Data Acquisition, Signal Conditioning, Switching, Modular Instruments & VXI Mainframes


  • Intrinsically safe infrared and contact thermometer
  • Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
  • Comes with a conductive case to safely carry the IR thermometer into hazardous areas
  • Offers a distance-to-spot ratio of 50:1


A solid, reliable, basic installation tester

  • Tests voltage and frequency
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)


  • Four electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • 100 MHz bandwidth model
  • 1.25 GS/s
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Quad meter measurements via scope BNC inputs
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan: up to 7 hours (BP291 included standard)
  • Charge spare battery using optional external battery charger (EBC290)
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock


Precision when you need it for infrared temperature calibration
  • Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
  • Large 57 mm (2.25 in) blackbody target
  • RTD reference well for contact temperature measurement
  • Small, compact design


Fluke 789 Temperature Kit features:

  • Unique new wireless measurement logging capability
  • Temperature measurement from -200 °C to 1372 °C using the t3000 FC
  • 24 V Loop power supply
  • HART mode setting with loop power (adds 250 ohm resistor)
  • 100% larger dual display
  • 1200 ohm drive capability on mA source
  • Enhanced backlight with two brightness settings
  • 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
  • Infrared I/O serial port compatible with
  • FlukeView® Forms Software Version 2.1
  • Externally accessible fuses for easy replacement

These 787 features are also included in the 789:

  • DMM designed to meet 1000 volt IEC 1010 CAT III standards
  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Simultaneous mA and% of scale readout
  • 20 mA DC current source/loop calibrator/ simulator
  • Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes