Our Partners

Displaying 1 total

Front Ends, Modems, Payload Processors, Data Recorders, Launch Site & Satellite Test


  • Intrinsically safe infrared and contact thermometer
  • Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
  • Comes with a conductive case to safely carry the IR thermometer into hazardous areas
  • Offers a distance-to-spot ratio of 50:1


Accurate enough for lab use, and rugged and portable enough to take anywhere
  • Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Temperature range from –45 °C to 700 °C


  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC


  • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
  • GPS time synchronization: Correlate data with events or datasets from other instruments with precision
  • Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
  • Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
  • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
  • 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
  • Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
  • Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
  • Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions


  • Two electrically isolated inputs
  • CAT III 1000V / CAT IV 600V safety rated
  • 100 MHz bandwidth model
  • 1.25 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • Up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock