static digital input/output
  • 64 channels total (8 ports of 8 bits each), bidirectional
  • High current (300 mA), on each channel
  • Voltage inputs and outputs from 2 V to 60 V on each channel
  • Embedded soft front panel interface
  • Common IVI software drivers available
  • Multiple digital logic levels: LV TTL, TTL
  • Optical isolation at 1000 V

VTI Instruments - EX1401 16-Channel Isolated Thermocouple and Voltage Measurement Instrument
  •  Typical accuracies of ±0.20°C
  • 16-channel isolated universalt hermocouple/voltage inputs
  • Power over Ethernet (PoE)
  • 20K samples/second/channel sample rate
  • 24-bit ADC per channel
  • 500 V channel-ground isolation
  • 1000 V channel-channel isolation
  • Data logger acquisition mode
  • Built-in parallel data streaming
  • Full-featured embedded web interface
  • LXI Ethernet interface
  • 8-bit bank isolated digital I/O
  • Compact 1U half-rack form factor

Teledyne LeCroy - HVFO High Voltage Fiber Optically-isolated Probe
  • Applications
  • Upper-side gate drive signal measurements
  • Floating control signal or sensor voltage measurements
  • EMC, EFT, ESD, and RF immunity testing and system optimization
  • Any small signal measurements with high common-mode voltage
  • 60 MHz bandwidth
  • 35 kV common-mode voltage rating (fiber optic isolation)
  • Superior Noise and Rejection
    • 140 dB CMRR
    • Low loop inductance
    • Low attenuation
  • Reduced DUT loading, better pulse response compared to conventional HV differential probes
  • Selectable tips from ±1V to ±40V
  • Eliminates need to “float” the oscilloscope
  • ProBus-compatible with many Teledyne LeCroy oscilloscopes