2 strings of 8 ea 12VHX50 lead acid batteries and two hot swap drawers
TYPE | SPECIFICATION |
---|---|
Chassis Configuration | 3U, ≥24"D |
Output Connector | Pigtail |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
More Product Information
-
IRIG’s A and B and NASA 36 time code inputs
-
+3.3V or +5V signaling
-
1PPS Sync input
-
External Event (Time Tag) input
-
Three programmable pulse rate outputs
-
Match Time output
-
Industrial Temperature Range option
-
Optional on-board GPS option
-
Optional HaveQuick input/output
-
Optional IRIG B time code output
-
3000 VA, 2500 W, 180-260 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer, with power factor correction
-
1400VA, 900W, Isolated 120VAC Single Phase 60Hz Input and 120VAC, 60Hz Output, Double Conversion Input On Line UPS and Power Conditioning System with Lithium Iron Phosphate Batteries and Power Factor Correction for Commercial Applications
-
3100 VA, 3100 W, 2 ea. 115 VAC at 60 Hz input with automatic transfer failover and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with optional EBP and power factor correction for Navy shipboard applications
-
External Battery Charger
-
2 Stage
-
2 Strings of 7-Battery-84V Nominal Modular Enclosure to be used for recharging external battery packs as a storage and maintenance function
-
5KVA, 4KW, Double Conversion, On Line, Isolated 115VAC, 60Hz 3-Phase Delta Input UPS with 120VAC, 60Hz Single Phase Output and Power Factor Correction for Shipboard Applications
-
5000VA, 4200W, 115/230VAC 50/60Hz Input and 230VAC 60Hz Output UPS
-
Rugged, Double Conversion, Global Input, Isolated, Online UPS System with Power Factor Conversion and Frequency Conversion for Land Based Military Applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.