IntelliPower - FA00350-20 Rugged UPS
-
3000 VA, 2500 W, 180-260 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer, with power factor correction
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 2U, ≥24"D |
Input Voltage | 120 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | < 20 minutes |
Battery Chemistry | Lithium Iron Phosphate |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
7500VA, 5500W, 220VAC 1Ph 45-440Hz Isolated Input, 220VAC 60Hz Output, Freq Changer, 24BHS EBM, 3U25, Terminal Block AC Input Panel Mount, Terminal Block AC Ouput Panel Mount, SNMP, 2 x 2 Anderson EBP, Neutral Bonded, Double Conversion, Rugged, High Temperature, On-line UPS with Input Power Factor Correction
-
External Battery Pack w/ 2 strings of 9 LiFe Batteries (14 Total) in 3U24” D Enclosure
-
3000VA, 2400W, 120/208VAC, 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
Three-phase, 440 VAC at 60 Hz Input, Isolated, Double Conversion Rugged Frequency Converter with 2000 Watts at 24 VDC output to provide Power Conversion and Power Conditioning
-
2000VA, 1600W output, double conversion, rugged, high temperature, global input, isolated, on line UPS providing auto-select for inputs of either 120 or 240VAC with output of 120VAC, 60 Hz to provide power back up, power conversion and power conditioning with hot swap battery, frequency conversion and power factor correction
-
1000 VA, 750 W, 115 VAC Input, Double Conversion, Rugged, Isolated, High Temperature, Wall Mount On-Line UPS with 115 VAC at 60 Hz Output and Two Hot Swap Battery Drawers to provide Power Backup and Power Conditioning for Military Applications
-
2250KVA, 1.9KW Double Conversion, On-Line, Isolated 440V 3-Ph, 60Hz Input UPS with 440V 3-Ph, 60Hz Output UPS
-
Global Input, Double Conversion, Rugged, High Temperature, Isolated, Online UPS System with Hot Swap Battery, Power Factor Correction and MIL STDs for Navy Shipboard Applications
-
500VA, 350W, Global 110/220 VAC Input, Double Conversion, Rugged, Isolated, Rack Mount On Line UPS with 220VAC at 60Hz Output to provide Power Backup and Power Conditioning for Military Applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form