Our Partners

Displaying 1 total

787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines.  3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors


  • Automatic pressure generation and regulation to 300 psi
  • Easily document the process using onboard test templates
  • Automatic internal fine-pressure adjustment
  • Measure, source and simulate 4 to 20 mA signals
  • 24V loop power for powering transmitters for tests
  • Bright dual/triple-channel color graphical display
  • HART communication for testing HART smart transmitters
  • Built-in leak testing for verifying test setups for leakage
  • Rugged portable design with standard 3-year warranty
  • Fluke Connect® App compatibility
  • Measure temperature with optional 720RTD probe
  • Measure Vdc for testing 1 V dc to 5 V dc output transmitters
  • Compatible with 700 Series and 750 Series pressure modules
  • Upload documented test results to DPCTrack2™ Calibration Management Software
  • Innovative semi-rigid carrying case designed for field work


Multifunction tester that tests to all local regulations
  • Includes "Insulation Pre-test" that detects when appliances are connected to the system and stops the test
  • Runs seven installation tests automatically in one sequence with a single connection through Auto Test
  • Allows you to share test results in real time over your smartphone via Fluke Connect Measurements


  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms


Ultra-cool dry-block calibrator with best-in-class stability
The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.


  • Contact and non-contact thermometer in one
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F) accurate to +1.0°C or +1.0% of reading (whichever is greater)
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments.
  • Offers a distance-to-spot ratio of 50:1
  • Works with most K-type thermocouples