Our Partners

Displaying 1 total

Video Compression, Time & Frequency Stds, GPS and Board Level Timing Solutions


  • A rugged, compact insulation resistance tester for residential and commercial electricians
  • Performs insulation tests from 0.01 MΩ to 2000 MΩ
  • Offers two insulation test voltages: 500 V and 1000 V
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Measures resistance from 0.01 Ω to 20.00 kΩ

  • Single-phase, plug-in voltage quality recorder for detecting and recording power quality problems
  • Records voltage trends, dropouts, and power quality to pinpoint the root cause
  • Plugs directly into the mains power socket to capture data
  • Presents a clear graphical summary of data and a quick overview of key power quality parameters


  • Accuracy: ≤1/8 in at 30 ft. (≤3 mm @ 10 m)
  • Red beam laser
  • Point Laser Direction: 90° up, down, left, right
  • Horizontal fan angle: 180 °
  • Vertical fan angle: 130°
  • Durable pendulum lock
  • IP54 rating to limit dust and water entry for years of operation on the job site.


Installs and grounds in less than 5 minutes
Save time with quick and easy installation with the CV Series – 5 minutes or less.
  • One technician
  • One hole with standard Greenlee® punch
  • Panel door does not need to be removed
  • Grounds instantly to metal enclosure with patent-pending AutoGround™ process
  • Maintains panel arc test ratings up to 63kA when properly installed
Work more efficiently with Fluke ClirVu® CV201 50 mm (2 in) Infrared Windows
  • NFPA 70E processes significantly reduced due to less work permit requirements
  • Faster and more comfortable inspections because full PPE is often not required
  • Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
  • CV201 is Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
  • Convenience of both quick turn or security keyed access


Discover sources of electrical energy waste, identify energy savings opportunities, and conduct load studies.
  • Key measurements: Automatically capture and log voltage, current, power, power factor, energy and associated values
  • Convenient instrument powering: You can power the instrument directly from the measured circuit instead of mains outlets
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream