IntelliPower - Frequency Converters
See "Specifications & Details" tab for more information
|
Frequency Converters FA00061 |
|
|---|---|
|
Rugged, High Temperature, Double Conversion, On-Line, Isolated Voltage and Frequency Converter & Power Conditioning System with Power Factor Correction for Military Applications (No batteries). |
|
|
Power Rating |
1400-2099 Watts |
|
Chassis Configuration |
3U Rackmount |
|
Input Voltage |
120 VAC |
|
Output Voltage |
115 VAC |
|
Input Connector |
Pigtail |
|
Output Connector |
NEMA |
|
Communication |
RS232 |
|
Frequency Converters FA10099 |
|
|---|---|
|
Global Input, Rugged, Rack Mount Double Conversion On-Line Isolated Frequency Converter System with Power Factor Correction. |
|
|
Power Rating |
2100-2099 Watts |
|
Chassis Configuration |
2U Rackmount |
|
Input Voltage |
85 to 265 VAC |
|
Output Voltage |
120 VAC |
|
Input Connector |
IEC |
|
Output Connector |
IEC |
|
Communication |
RS232 |
More Product Information
HYPERLABS offers ultra-broadband inverters with a typical fixed insertion loss of 2 dB and a very flat frequency response from 150 kHz to 100 GHz.
- First commercial high-performance cesium atomic clock using optical pumping — 100 times more atoms can be measured compared to magnetic clocks.
- Offers 10 times higher clock stability.
- Double the operational lifetime compared with traditional magnetic cesium clocks.
- Wide range of ultra-low noise frequency outputs (e.g. 5 MHz, 10 MHz, 100 MHz) — plus multiple 1PPS outputs, supporting high-precision timing distribution.
- Frequency accuracy ≤ ±5 × 10⁻¹³; reproducibility after power cycle ≤ ±1 × 10⁻¹³.
- Adjustable frequency offset: resolution ±1 × 10⁻¹⁵, range ±1 × 10⁻⁹.
- Rack-mount (3RU, 19″)
See "Specifications & Details" tab for more information
The TEM horn antenna is an antenna used for conducting close proximity radiation immunity evaluation test (near electromagnetic field immunity test) of electromagnetic waves radiated from various wireless transmitters such as mobile devices.
In the future, close proximity radiation immunity evaluation test using the TEM horn antenna is expected to expand to various product standards such as medical equipment (IEC 60601-1-2) and multimedia equipment (CISPR 35).NoiseKen's TEM horn antenna has a wide band, low VSWR, and wide electric field uniformity offering an ideal solution for an efficient close proximity radiation immunity test.
- A TEM horn antenna compliant with IEC 61000-4-39 Ed.1.
- Test without changing the antenna in the frequency range of 380MHz to 6GHz.
- Low VSWR and high GAIN enable efficient electromagnetic wave radiation.
- Wide field uniformity reduces the number of times of movement of the antenna when radiating the EUT.
- Since the maximum point of the near electric field distribution for each frequency is at the center, enables radiation on the EUT based on the axis of the antenna. Hence, significantly simplifies test point alignment.
The HL945x family of transition time converters (also known as low-pass absorptive rise time filters) provide superior return loss and flat group delay.
- Complete bias circuits
- Requires no external components
- Extremely flat output power versus frequency characteristics
The NC500 (through-hole) and NC500SM (surface mount) Series noise modules are an economical solution for built-in test requirements. They contain complete bias circuits and require no external components. Some models contain additional gain stages for high power ENR output (51 dB). The surface mount package is suitable for mounting on micro strip. The modules have extremely flat output power versus frequency characteristics that are insensitive to temperature and voltage variations.
- Dual-channel and differential voltage measurements
- 1% accuracy at full scale
- True RMS response below 30 mV
- Optional low-frequency probe for measurements from 10 Hz to 100 MHz
- DC recorder output
- IEEE-488 interface standard, RS-232
The 9240 series is the latest addition to the popular 9200 series of RF voltmeters. It combines accuracy, smart probes, and operator features that have never before been available in its price range. It is simple to use on the bench, and comprehensive enough to integrate into an ATE system. Boonton’s proven voltage probes directly measure from 200 μV to 10 V with usable indication as low as 50 μV and have true RMS response below 30 mV.
- Complete bias circuits
- Requires no external components
- Optimizations available for frequency range and output levels
The NC520 low voltage (surface mount) noise module is an economic solution for built-in test requirements. It contains complete bias circuits and require no external components.
The surface mount package is suitable for mounting on microstrip. The modules produce extremely flat output power versus frequency characteristic that is insensitive to temperature and voltage variations.
Typical applications for the NC520 module includes built-in test equipment (bite), signal strength meters for cellular, pcs, catv, calibrators, spectrum analyzers, radar warning receivers (rwr), and dither A/D quantization error. Maury can optimize frequency range and output levels for specific applications.
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.