Product Finder


  • Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
  • Expand lower range capability with additional 2700G Reference Gauges
  • Adaptors to provide hand tight connection to common NPT, BSP, and metric fitting types
  • Included reference gauges are battery operated and capable of using line power too
  • Portable with a sturdy carrying case
  • Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
  • Expand lower range capability with additional 2700G Reference Gauges
  • Adaptors to provide hand tight connection to common NPT, BSP, and metric fitting types
  • Included reference gauges are battery operated and capable of using line power too
  • Portable with a sturdy carrying case
P5510-2700G specific features:
  • Built-in pump for generating both vacuum and positive pressure
  • Pressure range 0 to 300 psi 2 MPa (300 psi)
  • Vacuum range 0 to 27 inHg (915 mbar)
  • Up to three 2700G Reference Pressure gauges
  • Fine needle vent valve for small adjustment and venting of pressure
  • No external bottle
  • Manually operated
P5513-2700G specific features
  • Pressure range 0 to 3000 psi (210 bar)
  • Vacuum range 0 to 24 inHg (800 mbar)
  • Up to three 2700G Reference Pressure gauges
  • Built-in screw press for fine pressure adjustments
  • Clean testing of process critical instrumentation
  • Requires pressure source (i.e. nitrogen bottle) for operation


The 1586A Super-DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, DC voltage, DC current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
  • Best-in-class temperature measurement accuracy
    • PRTs ±0.005 °C (using external DAQ-STAQ Multiplexer)
    • Thermocouples: ±0.5 °C (using High-Capacity Module and internal CJC)
    • Thermistors: ±0.002 °C
  • Input channels: Up to 40 isolated universal inputs
  • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
  • Selectable scan speed: Up to 10 channels per second
  • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
  • Real-time color trending: Chart up to four channels simultaneously
  • 6 1/2 digit display resolution for DC voltage, DC current, and resistance
  • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurment accuracy
  • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
  • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
  • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
  • Mx + B scaling and channel offset zero function
  • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded


  • Highly accurate non-contact infrared thermometer that instantly measures surface temperatures of food products
  • Allows taking rapid and frequent non-contact temperature measurements without risk of cross contamination
  • Measures temperatures from -35 to 275°C
  • Features HACCP check lights for instant recognition of safe/unsafe temperatures


  • Contact and non-contact thermometer in one
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F) accurate to +1.0°C or +1.0% of reading (whichever is greater)
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments.
  • Offers a distance-to-spot ratio of 50:1
  • Works with most K-type thermocouples


  • Power quality that meets the standard All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc.
  • Quick and reliable configuration A tablet computer provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
  • Threshold-free set up Apply thresholds after data is collected with Fluke Power Analyze Software – no need to worry about missed information due to incorrect setups
  • Captures everything Cross-channel and current triggering capture every measurement, on every channel, every time
  • Intuitive PC software Easily analyze data and generate reports with automated EN50160 reporting and compliance
  • Reporting has never been easier Auto Report creates either standard reports or customized reports with the minimum effort or hassle. Export reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.
  • Plug and play Set up in minutes with self-identifying current probes and single-lead voltage connections
  • No need to reconnect wires Swap channels internally with the wireless PDA or PC when connections are not correct
  • Measure every parameter Voltage and current on three phases, neutral, and ground
  • 5 MHz, 8000 Vpk waveform capture Get a detailed picture of even the shortest events
  • Quickly retrieve data With included SD memory card or via the 100 BaseT high-speed Ethernet connection. SD card includes automatic download to SD when no other connection is made to the instrument