Sorensen - XG 1500 - 1500 Watt, 1U Programmable DC Power Supplies

  • Industry Leading Power Density
    • Up to 1500 Watts in 1U
  • Standard Digital Interfaces – USB&RS232/485
  • LXI Ethernet and Isolated analog interfaces
  • Power Factor Correction-PFC and universal AC input
  • “Green” Sleep Mode – Automatically “sleeps” after period of non-use
  • Built in sequencing - Unload your system controller
  • Programmable fold-back protection delay

Sorensen XG 1500 Watt Specifications
Output Ratings
Model Output Voltage¹ Output Current² Output Power³
XG 6-220 6 V 220 A 1320 W
XG 8-187.5 8 V 187.5 A 1500 W
XG 12.5-120 12.5 V 120 A 1500 W
XG 20-76 20 V 76 A 1520 W
XG 30-50 30 V 50 A 1500 W
XG 40-38 40 V 38 A 1520 W
XG 60-25 60 V 25 A 1500 W
XG 80-19 80 V 19 A 1520 W
XG 100-15 100 V 15 A 1500 W
XG 150-10 150 V 10 A 1500 W
XG 300-5 300 V 5 A 1500 W
XG 600-2.6 600 V 2.6 A 1560 W
Line Regulation
Model Voltage (0.005% of rated 

output voltage +2 mV)4
Current (0.01% of rated 

output current +2 mA)5
XG 6-220 2.3 mV 24 mA
XG 8-187.5 2.4 mV 20.7 mA
XG 12.5-120 2.62 mV 14 mA
XG 20-76 3.0 mV 9.6 mA
XG 30-50 3.5 mV 7 mA
XG 40-38 4 mV 5.8 mA
XG 60-25 5 mV 4.5 mA
XG 80-19 6 mV 3.9 mA
XG 100-15 7 mV 3.5 mA
XG 150-10 9.5 mV 3 mA
XG 300-5 17 mV 2.5 mA
XG 600-2.6 32 mV 2.26 mA
Load Regulation
Model Voltage (0.005% of rated 

output voltage + 2 mV)6
Current (0.02% of rated 

output current +5 mA)7
XG 6-220 2.3 mV 49 mA
XG 8-187.5 2.4 mV 42.5 mA
XG 12.5-120 2.62 mV 29 mA
XG 20-76 3.0 mV 20.2 mA
XG 30-50 3.5 mV 15 mA
XG 40-38 4 mV 12.6 mA
XG 60-25 5 mV 10 mA
XG 80-19 6 mV 8.8 mA
XG 100-15 7 mV 8 mA
XG 150-10 9.5 mV 7 mA
XG 300-5 17 mV 6 mA
XG 600-2.6 32 mV 5.5 mA
Output Ratings
Model Output Ripple (rms, 300 kHz) Output Noise 

(p-p, 20 MHz)
Voltage Current8 Voltage
XG 6-220 8 mV 400 mA 50 mV
XG 8-187.5 8 mV 319 mA 50 mV
XG 12.5-120 8 mV 206 mA 50 mV
XG 20-76 8 mV 136 mA 50 mV
XG 30-50 8 mV 120 mA 50 mV
XG 40-38 8 mV 81 mA 50 mV
XG 60-25 8 mV 63 mA 50 mV
XG 80-19 8 mV 45 mA 80 mV
XG 100-15 8 mV 35 mA 80 mV
XG 150-10 10 mV 29 mA 100 mV
XG 300-5 25 mV 18 mA 150 mV
XG 600-2.6 50 mV 11 mA 250 mV
1. Maximum output voltage is guaranteed to be ≤ 0.2% of the rated voltage at zero output setting, using the front panel or digital remote programming modes.

2. Maximum output current is guaranteed to be ≤ 0.4% of the rated current at zero output setting, using the front panel or digital remote programming modes, and when measured with rated load resistance.

3. Total output power is also based on AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).

4. From 85–132 Vac or 170–265 Vac, constant load.

5. From 85–132 Vac or 170–265 Vac, constant load.

6. From no load to full load, constant input voltage.

7. For load voltage change, equal to the unit voltage rating, constant input voltage.

8. For 6 V models the current ripple is measured at 2–6 V output voltage and full output current. For all other models, the current ripple is measured at 10–100% output voltage and full output current.
Output Ratings
Model Maximum Recommended Remote Sense Line Drop Compensation per Line 9 Up-prog. Response Time, 0~Vmax 10 Efficiency (100/200 VAC input) 11
XG 6-220 1 V 60 ms 75/77%
XG 8-187.5 1 V 60 ms 77/79%
XG 12.5-120 1 V 60 ms 81/84%
XG 20-76 1.5 V 60 ms 82/85%
XG 30-50 2 V 60 ms 83/86%
XG 40-38 2 V 60 ms 84/88%
XG 60-25 3 V 60 ms 84/88%
XG 80-19 5 V 100 ms 84/88%
XG 100-15 5 V 100 ms 84/88%
XG 150-10 5 V 100 ms 84/88%
XG 300-5 5 V 150 ms 84/88%
XG 600-2.6 5 V 250 ms 84/88%
Output Ratings
Model Down-prog. Response Time: Full Load Down-prog. Response Time: No Load Over-Voltage Trip Point
XG 6-220 50 ms 300 ms 0.5-7.5 V
XG 8-187.5 50 ms 400 ms 0.5-10 V
XG 12.5-120 50 ms 500 ms 1-15 V
XG 20-76 50 ms 600 ms 1-24 V
XG 30-50 50 ms 700 ms 2-36 V
XG 40-38 50 ms 800 ms 2-44 V
XG 60-25 50 ms 900 ms 5-66 V
XG 80-19 80 ms 1000 ms 5-88 V
XG 100-15 100 ms 1200 ms 5-110 V
XG 150-10 150 ms 1800 ms 5-165 V
XG 300-5 150 ms 2200 ms 5-330 V
XG 600-2.6 250 ms 3500 ms 5-660 V
9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with 1 V of load line loss (0.5 V/Line), the maximum available load voltage would be 6-1=5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee That the power supply will meet performance specifications. Ultimately, the upper limit of the output voltage will be determined by internal circuitry of the power supply (non-adjustable) 

10. With rated, resistive load. 

11. At 100/200 Vac input voltage and maximum output power. Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GP1B, Ethernet optional. Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power. 

* Typical 



Note: All specifications are subject to change.
AC Line Input Specifications
Rated AC Input Voltage/Frequency 100–240 Vac, 47–63 Hz
Operational AC Input Voltage/Frequency 85–265 Vac continuous, 47–63 Hz, single phase
Input Current (at 100/200 Vac) 23/12 A
Inrush Current (100/200 Vac) Less than: 50 A
Power Factor Correction 0.99@100/200 Vac, rated output power
Programming Mode
  APG ISOL DIGITAL
Voltage & Current Output

Voltage Programming
0-100% 2~up to 10 V, programmable    
Voltage & Current Output

Resistive Programming
0-100% 2~up to 10 kΩ, programmable    
Voltage Output Resistor Programming 0-100% 2~up to 10 kΩ, programmable    
Output Voltage and Current Monitor 0-100% 2~up to 10 V, programmable    
Voltage Programming Accuracy (mV)1 ± 0.5% of rated output voltage, max (0-4V/4K range)   ± 0.1% of rated output voltage
Current Programming Accuracy (mV)1 ± 1% of rated output current,

max (0-4V/4K range)
  ± 0.2% of rated output current
Voltage Readback Accuracy (mV) ± 1% of rated output voltage   ± 0.1% of rated output voltage
Current Readback Accuracy (mV) ± 1% of rated output current   ± 0.2% of rated output current
Isolation (Prog and Readback Lines) With respect to chassis potential: 500 V With respect to:

chassis potential: 600 V

negative or positive main output 1500 V

negative or positive auxiliary output 300 V
 
Voltage and Current

Programming Resolution
    0.012% of full scale
Voltage and Current

Readback Resolution
     
Parallel Operation Up to 4 units in master / slave Up to 4 units in master / slave Up to 4 units in master / slave
Series Operation   Up to 2 units (with external diodes) Up to 2 units (with external diodes)
Constant Voltage (CV) Constant

Current (CC) Indicator
CV: TTL High (4-5 V)

CC TTL Low (0-0.6 V)
   
Shutdown Control 2   Logic low 0.0 - 1.4 V

Logic high 2.0 - 15 V

Dry contact compatible
 
AUX On/Off Control   TTL level or dry contact compatible  
Power Supply Status Signal   TTL high: OK (4-5 V)

TTL low: fail (0-0.6 V)
 
Interlock Enable/Disable   Dry contact. Open/Short: On or

Off programmable
 
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected 

2. The shutdown input has user selectable negative logic operation via front panel or remote digital input/output 



Note: All specifications are subject to change.
Output Performance Specifications
Temperature Coefficient 100 PPM/° C from rated output voltage, after a 30-minute warm-up*
Drift (8 hours) 0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up
Hold-up Time Typical 20 ms at any rated input line.
Transient Response Time 13 Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models*
Meter Accuracy 0.5% ± 1 count
Aux output 3 +5 V: +0.4 V, – 0.5 V at 0.4 A

+15 V: +1.2 V, – 1.4 V at 0.4 A
Isolation 12 1500Vac or 2121Vdc between mains terminals and accessible conductive parts / chassis ground. 

Output to chassis 500Vac.
Environmental Specifications (Indoor use)
Operating Temperature Range 32°F to 122°F, 100% load (0°C to 50°C)
Storage Temperature Range -4°F to 158°F (–20° C to 70°C)
Operating Humidity Range 30–90% RH (no condensation)
Storage Humidity Range 10–95% RH (no condensation)
Operating Altitude Up to 6,500 feet (2,000 m)
Installation Category II (IEC 1010-1)
Pollution Degree 2 (IEC 1010-1)
Mechanical Specifications
XG 1700 Watt (W×H×D) 16.8 x 1.7 x 19.0 inch (429 x 43.6 x 483 mm without rack mount ears)
Weight 22 lb (10 kg)
Cooling Forced air cooling by internal fans
Regulatory Approvals
Safety CSA 22.2 No. 61010-1, 60950-1-07 and UL61010-1, UL60950-1-(2nd Ed)12. Marked with cCSAus, CE for EMC & low voltage directive
EMC Complies with EN61326-1 

Complies with EN55022, Class B, FCC Part 15B for conducted emissions 

Complies with EN55022, Class A, FCC Part 15A for radiated emissions 

Complies with EN61000-4 series of standards for immunity

* Typical

1. Time for the output voltage to recover within 0.05% at its rated output for a load change 10-90% of rated ouput current. Output set point 10-100%

2. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective earth ground.

3. Current: 0.51 A minimum guaranteed, 0.72 A typically available. Overcurrent protection (each output) is automatic, non-latching. When OCP is tripped the aux voltage folds back and will recover to nominal condition

when the over current condition is removed (typ. <0.2A). To protect external circuits attached to the aux outputs it is recommended that customers use an appropriately rated fuse in series with the aux outputs set point 10-100%



Note: All specifications are subject to change.

More Product Information

AMETEK Programmable Power

Located in San Diego, California, AMETEK Programmable Power designs, manufactures, and markets precision, AC and DC programmable power supplies, electronic loads, application specific power subsystems, and compliance test solutions for customers requiring and valuing differentiated power products and services. Also part of our business is VTI Instruments, which delivers precision modular instrumentation and systems for electronic signal distribution, acquisition, and monitoring, used in the world's most demanding test applications. 

AMETEK Programmable Power boasts one of the industries' broadest portfolios of programmable power products under the well-known and respected Sorensen, Elgar, and California Instruments brands. AMETEK Programmable Power’s products serve a wide range of stimulus (T&M) and process power needs in applications including semiconductor fabrication, commercial and defense ATE, oil exploration, solar array and battery string simulation, avionics, general R&D and EMC compliance testing. 

VTI Instruments provides products and systems which are used to monitor and record data that characterizes the physical integrity and performance of aircraft, engines, and other large structures, as well as automate the functional testing of complex electronic systems. VTI Instruments is recognized as an industry leader with a reputation of providing reliable data, first time, every time. 

With strong brands, a broad product portfolio, exceptional precision power conversion and control expertise, proven power system integration capabilities and deep applications knowledge, AMETEK Programmable Power is your source for programmable power supplies, precision data acquisition instruments, and more.


Contact Details 

AMETEK Programmable Power, Inc. − San Diego 

9250 Brown Deer Road, San Diego, CA 92121, USA

Phone: 858-450-0085 

Fax: 858-458-0267 

Email: sales.ppd@ametek.com for general inquiries

Contact form

Test & Measurement

Download Line Card
Sorensen - XG 1500 - 1500 Watt, 1U Programmable DC Power Supplies