IntelliPower - FA00340 External Battery Charger
-
96 Volt, 2 Amp Battery Drawer Charger
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 2U, ≤23"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 120 VAC |
Output Connector | Pigtail |
Communication | None |
More Product Information
-
3000 VA, 3000 Watts, input AC 120 or 240 VAC (-10%+15%), input frequency 40 to 70 Hz, Input and Output AC, 120 or 240 VAC (-10% + 15%); 120 VAC (+/-3%) output frequency 60 Hz, (+/-3 Hz), Double Conversion, On-Line, Isolated, Rugged UPS with Power Factor Correction for military Applications
-
IntelliPower Breaker Distribution Panel with a 100 amp rating, for power distribution from customer generator to UPS Inputs
-
Manufactured for Military, Industrial and Commercial applications
-
6000 VA, 4500 W, 440 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS. Power factor correction for Navy shipboard applications
-
230Vac Input, IEC 60320-C13 suitable for 115/230Vac, IEC 60320-C14 x 8 Suitable for 115/230Vac, Each Output having a Circuit/Switch control, 1U9.5, Aluminum
-
AC input with internal batteries, extreme high temperature, rugged, double conversion UPS with 72VDC in and 120VAC out at 60 Hz for industrial applications in a 2U enclosure
-
1500 VA, 1350 W, 115 VAC at 60 Hz input and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer and power factor correction for Navy shipboard applications
-
Rugged Rack Mount Double Conversion On Line Isolated Power Conditioning System with Power Factor Correction (No batteries)
-
7500VA, 5500W, 220VAC 1Ph 45-440Hz Isolated Input, 220VAC 60Hz Output, Freq Changer, 24BHS EBM, 3U25, Terminal Block AC Input Panel Mount, Terminal Block AC Ouput Panel Mount, SNMP, 2 x 2 Anderson EBP, Neutral Bonded, Double Conversion, Rugged, High Temperature, On-line UPS with Input Power Factor Correction
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.