IntelliPower - FA00136 Rugged UPS
-
400 VA, 250 Watt 120V AC Input & Output, Rugged, Rack Mount, Double Conversion, High Temperature On-Line UPS & Isolated Power Conditioning System with Frequency Conversion, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 2U 13 inch deep enclosure
TYPE | SPECIFICATION |
---|---|
Power Rating | 250W |
Chassis Configuration | 2U, ≤23"D |
Input Voltage | 120 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 120 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
1800VA, 1250W, 115VAC, 60Hz Isolated Input, 115Vac 60Hz Output, Freq. Changer, 8BHS (5Ah), 2U24.4, Flying Lead, SNMP, L5-30R Corded UPS
-
5000VA, 4000W, 120VAC 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, Extreme High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
3000 VA, 2100 Watts, 85 thru 265 VAC, 40 to 400 Hz Input and 120 VAC, 60 Hz Output, Double Conversion, On-Line, Isolated, Rugged Power Conditioner with Power Factor Correction for Military Applications
-
6000VA, 4500W, 115Vac 60Hz Isolated Input X2, 115Vac and 24Vdc Output, Freq Changer, EBP (96V) PB, 3U24, Aluminum, 2X Cir Mil, SNMP, Elcon 4-21-4, 4X Cir Mil UPS
-
External battery module with minimum battery run time of 30 minutes @ 960W
-
2000VA, 1400W, 120VAC or 230VAC at 50Hz or 60Hz Input with 120VAC, 60Hz Output, Double Conversion, Rugged, High Temperature, Isolated On-Line UPS with Power Factor Correction and Hot Swap Batteries for Military Applications
Secure, compact, scalable fixed, front-removable, or rear-removable blade servers made right here in the USA that maximize performance and adaptability for evolving applications
- Size - Up to four server blades within a single rugged enclosure help efficiently utilize rack space.
- Weight - Compact system design reduces overall weight of rack server infrastructure.
- Power - Shared resources optimize hardware usage and limit power requirements.
- Cost - Modularity and increased footprint lower hardware and maintenance costs.
-
Dual Input, Pole Mount Double Conversion Isolated On Line 120 and 277 VAC Input, 12, 24 and 48 VDC and 120 VAC pass through Output UPS System with Power Factor Correction in a NEMA 3R cabinet for Industrial applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form