IntelliPower - FA00281 Rugged UPS
-
Rugged, Double Conversion, High Temperature, Isolated, Auto Select 120/240VAC Global Input & 240VAC Output Online UPS System with Power Factor Correction for Industrial Applications
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 3U, ≥24"D |
Input Voltage | 208 VAC |
Input Frequency | 400 |
Input Connector | NEMA Type |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | IEC320 |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
625VA, 500W, 110/220VAC, 50/60Hz input and 110VAC 60Hz Output UPS w/power factor correction (PFC)
-
External Battery Pack with 2 strings of 4 each 12V9.6Ah Lithium Iron Phosphate Batteries
-
Dual Input, Pole Mount Double Conversion Isolated On Line 120 and 277 VAC Input, 12, 24 and 48 VDC and 120 VAC pass through Output UPS System with Power Factor Correction in a NEMA 3R cabinet for Industrial applications
-
1500VA, 1000W, Dual Primary and Backup 115VAC, 50/60Hz Input and 115VAC 50/60Hz Output, Double Conversion Rugged On-Line UPS with Power Factor Correction for Military Applications
-
1500VA, 1050W, 120VAC at 60Hz Input and 120VAC at 60Hz Output, Double Conversion, Rugged, High Temperature, Online UPS with Power Factor Correction for Industrial Applications
-
1200 VA, 1000 Watts, 85 thru 265 VAC, 50 or 60 Hz Input and 120 VAC, 60 Hz Output, Double Conversion, On-Line, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
Power rating of 1800 watts minimum, Global Input Voltage, Output Voltage at 120VAC at 60Hz 1.5Hz
-
2200 VA, 2120 W UPS with 120 VAC Input, 120 VAC and 28 VDC Outputs, Frequency Changer, Isolated, Power Factor Corrected, Hot Swap Tower, 17”H x 7.75”W x 22”D, Rugged, Double Conversion, to Provide Power Conditioning for Navy Applications
-
Global Input, Rugged, Rack Mount, Double Conversion On Line UPS & Isolated Power Conditioning System with Frequency Conversion, Auto-select Input Voltage Select, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 1U Enclosure
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form