Our Partners

Displaying 1 total

Power Supply Test Systems, AC/DC Electronic Loads and Sources


Measure, graph and record three sensor types with one tool
The 1524 Reference Thermometer measures, graphs, and records PRTs, thermocouples, and thermistors. This thermometer readout delivers exceptional accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere.
The 1524 lets you handle field applications, laboratory measurements, and data logging with ease. And with the dual channel measurement capabilities of the model 1524, you can do twice the work in half the time.
Three sensor types

  • PRTs: –200 °C to 1000 °C
  • Thermocouples –200 °C to 2315 °C
  • Precision thermistors: –50 °C to 150 °C

Accuracy

  • PRTs: up to ±0.011 °C
  • Thermocouples: ±0.24 °C for J,K,L,M
  • Precision thermistors: ±0.002 °C

Fast mode

  • PRTs: 0.45 seconds per sample
  • Thermocouples: 0.3 seconds per sample
  • Precision thermistors: 0.3 seconds per sample

Graphical display

  • 128x64 backlit LCD graphic display
  • Plot and scale trends in real time
  • Simultaneous dual channel readings


  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.


  • A top performing True-RMS current clamp for AC-only current measurements to 600 A
  • Measures AC and DC voltage to 600 V
  • Measures resistance to 6000 Ω with continuity detection
  • Offers state of the art signal processing to provide stable readings even in noisy electrical environments


The 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).

  • Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
  • Ideal for gas flow calibration (custody transfer) applications
  • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
  • Pt100 RTD input for temperature measurement, (probe optional)
  • Switch test on both pressure inputs
  • Pressure displayed in the user’s choice of 19 engineering units
  • Large backlit graphic display can display up to three inputs simultaneously
  • Store five instrument setups for recall and use


  • Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
  • Delivers very high accuracy—0.01%—and 1 mA resolution
  • Measures voltage output process signals from PLCs and transmitters
  • Sources or simulates 24 mA loop current
  • Sources voltage to 100 mV or 10V
  • Provides typical 18 hour battery life