Installs and grounds in less than 5 minutes
Save time with quick and easy installation with the CV Series – 5 minutes or less.
One technician
One hole with standard Greenlee® punch
Panel door does not need to be removed
Grounds instantly to metal enclosure with patent-pending AutoGround™ process
Maintains panel arc test ratings up to 63kA when properly installed
Work more efficiently with Fluke ClirVu® CV201 50 mm (2 in) Infrared Windows
NFPA 70E processes significantly reduced due to less work permit requirements
Faster and more comfortable inspections because full PPE is often not required
Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
CV201 is Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
Convenience of both quick turn or security keyed access
Power quality that meets the standard All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc.
Quick and reliable configuration A tablet computer provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
Threshold-free set up Apply thresholds after data is collected with Fluke Power Analyze Software – no need to worry about missed information due to incorrect setups
Captures everything Cross-channel and current triggering capture every measurement, on every channel, every time
Intuitive PC software Easily analyze data and generate reports with automated EN50160 reporting and compliance
Reporting has never been easier Auto Report creates either standard reports or customized reports with the minimum effort or hassle. Export reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.
Plug and play Set up in minutes with self-identifying current probes and single-lead voltage connections
No need to reconnect wires Swap channels internally with the wireless PDA or PC when connections are not correct
Measure every parameter Voltage and current on three phases, neutral, and ground
5 MHz, 8000 Vpk waveform capture Get a detailed picture of even the shortest events
Quickly retrieve data With included SD memory card or via the 100 BaseT high-speed Ethernet connection. SD card includes automatic download to SD when no other connection is made to the instrument