Dualos - Fittings - NEO 601B Series
NEO X01 3000 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 601B-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-20 UNJF Class 3B |
1.67 |
0.48 |
1.45 |
|
NEO 601B-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-18 UNJF Class 3B |
1.77 |
0.49 |
1.45 |
| NEO 601B-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-16 UNJF Class 3B |
1.89 |
0.56 |
1.45 |
|
NEO 601B-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-14 UNJF Class 3B |
1.97 |
0.66 |
1.66 |
| NEO 601B-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-12 UNJ Class 3B |
2.04 |
0.70 |
1.66 |
|
NEO 601B-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-12 UNJ Class 3B |
2.32 |
0.79 |
1.92 |
|
NEO 601B-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-12 UNJ Class 3B |
- |
- |
- |
*Approximate Dimensions [inches]
More Product Information
- Device and operation are according to the standard IEC 60811-506 (IEC 60811-1-4) point 8.5
- Case set offers all required weights for the test
- Easy operation
- Very robust and solid construction
- Steel impact piece included
- Up to 3 Samples can be tested simultaneously
- Device suitable for positioning in a cold chamber - Product No.: 402.0020.02
- Two 120/240 V Outlets
- Circuitry rated for 20 A
- 8’ Flexible Power Cord
- Shrouded Safety Banana Jacks
- Stable footprint with non-slip feet
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
With LUMIMAX® LED Coaxial Lights, a highly diffused light field is shown on the object field through a semi-transparent mirror vertical in the optical axis of the camera. The homogeneous and shadow-free lighting is used for surface inspections, completeness checks and printed image inspections. The Coaxial Lights also meet the requirements for standard-compliant reading and verification of two-dimensional codes.
The optical design of Coaxial Lights necessarily reduces the amount of light emitted. By using the latest generation of High Power LEDs, the new LES series can compensate for this effect and illuminate test objects with high light intensity.
- Robust and compact design, easy to handle
- Fast, reliable and highly accurate measuring process
- Integrated hardware and software, touch monitor for intuitive operationReliable, high-precision clamping of the test specimen (including conical tools / conical wire guides)
- The highly precise alignment of camera and test object chuck both enable a highly accurate measurement
- No extraneous light influences thanks to measuring behind closed sliding door
- Single or dual-channel display
- Agilent HP 437 & Agilent HP 438, and Boonton 4220A & 4230A emulation
- Automatically loads sensor data
- Simple software control via SCPI language
- IEEE-488 and RS-232 interfaces standard
The 4240 series of CW RF power meters provides the high speed measurement capability needed in a production environment, as well as the simplicity of operation required for bench top use. It provides very accurate measurements from -70 dBm to +44 dBm (sensor dependent) and has a rapid display update rate for tuning applications. The easy to read LCD displays both channels simultaneously with numeric and bar graph information.
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors