AMETEK RS Series High power AC and DC Power Source

  • High Power AC and DC Power Source
    • Programmable AC and DC power for frequency conversion and product test applications
  • Expandable Power Levels
    • Available output power of 90 kVA per unit and multi-unit configurations for power requirements up to 540 kVA and above
  • Arbitrary & Harmonic Waveform Generation
    • User defined voltage waveform and distortion programming
  • Regenerative, bidirectional "Green" Power Solution
    • Automatic crossover between Source and Current Sink power mode offers regenerative capabilities. Regenerate up to 100% of the rated output power back to the utility grid during sink mode operation. (-SNK option)
  • Remote Control
    • Standard RS232C & USB along with optional IEEE-488 & LAN Interfaces are available for automated test applications

California Instruments Asterion AC Series - 1U/2U High Performance Programmable AC and DC Power Sources

  • High power density in 1U/2U chassis up to 3kVA.
  • Intuitive touch panel control.
  • iX2™ current doubling technology.
  • Multi-language for global operation.
  • Auto paralleling for higher power.
  • Combine units for multi-phase configurations.
  • Complete optional avionic test suites.
  • ATE version available.

California Instruments BPS Series 30kVA - 180kVA High Power Programmable AC Source

  • High Power AC Source
    • Programmable AC power for frequency conversion and product test applications
  • Expandable Power Levels
    • Available output power of 30, 45, 75 and 90 kVA per unit and multi-unit configurations for power requirements up to 180 kVA and above
  • Remote Control
    • Standard RS232, USB and IEEE-488 (GPIB) and optional LAN interfaces are available for automated test applications.

California Instruments Compact i/iX Series 750 VA to 2250 VA, AC/DC Power Source

  • 2250 VA of AC Output Power
  • Combines AC/DC source and power analyzer
  • Harmonic analysis of Voltage and Current
  • AC, DC and AC+DC Output Modes
  • Multiple Chassis Configurations
  • Powerful output transient generation
  • High Crest Factor Capability
  • Arbitrary waveform generation
  • Single and Three Phase models available

California Instruments CS Series 3kVA - 18kVA Programmable High Power AC Current Source

  • Precision Current Source : Ideally suited for current protection device testing
  • Single and Three Phase Modes : Built-in phase mode switch makes output configuration easy
  • 3kVA to 18kVA Power Levels : Match power source & cost to application requirements
  • Arbitrary Waveform Generator : Test products using real world current profiles including harmonic currents
  • Built-In Power Analyzer : Performs voltage & current harmonic analysis & waveform acquisition
  • Standard IEEE-448, USB and RS232C : Remote control interface for ATE system integration
  • GUI Software Suite: Allows users to access the powerful features & functions of the instrument on a Windows™ system
  • Programmable Transients : Amplitude & time control with up to 1ms resolution

California Instruments CSW Series 5550VA - 33300VA High Performance Programmable AC and DC Power Source

  • Combination AC and DC Power Source
  • 40-5,000Hz Output Frequencies
  • Arbitrary and Harmonic Waveform Generation
  • Built-In Digital Power Analyzer
  • Scope Capture Capability
  • Power Programming Software
  • Constant Power Mode
  • Multi-Box Option

California Instruments i-iX Series II 3kVA - 15kVA AC/DC Power Source

  • 3000 VA to 15000 VA of AC Output Power
  • Combines AC/DC source and power analyzer
  • Harmonic analysis of Voltage and Current
  • Programmable Impedance
  • AC, DC and AC+DC Output Modes
  • Multiple Chassis Configurations
  • Powerful output transient generation
  • High Crest Factor Capability
  • Arbitrary waveform generation
  • IEC 61000-3-2 and IEC 61000-3-3

California Instruments IEC Compliance Test Systems: 1250-15000VA Programmable AC & DC Immunity Compliance Testing

  • Complete Test Solutions
    • Complete test solutions for emissions and immunity compliance testing of AC and DC powered products
  • Single & Three Phase Operation
    • Offers flexibility
  • Direct PC Bus Access
    • Provides high sampling rate and resolution for accurate measurements and high speed data transfers
  • PC based harmonic & flicker testing
    • provides real-time full color data display updates and continuous PASS/FAIL monitoring.
  • Supports Global Standards
    • Supports European and Japanese standards
  • Easy To Use Interface
    • Provides IEC test setup, data analysis, display, MS Word test reports, and data files are generated in MS Excel format
  • High resolution
    • Data storage to disk in for post-acquisition analysis and reporting
  • Single Step
    • Single Step and Fast Forward replay of recorded test data at 200 mSec

California Instruments Ls-Lx Series 3kVA - 18kVA Three Phase and Single Phase AC Power Source

Key Features Ls Series
  • Backward Compatible with L Series
    • Function and bus compatible with the California Instruments L Series
  • Three phase and Single phase modes
    • Ideally suited for avionics and defense applications
  • 3 KVA to 18 KVA Power Levels
    • Match power source and cost to application requirements
  • Transient Programming
    • Test products for susceptibility to AC line disturbances
  • Built-in Measurements
    • Performs voltage, current, and power measurements
  • Advanced Features
    • Arbitrary waveform generation, harmonic analysis, GPIB interface are some of the available options
  • Interface
    • Standard USB & RS232C interface.
    • Optional GPIB & LAN available
  • CE Marked (400V input model ONLY)
    • Safe, reliable, and consistent operation

Key Features Lx Series
  • Backward Compatible
    • Compatible with HP6834B & iL Series AC Sources Function & bus compatible with the Agilent HP6834B & California Instruments iL Series
  • Three phase and Single phase modes
    • Ideally suited for avionics and defense applications
  • 3 KVA to 18 KVA Power Levels
    • Match power source and cost to application requirements
  • Arbitrary Waveform Generator
    • Test products for harmonics susceptibility
  • Built-in Power Analyzer
    • Performs voltage and load current harmonic analysis and waveform acquisition
  • Standard IEEE-488, USB & RS232
    • Remote control interface for ATE system integration include

California Instruments MX Compliance Test System

  • Direct PC bus access data acquisition system provides the required sampling rate and resolution to meet IEC 61000-4-7 measurement requirements and supports high speed data transfers, unlike competing IEC test systems which provide only limited throughput using IEEE-488.
  • PC based Harmonic and Flicker test software provides real-time full color data display updates and continuous PASS/FAIL monitoring.
  • Automatic calculation of the maximum permissible system impedance Zsys, using the Zref and measured Flicker parameters, as required per EN/IEC 61000-3-11.
  • Simple user operation under Windows provides IEC test setup, data analysis, display and MS Word test reports.
  • High resolution, no gap acquisition data storage to ensure that all data can be streamed to disk (in ASCII format if needed) for later review and replay of actual test.
  • Single Step and Fast playback mode of test results

California Instruments MX Series 15kVA - 135kVA High Output AC/DC Power

  • High Power AC and DC Power Source
    • Programmable AC and DC power for frequency conversion and product test applications
  • Expandable Power Levels
    • Available output power of 15, 22.5, 30, and 45 kVA per unit and multi-unit configurations for power requirements up to 135 kVA and above
  • Single and Three Phase Mode
    • Phase mode programming on MX22.5-3Pi, MX30-3Pi and MX45-3Pi allows switching between single and three phase output modes
  • Arbitrary & Harmonic Waveform Generation
    • User defined voltage waveform and distortion programming
  • Regenerative, bidirectional “Green” Power Solution
    • Automatic crossover between Source and Sink power mode offers regenerative capabilities in AC mode. Regenerate up to 100% of the rated output power back to the utility grid during sink mode operation. ( -SNK option )
  • Remote Control
    • Standard RS232C & USB along with optional IEEE- 488 & LAN Interfaces are available for automated test applications

California Instruments RP Series Model 2001RP, and 2003RP

  • 2000 VA Output Power
  • Portable Power, Low Cost
  • Readback Measurements
  • Rack Mount Chassis with detachable ears
  • 16 Hz to 5000 Hz Frequency Range
  • High Peak Current Capability
  • Remote Control Option

Elgar ContinuousWave (CW) Series 800VA - 2500VA, Cost-Effective Low Profile AC Source

  • Wide range PFC Input
  • Low THD and AC noise
  • Advanced Measurement Available
  • Field Parallel Configurable
  • Multiple Units Configurable for Poly-Phase Operation

Elgar GUPS Series 1920W Ruggedized Uninterruptible Power Supply

  • Ruggedized
  • Wide (Global) Input
  • On-Line Battery Back-Up
  • Transient (Spike) Suppression
  • Surge Suppression
  • Input Distortion Elimination

Elgar ReFlex Power 875VA AC Power Source Module

  • High Power Density (2 VA/cubic inch)
  • Single or multi-phase output
  • Parallel operation
  • 4.8 Crest factor
  • Digital control loop technology
  • ≥0.95 PFC
  • Brown-out simulation
  • AC 875 VA
  • 45 to 5000 Hz
  • Universal AC/DC input via mainframe
  • User configurable
  • Simple integration

Yokogawa 2558A AC Voltage Current Standard

The 2558A AC Voltage Current Standard offers users the simple operation and reliability customers have come to trust from Yokogawa.
  • Sweep (Voltage/Current/Frequency)
  • Output Divider
  • Direct Readout of the Deviation
  • Digital Display of Output
  • Common Current Output Terminals
  • High Accuracy
  • High Stability
  • Wide Output Range
  • Wide Frequency Range
The wide output ranges of 1.00 mV to 1200.0 V AC and 1.00 mA to 60.00 A AC mean that the 2558A is the instrument of choice for the cost effective calibration of AC analog meters. Rotary controls and a range of computer interfaces enable the 2558A to be intuitively operated through the frontpanel or controlled by an ATE system.