MVG - EMC Absorbers - Ferrite tiles
MVG supplies a range of ferrite tiles for EMC test chambers where space is limited. Ferrite tiles complement or subtitute pyramidal absorbers to save space in the anechoic chamber.
|
Solution For |
|---|
|
Hybrid solution with MVG UH-series absorber |
|
EMC/EMI Chambers |
|
Mixed-use test facilities |
|
Low frequency testing |
|
Pre-compliance & full compliance testing |
|
Key Features |
|---|
|
Excellent broadband performance |
|
Impedance match with MVG UH-series absorbers |
|
100 mm x 100 mm x 6.7 mm |
|
Includes center hole |
More Product Information
Our reverberation chamber is particularly suited for immunity testing for EMC measurement and special applications for very high-field strength applications (200V/m - 7000V/m). The paddle system ensures that the widest range of frequencies and particularly low frequency performance is maximized. This system meets testing requirements of the IEC61000-4-21 EMC testing specification.
- Capability:
- Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
- Spatial scan time:
- Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
- Spectral scan time:
- 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
- EMViewer Software
- We recommend you use the EMViewer software for best results. A Yearly subscription or a once-off purchase is available.
- Supported operating systems:
- Windows 10®
- Supported CAD overlays:
- Standard Gerber© RS274x format and HPGL format
ULTRA UH series polypropylene based hybrid electromagnetic EMC absorbers are the latest technology for EMC/RF test applications.
The polypropylene material has a highly uniform carbon density throughout the material, which provides for more predictable results with no discontinuities.
Its unique technology is a critical factor in achieving the highest electromagnetic reflectivity performance in an MVG EMC anechoic chamber.
The EH022 EMC Horn combines stable gain performance and low VSWR with wide band frequency operation. The horn is single linearly polarized with excellent cross-polar discrimination. The unique horn design suppresses any possible excitation of higher order modes in the aperture and maintains a well-defined smooth radiation pattern in the direction of the boresight axis throughout the operational bandwidth.
The TEM horn antenna is an antenna used for conducting close proximity radiation immunity evaluation test (near electromagnetic field immunity test) of electromagnetic waves radiated from various wireless transmitters such as mobile devices.
In the future, close proximity radiation immunity evaluation test using the TEM horn antenna is expected to expand to various product standards such as medical equipment (IEC 60601-1-2) and multimedia equipment (CISPR 35).NoiseKen's TEM horn antenna has a wide band, low VSWR, and wide electric field uniformity offering an ideal solution for an efficient close proximity radiation immunity test.
- A TEM horn antenna compliant with IEC 61000-4-39 Ed.1.
- Test without changing the antenna in the frequency range of 380MHz to 6GHz.
- Low VSWR and high GAIN enable efficient electromagnetic wave radiation.
- Wide field uniformity reduces the number of times of movement of the antenna when radiating the EUT.
- Since the maximum point of the near electric field distribution for each frequency is at the center, enables radiation on the EUT based on the axis of the antenna. Hence, significantly simplifies test point alignment.
The compact magnetic field generator and analyzer MGA 1033 allows susceptibility tests against magnetic fields from DC to 250 kHz according to the standard EN 55103-2 and their measurement according to EN 55103-1. In addition, EMC tests are possible according to various standards such as automotive, avionic and MIL-STD.; Generation of magnetic fields from DC to 250 kHz; Field strength up to 1000 A/m; EN 55103-1/2, MIL-STD 461, Automotive etc.; Accessories: Loop sensors, Helmholtz coils etc.;
- 1 - 6 GHz, 40dB Gain, 2.5dB N.F.
- Compensation long cable loss for EMI Measurement
- Improve system noise floor flatness
- High EMI performance
- High linearity LNA for EMI measurement
- High dynamic range
- Unconditionally Stable
- State-of-the-Art Technology
- Dual Voltage ranges that support over-voltage testing on 480V-based systems
- Separate terminal blocks for single-phase and three-phase AC power supply outputs
- High Power AC and DC Source
- Auto paralleling for higher power system expansion
- Single and three-phase modes
- Arbitrary & Harmonic Waveform Generation
- Standard LXI LAN, USB, and RS-232, Optional GPIB
- Step, list, and pulse voltage transients with down to 500usec resolution
- Complete avionics power quality test suites
- 15kVA to 1MVA Power Levels
- Intuitive 5” color display for ease of navigation
- Internationally accepted test routines for EMI/EMC, Safety Compliance
Microwave Vision Group (MVG)
Testing Connectivity for a Wireless World
The Microwave Vision Group offers cutting-edge technologies for the visualization of electromagnetic waves. With advanced test solutions for antenna characterization, radar signature evaluation and EMC, we support company R&D teams in their drive to innovate and boost product development.
Contact Details
Microwave Vision Group
1320 Air Wing Rd, Suite 101, San Diego, CA 92154, USA
Phone: 678-797-9172