IntelliPower - FA10600 Rugged UPS
-
7500VA, 5500W, 220VAC 1Ph 45-440Hz Isolated Input, 220VAC 60Hz Output, Freq Changer, 24BHS EBM, 3U25, Terminal Block AC Input Panel Mount, Terminal Block AC Ouput Panel Mount, SNMP, 2 x 2 Anderson EBP, Neutral Bonded, Double Conversion, Rugged, High Temperature, On-line UPS with Input Power Factor Correction
TYPE | SPECIFICATION |
---|---|
Power Rating | 150W |
Chassis Configuration | 3U, ≥24"D |
Input Voltage | 120 VAC |
Input Frequency | 400 |
Input Connector | Terminal Block |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | IEC320 |
Battery Runtime | ≥ 20 minutes |
Battery Chemistry | Lithium Iron Phosphate |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
Ruggedized sensor package, qualified to same rigorous standards applied to electronic gages
-
Integrated temperature compensation FBG sensor
-
Connector protection fittings available for harsh environments
-
Double-ended design supports multiplexing of many sensors on one fiber
-
Two standard gage lengths of 25 and 100 cm
-
P67 rated for protection from dust and water ingress
-
5000VA, 4000W, 115VAC 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Shipboard Applications
-
Rugged Rack Mount Double Conversion On Line Isolated Power Conditioning System with Power Factor Correction (No batteries)
-
Dual Input, Pole Mount Double Conversion Isolated On Line 120 and 277 VAC Input, 12, 24 and 48 VDC and 120 VAC pass through Output UPS System with Power Factor Correction in a NEMA 3R cabinet for Industrial applications
-
16 each 12V14Ah Pb-Acid batteries fixed within a 3U aluminum chassis
-
3000 VA, 2700 W, 115 VAC at 60 Hz input and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS and EBP, with power factor correction for Navy shipboard applications
-
High Temp Frequency Converter, Power Conditioner Rugged Rack Mount Double Conversion On Line with Isolation and Power Factor Correction
-
3000 VA, 2700 W, 220 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer and optional EBP, with power factor correction for Navy shipboard applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form