AMREL - PLA Series Air-Cooled Programmable DC Electronic Loads

  • Broadest Model Selection: 800W to 7.5kW (higher power available up to 250kW Contact Factory)
  • Exclusive Voltage Models: 60V to 1000V
  • Multiple loads in one: Multiple ranges for voltage, current resistance and power
  • Intuitive Front Panel Control: Run sequences, triggers, constant current to constant power cross over
  • RoHS Compliant

PLA Series : Product Specifications
General
Models Power Input (MAX) Voltage (V) (MAX) Current (A) (MAX)
PLA800-60-300 800W 60 300
PLA800-120-150 800W 120 150
PLA800-400-50 800W 400 50
PLA800-600-30 800W 600 30
PLA800-800-15 800W 800 15
PLA800-1000-5 800W 000 5
PLA1.5K-60-600 1.5KW 60 600
PLA1.5K-120-300 1.5KW 120 300
PLA1.5K-400-100 1.5KW 400 100
PLA1.5K-600-60 1.5KW 600 60
PLA1.5K-800-30 1.5KW 800 30
PLA1.5K-1000-12 1.5KW 1000 12
PLA2K-60-600 2KW 60 600
PLA2K-120-400 2KW 120 400
PLA2K-400-150 2KW 400 150
PLA2K-600-100 2KW 600 100
PLA2.5K-60-1000 2.5KW 60 1000
PLA2.5K-120-600 2.5KW 120 600
PLA2.5K-400-200 2.5KW 400 200
PLA2.5K-600-120 2.5KW 600 120
PLA3K-60-1000 3KW 60 1000
PLA3K-120-800 3KW 120 800
PLA3K-400-300 3KW 400 300
PLA3K-600-150 3KW 600 150
PLA3K-800-50 3KW 800 50
PLA3K-1000-30 3KW 1000 30
PLA4K-60-1200 4KW 60 1200
PLA4K-120-1000 4KW 120 1000
PLA4K-400-360 4KW 400 360
PLA4K-600-200 4KW 600 200
PLA5K-60-1200 5KW 60 1200
PLA5K-120-1200 5KW 120 1200
PLA5K-400-400 5KW 400 400
PLA5K-600-240 5KW 600 240
PLA5K-800-100 5KW 800 100
PLA5K-1000-50 5KW 1000 50
PLA6K-60-1500 6KW 60 1500
PLA6K-120-1500 6KW 120 1500
PLA6K-400-500 6KW 400 500
PLA6K-600-300 6KW 600 300
PLA7.5K-60-1500 7.5KW 60 1500
PLA7.5K-120-1500 7.5KW 120 1500
PLA7.5K-400-600 7.5KW 400 600
PLA7.5K-600-400 7.5KW 600 400
PLA7.5K-800-150 7.5KW 800 150
PLA7.5K-1000-75 7.5KW 1000 75
General
Models CR Low (min) Ω CR High (max) Ω Vmin at Imax LxWxH & Weight
PLA800-60-300 0.0125 200 0.75 2U, 21"D
PLA800-120-150 0.0150 800 1.8 2U, 21"D
PLA800-400-50 0.0068 8000 2.7 2U, 21"D
PLA800-600-30 0.0130 20000 7.8 2U, 21"D
PLA800-800-15 0.0049 53333.3 3.9 2U, 21"D
PLA800-1000-5 0.0050 200000 5 2U, 21"D
PLA1.5K-60-600 0.0125 100 0.75 2U, 21"D
PLA1.5K-120-300 0.0150 400 1.8 2U, 21"D
PLA1.5K-400-100 0.0068 4000 2.7 2U, 21"D
PLA1.5K-600-60 0.0130 10000 7.8 2U, 21"D
PLA1.5K-800-30 0.0049 26666.7 3.9 2U, 21"D
PLA1.5K-1000-12 0.0060 83333.3 6 2U, 21"D
PLA2K-60-600 0.0100 100 0.6 3U, 25.5"D
PLA2K-120-400 0.0150 300 1.8 3U, 25.5"D
PLA2K-400-150 0.0068 2666.7 2.7 3U, 25.5"D
PLA2K-600-100 0.0140 6000 8.4 3U, 25.5"D
PLA2.5K-60-1000 0.0100 60 0.6 3U, 25.5"D
PLA2.5K-120-600 0.0150 200 1.8 3U, 25.5"D
PLA2.5K-400-200 0.0068 2000 2.7 3U, 25.5"D
PLA2.5K-600-120 0.0130 5000 7.8 3U, 25.5"D
PLA3K-60-1000 0.0100 60 0.6 3U, 25.5"D
PLA3K-120-800 0.0133 150 1.6 3U, 25.5"D
PLA3K-400-300 0.0068 1333.3 2.7 3U, 25.5"D
PLA3K-600-150 0.0120 4000 7.2 3U, 25.5"D
PLA3K-800-50 0.0031 16000 2.5 3U, 25.5"D
PLA3K-1000-30 0.0060 33333.3 6 3U, 25.5"D
PLA4K-60-1200 0.0100 50 0.6 4U, 25.5"D
PLA4K-120-1000 0.0150 120 1.8 4U, 25.5"D
PLA4K-400-360 0.0068 1111.1 2.7 4U, 25.5"D
PLA4K-600-200 0.0130 3000 7.8 4U, 25.5"D
PLA5K-60-1200 0.0100 50 0.6 4U, 25.5"D
PLA5K-120-1200 0.0150 100 1.8 4U, 25.5"D
PLA5K-400-400 0.0070 1000 2.8 4U, 25.5"D
PLA5K-600-240 0.0130 2500 7.8 4U, 25.5"D
PLA5K-800-100 0.0045 8000 3.6 4U, 25.5"D
PLA5K-1000-50 0.0060 20000 6 4U, 25.5"D
PLA6K-60-1500 0.0100 40 0.6 6U, 25.5"D
PLA6K-120-1500 0.0150 80 1.8 6U, 25.5"D
PLA6K-400-500 0.0075 800 3 6U, 25.5"D
PLA6K-600-300 0.0140 2000 8.4 6U, 25.5"D
PLA7.5K-60-1500 0.0100 40 0.6 6U, 25.5"D
PLA7.5K-120-1500 0.0150 80 1.8 6U, 25.5"D
PLA7.5K-400-600 0.0068 666.7 2.7 6U, 25.5"D
PLA7.5K-600-400 0.0140 1500 8.4 6U, 25.5"D
PLA7.5K-800-150 0.0045 5333.3 3.6 6U, 25.5"D
PLA7.5K-1000-75 0.0060 13333.3 6 6U, 25.5"D
Constant Resistance Mode
Transient Time Range :

