Teledyne LeCroy - MIPI DigRF v4 Decode Software

Teledyne LeCroy - MIPI DigRF v4 Decode Software
  • DigRF v4 Decodes
    • Low-speed (26 Mb/s)
    • Medium-speed (1248 Mb/s)
    • High-speed (1456 Mb/s)
  • DigRF v3 Decodes
    • Low-speed (6.5 Mb/s)
    • Medium-speed (26 Mb/s)
    • High-speed (312 Mb/s)
  • Convert DigRF 3G and v4 I and Q digital data to corresponding analog waveforms
  • Correlate analog waveforms with protocol decode on one screen
  • View decoded data in hexadecimal format
  • Decode information expands as the time base is adjusted or zoomed
  • Convenient table display with quick “Zoom to byte” capability
  • Quick search capability for specific message packets

More

MIPI DigRF decodes use color-coded overlays on various sections of the protocol for an easy-to-understand visual display. Depending on the time base or the amount of zoom, the decode information is condensed or expanded to better assist in understanding events during short or long acquisitions.

The Single Tool Enhances Productivity

The MIPI DigRF 3G decode solutions concentrates all your information in one place. Viewing the application layer of DigRF 3G and v4 signals on top of the physical layer provides a unique view that bus analyzers cannot. Measurements such IVRms, QVRms, PIQ, IDC, and QDC can be applied to the DigRF v4 signals for greater understanding.

Complete Compliance and Debug

For a complete MIPI toolset, Teledyne LeCroy offers a D-PHY compliance and decode package. QPHY-MIPI-DPHY provides automated compliance testing to the MIPI Alliance specification for D-PHY version 1.00.00. The D-PHY decode solution provides a simple and powerful debug solution for D-PHY, CSI-2 and DSI signals.

More Product Information

Teledyne LeCroy Education Discounts

Teledyne LeCroy offers a 15% discount on all Oscilloscopes, Probes and Options to education institutions

Teledyne LeCroy - WaveSurfer 510, 1 GHz Oscilloscope
  • 1GHz, 10 GS/s, up to 16 Mpts/ch
  • MAUI with OneTouch
    • Designed for Touch
    • Built for simplicity
    • Made to solve
  • WaveScan - Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode - Waveform Playback
  • Sequence Mode Segmented Memory
  • Power Analysis Software
  • Serial Trigger and Decode 
    • I2C SPI, UART
    • CAN, LIN, FlexRay, SENT
    • Ethernet 10/100BaseT, USB 1.0/1.1/2.0, USB2.0-HSIC
    • Audio (I2S, LJ, TDM)
    • MIPI D-PHY, DigRF 3G, DigRF v4
    • Manchester, NRZ

Teledyne LeCroy - Probe Adapters
  • Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope
  • Automatic probe detection
  • Provides all necessary power and offset control to the attached probe
  • Supports probes up to 4 GHz
  • Easy firmware updates
  • Wide variety of probes supported including:
    • Preamplifiers
    • Current Probes
    • Single-Ended Active Probes
    • Differential Active Probes

Teledyne LeCroy - PPE1.2KV 10:1/100:1 200/300 MHz 5M Ohm/50M Ohm Probes

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

All fixed-attenuation, standard probes automatically re-scale any LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.

Teledyne LeCroy - WaveMaster / SDA / DDA 8 Zi-B Oscilloscopes 4 GHz–30 GHz
  • Up to 30 GHz bandwidth and 80 GS/s sample rate
  • Most advanced oscilloscope user interface makes configuring complex measurements easy
  • The industry’s only true hardware 14.1 Gb/s serial pattern trigger
  • Add the Teledyne LeCroy HDA125 High-speed Digital Analyzer to create the most powerful, flexible mixed-signal test solution available
  • Low Jitter Measurement Floor and exceptional timebase stability
  • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
  • Integrated standard and custom measurements and math functions for unrivaled analysis capability
  • Multi-lane serial data eye, jitter and crosstalk analysis

Teledyne LeCroy - WaveSurfer 10, 1 GHz, 10 GS/s Oscilloscope
  • 1 GHz, 10 GS/s, up to 16 Mpts/ch
  • MAUI - Advanced User Interface
    • ​Designed for Touch
    • Built for Simplicity
    • Made to Solve
  • WaveScan- Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • 10.4" Touch Screen Display
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial trigger and Decode
  • Advanced Debug Toolkit adds: 
    • 10 GS/s on all 4 channels
    • 16 Mpts/ch memory (32 Intlv'd)
    • Sequence Mode Segmented Memory
    • History Mode Waveform Playback
    • 13 Additional Math Operators
    • 2 Math Functions

Teledyne LeCroy - Current Probes
  • ProBus active probe interface with automatic scaling in A/div
  • Autozero and degauss capabilities built into instrument's user interface
  • CP030
    • 30 Arms continuous current
    • 50 Apeak​ current 
    • 50 MHz bandwidth
  • CP030A
    • 30 Arms continuous current
    • 50 Apeak current
    • 50 MHz bandwidth
    • 1 mA/div sensitivity
  • CP031
    • 30 Arms continuous current
    • 50 Apeak current
    • 100 MHz bandwidth
  • CP031A
    • 30 Arms continuous current
    • 50 Apeak current
    • 100 MHz bandwidth
    • 1 mA/div sensitivity
  • CP150
    • 150 Arms continuous current
    • 500 Apeak current
    • 10 MHz bandwidth
  • CP500
    • 500 Arms continuous current
    • 700 Apeak current
    • 2 MHz bandwidth

Teledyne LeCroy - Differential Probes (<= 1.5 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point

Teledyne LeCroy - Optical Probes
Teledyne LeCroy's wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers.