Product Finder

Displaying 1 - 15 of 15
Product Results:
Amplifier Research - 125A250 - 125 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 125A250 - 125 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

125 Watts CW 10kHz–250MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 150A100D - 150 Watt CW, 10 kHz - 100 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 150A100D - 150 Watt CW, 10 kHz - 100 MHz solid-state, self-contained, air-cooled, broadband amplifier

150 Watts CW 10kHz–100MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 150W1000B - 150 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 150W1000B - 150 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

150 watts CW 80MHz–1000MHz Class A Portable Full VSWR–tolerant CE & RoHS...
Amplifier Research - 175A400 - 175 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 175A400 - 175 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

175 Watts CW 10kHz–400MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 250A400 - 250 Watt CW, 10 kHz - 400 MHz

Amplifier Research - 250A400 - 250 Watt CW, 10 kHz - 400 MHz

250 Watts CW 10kHz–400MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 250U1000 - 250 Watt CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 250U1000 - 250 Watt CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

250 watts CW 100kHz–1000MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 250W1000C - 250 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 250W1000C - 250 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

250 watts CW 80MHz–1000MHz Class A Portable Full VSWR–tolerant CE & RoHS...
Amplifier Research - 350A400 - 350 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 350A400 - 350 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

350 Watts CW 10kHz–400MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 350AH1A - 350 Watt CW, 10 Hz - 1 MHz amplifier (w/ DCP, IEEE-488, RS-232, USB and Ethernet interfaces )

Amplifier Research - 350AH1A - 350 Watt CW, 10 Hz - 1 MHz amplifier (w/ DCP, IEEE-488, RS-232, USB and Ethernet interfaces )

M1 through M3 350 Watts CW 10Hz–1MHz  
Amplifier Research - 500A250D - 500 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 500A250D - 500 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

500 Watts CW 10kHz–250MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 500U1000 - 500 watts CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 500U1000 - 500 watts CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

500 watts CW 100kHz–1000MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 500W1000C - 500 Watt CW, 80 - 1000 MHz

Amplifier Research - 500W1000C - 500 Watt CW, 80 - 1000 MHz

500 watts CW 80MHz–1000MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 600A400 - 600 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 600A400 - 600 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

600 Watts CW 10kHz–400MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 750W1000B - 750 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 750W1000B - 750 Watt CW, 80 - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

750 watts CW 80MHz–1000MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 800A3B - 800 Watt CW, 10 kHz - 3 MHzself-contained, air-cooled, broadband, solid-state amplifier

Amplifier Research - 800A3B - 800 Watt CW, 10 kHz - 3 MHzself-contained, air-cooled, broadband, solid-state amplifier

M1 through M3 800 Watts CW 10kHz–3MHz  

Fluke CLKT Infrared Windows are Available in Three Sizes 50 mm (2 in), 75 mm (3 in) and 100 mm (4 in)

Each CLKT infrared window is engineered and tested to withstand electric-arcs up to 50 kA for 30 cycles.

The ClirVu® coating - exclusive to Fluke infrared windows - seals the optic prior to assembly to protect against moisture degradation making it perfect for very hot and very cold outdoor environments.

Each Fluke infrared window is delivered with an identification plate attached for unique, on-site numbering for rapid location confirmation and faster repairs.

CLKT infrared windows come complete with a security access key, installation instructions and self-adhesive drilling template.

For 5 minute or less installation and Autoground consider the CV300.


  • For electrical and electronic testing and troubleshooting in field service
  • Ideal where reliability and dependability are required
  • Min/Max/Average to record signal fluctuations
  • CAT III 600V


  • Detects and pinpoints the exact location of the SF6 leak – without shutting down equipment
  • Quick entry/exit button allowing quick toggling between gas imaging and infrared mode
  • 320 x 240 resolution for gas and infrared images; SuperResolution increases to 640 x 480, only in infrared mode
  • Get in-focus images in both infrared and gas modes with a touch of a button with LaserSharp® Auto Focus
  • Wirelessly connect your camera to the Fluke Connect® system to make faster decisions. Team members can see the same data and collaborate on identifying the problem or authorize work before you've left the inspection site.
  • No need for pencil and notebook:
    • IR PhotoNotes™ annotation system captures digital images of equipment details, e.g. serial numbers and surrounding area conditions
    • Record any additional notes with voice annotation and save them with the image
  • See additional details with optional smart lenses – no calibration required when swapping them between compatible cameras
  • Optimize images, perform analytics, generate quick, customizable reports and export images to the format of your choice with SmartView® desktop software, included with your purchase
  • Capture clear, accurate infrared images focused throughout the entire field of view with MultiSharp™ Focus
  • Small and lightweight, fits easily into your tool box


  • Two electrically isolated inputs
  • CAT III 1000V / CAT IV 600V safety rated
  • 200 MHz bandwidth model
  • 2.5 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • Up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock


Solve power problems you meet in your daily work, now that electrical loads in industrial and commercial buildings are often too complex to be calculated by the classical model of power.
Understand the major elements that affect power quality with our online webcast and supporting guidebook:
  • particularly inductive loads
  • harmonic distortion
  • three-phase power unbalance