CRM / CRH
Same As CC Mode
Transient Time Range : CRL Same As CV Mode
Temperature Coefficient : 

CRM / H
300 ppm / °C of Minimum Resistance
Temperature Coefficient : CRL 300 ppm / °C of Maximum Resistance
Constant Resistance Mode - Program : CR Resolution*2 - 1/16000 Of Rated Value
*1 All Mode Specification measure by 25˚C room temperature unless otherwise specified

*2 Transient Mode Specification must be x2
Common
Constant Voltage Mode (0-V) V
CVMedium Range 0 - ( V / 2) V
CVLow Range 0 - ( / 10) V
Temp Coefficient 100 ppm / °C of Rated Voltage
Transient Time Range
Fast Band(default, Osc1) 0.500 ~ 51.19 ms
Slow Band(Osc2, Osc3) 0.500 ~ 511.9 ms
CV Resolutions*2 1/16000 of rated voltage
CV Accuracy*2 (CVH, CVM, CVL) 0.05% +/- (0.1% x Vmax) V
Display Specifications
CV Resolution 1/16000 of Rated Voltage
CV Accuracy (CVH, CVM, CCL) 0.05% +/- (0.1% x V) V
Constant Power Mode
CPHigh Range (0-P) W
CPMedium Range 0 - (P/2) W @ DC input current ≤ (I/2) A
CPLow Range 0 - (P/10) W @ DC input current ≤ (I/10) A
Transient Time Range Same as CC Mode
Temperature Coefficient 300 ppm / °C of Rated Power
Constant Power Mode : Program
CPHigh Accuracy*2 1.00% +/- (Px0.5%) W @ input current > (I/20) A, input voltage > (V/10) V
CPMedium Range 1.00% +/- (Px0.5%) W @ input current > (I/100) A, input voltage > (V/10) V
CPLow Range 1.00% +/- (Px0.5%) W @ input current > (I/1000) A, input voltage > (V/5) V
Program CP Resolution*2 1/16000 of Rated Power
Constant Current Mode
CCHigh Range 0 - I A
CCMedium Range 0 - (I/2) A
CCLow Range 0 - (I/10) A
Transient Time Range
Fast Band (default, Osc1) 0.050 ~ 51.19 ms
Slow Band (Osc2, Osc3) 0.500 ~ 511.9 ms
Temperature Coefficient 100 ppm / °C of Rated Current
Constant Current Mode : Program
CC Resolution*2 1/16000 of rated current
CCHigh Accuracy*2 LHM 0.05% +/- (Ix0.1%) A
Constant Resistance Mode
Transient Time Range : CRM / CRH Same As CC Mode
Transient Time Range : CRL Same As CV Mode
Temperature Coefficient : CRM / H 300 ppm / °C of Minimum Resistance
Temperature Coefficient : CRL 300 ppm / °C of Maximum Resistance
Constant Resistance Mode - Program
CR Resolution*2 1/16000 of rated value
External Programming Mode
Monitor Output Signal 0-10 Volts output for 0 to full scale value
VMON Accuracy 0.10% +/- (Vx0.1%) V
IMON Accuracy 0.10% +/- (Ix0.1%) A
Analog Program 0~10 Volts Input yields 0 -- selected full scale loading in all modes
Accuracy Same As Internal ± 0.1% Rating
Input Impedance 200 k Ω ± 1 %
BandWidth(-3dB) Limited By Internal Transient Time
Remote Interface GPIB / RS-232 / ETHERNET / USB
Programmable Protection
Power (OPP)
Range (Px1.05/800) ~ (Px1.05) W
Resolution (Px1.05/8000) W
Accuracy 0.50% +/- (P x 21 / 8000) W
Voltage (OVP)
Range (Vx1.05/1600) ~ (Vx1.05) V
Resolution (Vx1.05/16000) V
Accuracy 0.20% +/- (Vx1.05/800) V
Current (OCP)
Range Ix1.05/1600) ~ (Ix1.05) A
Resolution (Ix1.05/16000) A
Accuracy 0.20% +/- (Ix1.05/800) A
Under Voltage Lockout (UVL)
Mode Input On / Continuous
Range ((V/4000*3) ~ Vmax) V
Resolution (V/4000) V
Accuracy 2.50% +/- (V/800) V
Anti-Oscillation Default/ Osc1/ Osc2/ Osc3/ Disable
Protection
Over Power (OP) (Px1.05) +/- (Px0.02) W
Over Voltage (OV) (Vx1.05) +/- (Vx0.02) V
Over Current (OC) (Ix1.1) +/- (Ix1.1x0.01/1.05) A
Over Temp (OTP) 90.00 +/- 5.000 °C
Reverse Max Current (RCP) (Ix1.1) A
Short Max Current (Ix1.02) A
Remote Inhibit (RI) Short
Fault Indicator SPDT Relay (30Vdc/0.5A or 125Vac/0.25A
General
AC Input 95~240 Vac 48~62 Hz
Derating for higher temperatures (-)1.67% Rated Power / °C
Operating Temperature 5 °C ~ 40 °C
Transient Mode
Frequency Range 0.100 - 10,000 Hz
Duty Range 1.000 - 100.0%
Transient Time Accuracy 10.0% +/- 50% of Min Time
Dielectric Strength
Primary Circuit To Chassis 1500 Vac for 1 min
Primary Circuit To Load Terminal 1500 Vac for 1 min
Load Terminal To Chassis 1500 Vdc for 1 min

More Product Information

AMETEK Programmable Power

Located in San Diego, California, AMETEK Programmable Power designs, manufactures, and markets precision, AC and DC programmable power supplies, electronic loads, application specific power subsystems, and compliance test solutions for customers requiring and valuing differentiated power products and services. Also part of our business is VTI Instruments, which delivers precision modular instrumentation and systems for electronic signal distribution, acquisition, and monitoring, used in the world's most demanding test applications. 

AMETEK Programmable Power boasts one of the industries' broadest portfolios of programmable power products under the well-known and respected Sorensen, Elgar, and California Instruments brands. AMETEK Programmable Power’s products serve a wide range of stimulus (T&M) and process power needs in applications including semiconductor fabrication, commercial and defense ATE, oil exploration, solar array and battery string simulation, avionics, general R&D and EMC compliance testing. 

VTI Instruments provides products and systems which are used to monitor and record data that characterizes the physical integrity and performance of aircraft, engines, and other large structures, as well as automate the functional testing of complex electronic systems. VTI Instruments is recognized as an industry leader with a reputation of providing reliable data, first time, every time. 

With strong brands, a broad product portfolio, exceptional precision power conversion and control expertise, proven power system integration capabilities and deep applications knowledge, AMETEK Programmable Power is your source for programmable power supplies, precision data acquisition instruments, and more.


Contact Details 

AMETEK Programmable Power, Inc. − San Diego 

9250 Brown Deer Road, San Diego, CA 92121, USA

Phone: 858-450-0085 

Fax: 858-458-0267 

Email: sales.ppd@ametek.com for general inquiries

Contact form

Test & Measurement

Download Line Card
AMREL - PLA Series Air-Cooled Programmable DC Electronic Loads
AMREL - PLA Series Air-Cooled Programmable DC Electronic Loads
AMREL - PLA Series Air-Cooled Programmable DC Electronic Loads
AMREL - PLA Series Air-Cooled Programmable DC Electronic Loads