Product Finder

Displaying 1 - 12 of 12
Product Results:
Amplifier Research - 100A400A - 100 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 100A400A - 100 Watt CW, 10 kHz - 400 MHz solid-state, self-contained, air-cooled, broadband amplifier

100 Watts CW 10kHz–400MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 100A400AM20 - 100 Watt CW, 4 kHz - 400 MHz - For BCI testing - solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 100A400AM20 - 100 Watt CW, 4 kHz - 400 MHz - For BCI testing - solid-state, self-contained, air-cooled, broadband amplifier

4kHz–400MHz Class A Portable Full VSWR– tolerant CE & RoHS compliant...
Amplifier Research - 100U1000 - 100 Watt CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 100U1000 - 100 Watt CW, 100 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

100 watts CW 100kHz–1000MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 10U1000 - 10 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 10U1000 - 10 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

10 Watts CW 10kHz-1000MHz Class A Portable Full VSWR– tolerant CE & RoHS...
Amplifier Research - 1U1000 - 1 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 1U1000 - 1 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

1 Watt CW 10kHz–1000MHz    
Amplifier Research - 2.5U1000 - 2.5 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 2.5U1000 - 2.5 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

2.5 Watts CW 10kHz–1000MHz  
Amplifier Research - 25A250B - 25 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 25A250B - 25 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

25 Watts CW 10kHz–250MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 25U1000 - 25 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 25U1000 - 25 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

25 Watts CW 10kHz-1000MHz Class A Portable Full VSWR– tolerant CE & RoHS...
Amplifier Research - 50A250 - 50 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 50A250 - 50 Watt CW, 10 kHz - 250 MHz solid-state, self-contained, air-cooled, broadband amplifier

50 Watts CW 10kHz–250MHz Class A Portable Full VSWR– tolerant CE &...
Amplifier Research - 50U1000 - 50 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 50U1000 - 50 Watt CW, 10 kHz - 1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

50 Watts CW 10kHz-1000MHz Class A Portable Full VSWR– tolerant CE & RoHS...
Amplifier Research - 50W1000D - 50 Watt CW, 50-1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 50W1000D - 50 Watt CW, 50-1000 MHz solid-state, self-contained, air-cooled, broadband amplifier

50 Watts CW 50MHz-1000MHz Class A Portable Full VSWR– tolerant CE & RoHS...
Amplifier Research - 5U1000 - 5 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

Amplifier Research - 5U1000 - 5 Watt CW, 10 kHz - 1000 MHz (no remote interface) solid-state, self-contained, air-cooled, broadband amplifier

5 Watts CW 10kHz–1000MHz  

The Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers are the best tools to troubleshoot, quantify energy usage and analyze power distribution systems in a fast, easy and safe way.
  • Measure key power quality parameters: Measures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.
  • Measure with premium accuracy: Meets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.'
  • One-touch reporting: Create standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software using the included Fluke Energy Analyze Plus Software.


Versatile multimeter for manufacturing, development and service applications
  • 5.5 digit resolution
  • Basic V DC accuracy of 0.015%
  • Dual display
  • Dedicated DC leakage current measurement
  • 2 x 4 ohms 4-wire measurement technique
  • Six dedicated buttons for fast access to instrument setups
  • Hi/Lo limit compare for Pass/Fail testing
  • Three-year warranty


  • Reliable, repeatable, accurate device for checking bearings and overall vibration
  • Features innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
  • Provides consistent data quality at both low and high frequency ranges
  • Offers four-level severity scale to assess urgency of problems and bearing condition


These three units beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software, and price. In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes.
Hart dry-wells are easy to calibrate. You don't even have to open the case. This means less maintenance costs and less down time when they do need calibration.
Our Interface-it software lets you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection. The software is written for Windows and has a great graphical interface. Regardless of whether you want basic software or a completely automated calibration system, we've got what you want. Read about all our great packages starting on page 80.
Every dry-well we ship is tested at our factory, and every unit comes with a NIST-traceable calibration. There's no extra charge for the report, because we consider it an essential ingredient in our quality program. You shouldn't have to pay extra for calibration procedures we perform anyway.


  • Accuracy: ≤1/8 in at 30 ft. (≤3 mm @ 10 m)
  • Red beam laser
  • Point Laser Direction: 90° up, down, left, right
  • Horizontal fan angle: 180 °
  • Vertical fan angle: 130°
  • Durable pendulum lock
  • IP54 rating to limit dust and water entry for years of operation on the job site.