Digital & Vector Signal Analyzers, Signal Generators and Fast Synthesizers, Spectrum


  • Two electrically isolated inputs
  • CAT III 1000V / CAT IV 600V safety rated
  • 200 MHz bandwidth model
  • 2.5 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • Up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock


  • Two electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • 100 MHz bandwidth model
  • 1.25 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • Up to 7 hour (BP291 included standard)
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock


  • Rugged, professional grade laser distance meter featuring advanced laser distance measurement technology
  • Instantly measures up to 50 m (165 ft.) with one-button point-and-click operation
  • Offers Pythagoras calculation to indirectly measure height from two other measurements
  • Quickly calculates area (square feet/meters) and volume
  • Offers easy to-use addition and subtraction function


  • Two electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • 500 MHz bandwidth model
  • 5 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • Up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock


Measure, graph and record three sensor types with one tool
The 1524 Reference Thermometer measures, graphs, and records PRTs, thermocouples, and thermistors. This thermometer readout delivers exceptional accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere.
The 1524 lets you handle field applications, laboratory measurements, and data logging with ease. And with the dual channel measurement capabilities of the model 1524, you can do twice the work in half the time.
Three sensor types

  • PRTs: –200 °C to 1000 °C
  • Thermocouples –200 °C to 2315 °C
  • Precision thermistors: –50 °C to 150 °C

Accuracy

  • PRTs: up to ±0.011 °C
  • Thermocouples: ±0.24 °C for J,K,L,M
  • Precision thermistors: ±0.002 °C

Fast mode

  • PRTs: 0.45 seconds per sample
  • Thermocouples: 0.3 seconds per sample
  • Precision thermistors: 0.3 seconds per sample

Graphical display

  • 128x64 backlit LCD graphic display
  • Plot and scale trends in real time
  • Simultaneous dual channel readings