Dualos - NEO Check Valve Bodies
No Internal Valve
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
|
NEO 719F-P-06 |
4 |
0.4375-28 UNJEF Class 3A |
6 |
0.5625-24 UNJEF Class 3B |
1.50 |
0.81 |
|
NEO 720F-P-06 |
6 |
0.7500-16 UNJEF Class 3A |
6 |
0.5625-18 UNJF Class 3A |
1.80 |
1.00 |
| NEO 723F-P-08 |
10 |
0.7500-16 UNJEF Class 3A |
8 |
0.750-16 UNJF Class 3A |
2.03 |
1.13 |
|
NEO 724F-P-16 |
20 |
1.625-12 UNJ Class 3A |
16 |
1.3125-12 UNJ Class 3A |
3.32 |
1.88 |
| NEO 725F-P-08 |
10 |
0.8750-20 UNJEF Class 3A |
8 |
0.750-20 UNJEF Class 3A |
2.03 |
1.13 |
|
NEO 728F-P-06 |
8 |
0.7500-20 UNJEF Class 3A |
6 |
0.5625-24 UNJEF Class 3A |
6.70 |
1.38 |
|
NEO 729F-P-10 |
8 |
0.7500-20 UNJEF Class 3A |
10 |
0.8750-20 UNJEF Class 3A |
6.86 |
1.38 |
*Approximate Dimensions [inches]
Document
More Product Information
- 1-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz
- Guaranteed performance to 43.5 GHz with Extended-KTM ports
- PC control takes advantage of external computer processing power and functionality
- Small and lightweight package enables direct connection to the DUT
- No on-board data storage eliminates the need for data purging in secure applications
- All ShockLine VNAs share common software supporting GUI and program compatibility
- Time domain with time gating option enables easier and faster fault identification
- Simultaneous Sweep enabling users to operate multiple (up to four) MS46131A VNAs concurrently in independent software instances, unlocking true parallel measurement execution
-
On-Off power switch
-
15 A Circuit Breaker
-
Inlet - IEC C14 for use with any cordset
-
Outlets – (8) IEC C13
Test Tap:
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- Tri-Band S/X/KA: The best ratio of miniaturization/performance in any configuration
- AutoTrack S-Band: Supports any kind of operation
- Simultaneous Dual-Pol: For S, X and Ka-Band
- Earth Observation/Satellite Constellations: Meet your requirements
- Radome Covered: Maximum sustainability for any environment
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
- Modular design with multiple reference paths built in for high-availability.
- 6 expansion slots for customization and expansion.
- Industry-first GPS integrity checking with Timewallâ„¢
- Unique optical crosslink architecture for either Master-Slave hierarchical setups or Master-Master crosschecking and failover
- LCD display and keypad for basic status and configuration – secure web browser for detailed setup.
- Two 120/240 V Outlets
- Circuitry rated for 20 A
- 8’ Flexible Power Cord
- Shrouded Safety Banana Jacks
- Stable footprint with non-slip feet
Dualos
Website
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors