NEO X01 3000 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 601B-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-20 UNJF Class 3B |
1.67 |
0.48 |
1.45 |
|
NEO 601B-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-18 UNJF Class 3B |
1.77 |
0.49 |
1.45 |
| NEO 601B-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-16 UNJF Class 3B |
1.89 |
0.56 |
1.45 |
|
NEO 601B-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-14 UNJF Class 3B |
1.97 |
0.66 |
1.66 |
| NEO 601B-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-12 UNJ Class 3B |
2.04 |
0.70 |
1.66 |
|
NEO 601B-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-12 UNJ Class 3B |
2.32 |
0.79 |
1.92 |
|
NEO 601B-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-12 UNJ Class 3B |
- |
- |
- |
*Approximate Dimensions [inches]
More Product Information
-
On-Off power switch
-
20 A Circuit Breaker
-
Inlet - NEMA L6-20
-
Outlets – NEMA L6-20R
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
All caps ship with Skydrol (BMS3-11) Compatible O-ring Seal. Parts in compliance with all SMOT document requirements.
- 2 in 1: device contains the Hot Set Test as well as the Heat Pressure Test
- Robust and compact set including the device and an equipment case
- Possibility to attach a thermometer directly near the sample
- Measurement according to the cable standards IEC 60811 -507 (Hot Set Test) and IEC 60811 -508 (Heat Pressure Test) regarding sample attachment and weight attachment
- Precise choice of weights due to practical containers
- Simultaneous measurement of up to 3 cable or tube samples
- 600 MHz of instantaneous bandwidth per channel
- Timing synchronization up to 16 channels
- Link Emulation including:
- Phase continuous delay, Doppler, and attenuation changes
- AWGN and Eb/No
- 12 tap (path) multipath fading with Rayleigh, Rician & CW. Angle of Arrival (AOA), k-factor, and correlation controls
- RF frequency agile up/down converters
- Payload Emulation including:
- IMUX/OMUX amplitude and group delay distortion
- Amplifier Compression (AM/AM and AM/PM)
- Phase Noise
- Static and dynamic link emulation
- Ephemeris data generation using SATGEN
- Remote instrument control through ACEClient application
- Capture from legacy to the latest video sources through support for SD analog to UHD digital formats
- Connect and switch between different video sources via Mini DisplayPort, HD-BNC, HDMI, and custom analog DVI1 connectivity
- Handle multiple video sources with the simultaneous capture of up to eight HD or two UHD streams2
- Optimize video transmission and storage through onboard multi-stream H.264 encoding
- Minimize system footprint by way of a single-slot PCIe card design
- Simplify application development using the Aurora Imaging Library, formerly Matrox Imaging Library (MIL), software development kit (SDK)
- Deploy on a current platform of choice with support for 64-bit Windows® 7/10 and Linux
-
On-Off power switch
-
15 A Circuit Breaker
-
Inlet - IEC C14 for use with any cordset
-
Outlets – (8) IEC C13
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors