IntelliPower - FA00017 Frequency Converter

DC to AC Converter with Output Isolation  

IntelliPower - FA00033 Frequency Converter

3000 VA, 240-240 Volt Transformer, surge protection  

IntelliPower - FA00034 Frequency Converter

3000VA, 2100W, 90 to 265VAC 45 to 400Hz Input and 120VAC 60Hz Output with ECS case  

IntelliPower - FA00061 Frequency Converter

Rugged High Temperature Double Conversion On-Line Isolated Voltage and Frequency Converter & Power Conditioning System with Power Factor Correction for Military Applications (No...

IntelliPower - FA00084 Frequency Converter

3000VA, 240VAC 50/60Hz Isolated Input, 120VAC 50/60Hz Output, 3U17, Steel, IEC6020-C20 Corded, L5-30R Corded  

IntelliPower - FA00111 Frequency Converter

High Temp Frequency Converter, Power Conditioner Rugged Rack Mount Double Conversion On Line with Isolation and Power Factor Correction  

IntelliPower - FA00149 Frequency Converter

IntelliPower Rack Mount Input Isolation Transformer for 120VAC Input and Output. Includes surge protection  

IntelliPower - FA00206 Frequency Converter

Global Input Rugged Rack Mount Double Conversion On Line Isolated Power Conditioning System with Power Factor Correction  

IntelliPower - FA00215-03 Frequency Converter

3000VA, 2500W, 115Vac 400Hz 3 Phase, 12 Pulse Isolated Input, 28Vdc Output, Freq Changer, No Battery, 3U23.98, Aluminum, Cir Mil, RS232, Cir Mil  

IntelliPower - FA00219 Frequency Converter

3000VA, 2400W, 270VDC Input and 115VAC, 60Hz Output, Isolated Rugged Extreme High Temperature Rack Mounted Power Converter in an aluminum enclosure  

IntelliPower - FA00221 Frequency Converter

3000 VA, 120-120 Volt Transformer, surge protection  

IntelliPower - FA00289 Frequency Converter

Power Conditioner 3000VA, 3000W, Isolated, 220VAC at 50 Hz Input, and 220VAC at 60Hz Output  

IntelliPower - FA00312 Frequency Converter

6000 VA, 6000 W, 74 VDC Input and 2 isolated independent 120 VAC at 60Hz Outputs, Rugged Extreme Temperature Inverter  

IntelliPower - FA00325 Frequency Converter

2000VA, 1500W, 120/240VAC 50/60Hz Input and 120VAC 60Hz Output Converter  

IntelliPower - FA00389 Frequency Converter

1500VA, 1400W High Temperature Double Conversion On Line IPS with 120VAC, 60Hz Input, 120VAC and Thee DC Outputs, Input Power Factor Correction for Highly Rugged Military...

IntelliPower - FA10098 Frequency Converter

Power Conditioner 3000VA, 3000W, Isolated, 120VAC at 50/60 Hz Input, and 220VAC at 50Hz Output  

IntelliPower - FA10208 Frequency Converter

1100Va, 1000W, 120Vac 60Hz Input, 120Vac 60Hz 600Va 500W Non-Isolated Output, 28Vdc 500W Isolated Output, Freq Changer, No Battery, 1U24, Aluminum, IEC-C14, SNMP, 3 x NEMA...

Installs and grounds in less than 5 minutes
Save time with quick and easy installation with the CV Series – 5 minutes or less.
  • One technician
  • One hole with standard Greenlee® punch
  • Panel door does not need to be removed
  • Grounds instantly to metal enclosure with patent-pending AutoGround™ process
  • Maintains panel arc test ratings up to 63kA when properly installed
Work more efficiently with Fluke ClirVu® CV201 50 mm (2 in) Infrared Windows
  • NFPA 70E processes significantly reduced due to less work permit requirements
  • Faster and more comfortable inspections because full PPE is often not required
  • Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
  • CV201 is Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
  • Convenience of both quick turn or security keyed access


  • True-RMS digital multimeter with the features professional technicians prefer
  • Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
  • Measures AC and DC voltage to 1000 V
  • Delivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
  • Safety rated CAT III 1000 V, CAT IV 600 V


  • 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃
  • Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
  • Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.


Solve power problems you meet in your daily work, now that electrical loads in industrial and commercial buildings are often too complex to be calculated by the classical model of power.
Understand the major elements that affect power quality with our online webcast and supporting guidebook:
  • particularly inductive loads
  • harmonic distortion
  • three-phase power unbalance


  • MATLAB® and LabVIEW® software compatibility allows users to integrate infrared data, images and videos to support R&D analysis
  • 320 x 240 resolution
  • See the details you need with optional smart lenses: 2x and 4x telephoto, wide angle and macro lenses
  • Optimize images, generate customizable reports and export images to the format of your choice with SmartView® desktop software
  • Wirelessly connect your camera to the Fluke Connect® system to easily share and edit images