Maury MW - VNA Calibration Kit - Mechanical Calibration Kits Series
- Directly compatible with most commercial VNA’s
- Available as polynomial and characterized device kits
- Measure S-Parameters with uncertainty when used in conjunction with Maury’s Insight software platform
Maury offers coaxial and waveguide VNA calibration kits.
Coaxial calibration kits are offered in Polynomial SOLT, Characterized Device (CD) SOLT, and TRL, depending on the connector series. Where available, CD kits improve calibration accuracy when compared to SOLT kits based on polynomial definitions as each calibration kit is provided with individually characterized short, open and fixed load standards, whose S-parameters can be loaded into commercial VNAs directly or when used with Maury’s Insight™ software platform. When combined with Insight™, users will be able to quantify the uncertainty contribution of their calibration kit to their overall measurements. CD cal kits result in TRL-like accuracy with fixed-load SOLT ease-of-use.
|
Frequency Range (Coaxial) |
Frequency Range (Waveguide) |
Calibration Method |
Phase-Matched Adapters |
Measurement Uncertainty |
|
10 MHz to 67 GHz |
2.6 to 50 GHz |
SOLT, SSLT, TRL |
Optional |
Optional |
More Product Information
- High-level noise modules mounted on a circuit board
- Modified BW, output power, and flatness specifications
The NC2000 Series amplified noise modules are an excellent choice for high-level noise modules mounted on a circuit board. The NC2000 Series modules are housed in 24, or14-pin dual-inline packages. The NC4000 series modules are housed in a 40-pin module that cover similar noise bands to the NC2000, but have higher crest factor, and 60 dB of TTL controlled attenuation. Modified BW, output power, and flatness specifications are available for these modules. Please consult Noisecom for availability, and appropriate package style.
- Automatic calibration for the whole test frequency range
- Application of all test frequencies automatically. The level can be selected or automatic.
- NO need to manually configure the measurement equipment
- NO need to manually integrate the transfer function of probes and attenuators
- Generation of test reports: NO need to record all values read from the measurement equipment
- Generation of calibration reports: NO need to record all calibration setting parameters
- Rack together and add CS101, CS109, and RS101 (sections 18, 19, and 20 of the RTCA DO-160G are also available.)
- AWGN as high as +13 dBm
- Bandwidths up to 18 GHz
- Bandwidth, output power, and flatness can be modified for specific applications
- TTL controlled attenuation
The NC1000 Series amplified noise modules produce AWGN as high as +13 dBm, and have bandwidths up to 18 GHz. The high power modules are designed to test noise immunity for Cable TV equipment, secure communication channels, and military jamming systems. The lower power modules, <= 0 dBm, are random jitter sources for many applications including, PCIexpress, Infiniband, and 10 GigE. The Bandwidth, output power, and flatness can be modified for specific applications. A newly developed TTL controlled attenuation feature is also available.
- Directly compatible with most commercial VNA’s
- Available as polynomial and characterized device kits
- Measure S-Parameters with uncertainty when used in conjunction with Maury’s Insight software platform
Maury offers coaxial and waveguide VNA calibration kits.
Coaxial calibration kits are offered in Polynomial SOLT, Characterized Device (CD) SOLT, and TRL, depending on the connector series. Where available, CD kits improve calibration accuracy when compared to SOLT kits based on polynomial definitions as each calibration kit is provided with individually characterized short, open and fixed load standards, whose S-parameters can be loaded into commercial VNAs directly or when used with Maury’s Insight™ software platform. When combined with Insight™, users will be able to quantify the uncertainty contribution of their calibration kit to their overall measurements. CD cal kits result in TRL-like accuracy with fixed-load SOLT ease-of-use.
- Vector Network Analyzer Frequency Range from 10 MHz up to 3.2 GHz
- Spectrum Analyzer Frequency Range from 9 kHz up to 3.2 GHz
- -156 dBm/Hz Displayed Average Noise Level (Typ.)
- -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
- Total Amplitude Accuracy < 1.2 dB
- 1 Hz Minimum Resolution Bandwidth (RBW)
- All-Digital IF Technology
- Standard Preamplifier
- Distance to fault capability using VNA time domain analysis
- Up to 1.5 GHz Tracking Generator Kit
- Built-in Advanced Measurement capability (CHP, ACPR, OBW, CNR, TOI, etc)
- 10.1 lnch WVGA (1024 x 600) Display
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
A precision fixed termination (or load) consists of an immovable, (fixed) termination which, when mated to the end of a trans-mission line or cable, absorbs nearly all of the signal energy traveling toward it. An ideal “matched” condition exists when a termination with an impedance value of Z0, is connected to the end of a transmission line or cable that also has a characteristic impedance of Z0. Such an ideal “matched” condition (one with no mismatch between the termination and its mated line or cable) is critical if a voltage standing wave ratio (VSWR) of 1.0:1 is to be achieved in a system with a 50 or 75 ohm impedance value. Simply put, the more closely the 1.0:1 ratio is approached, the more accurate the measurements that can be made from a system.
- Custom electrical testing available upon request
- Wide package variety with custom configurations
- NC100 & 200 series for audio and RF applications
- NC300 & 400 series for microwave application
Noise diodes are the fundamental building blocks for analog noise systems. They are categorized for performance characteristics that enhance their broadband noise output and flat spectral response. All Maury noise diodes can deliver symmetrical white Gaussian noise and flat output power versus frequency*.
* Flatness and output power are dependent upon peripheral circuit characteristics
- Ultra-low distortion signal path
- Standard connectors SMA female
- 7” touch screen display
- Dimensions: 17.22 in. wide x 6.30 in. including feet, high x 19.5 in. deep
- Fold-down feet for bench top use
- Power 115 VAC, 60 Hz
- Operating Temperature: -10° to +65°C
- Differential inputs and outputs
- Multiple differential inputs and outputs
- Real-Time Full Bandwidth Data Acquisition
- Versatile – Reconfigurable Front End
- Measure: PM / AM / Baseband / Spurious / Jitter
- Isolated AM / PM
- Automated Residual Measurements
- Outstanding Accuracy
The HA7163A is a heterodyne downconversion system that is designed to seamlessly integrate with Holzworth’s real time phase noise analysis products as a calibrated frequency extension. The HA7163A provides for both absolute and residual (additive) measurements to 50GHz, making it the only solution available on the market for taking accurate additive phase noise measurements at frequencies of greater than 18GHz, without using external mixers.
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.