Amplifier Research - FA7006/Kit - Electric Field Analyzer Kit, 100 kHz - 6 GHz, 9 - 900 V/m

Amplifier Research - FA7006/Kit - Electric Field Analyzer Kit, 100 kHz - 6 GHz, 9 - 900 V/m

The FA7000 series Field Analyzers are specifically designed to measure modulated electric fields. Each kit provides a web-based, oscilloscope-type display of the instantaneous electric field...
Amplifier Research - FA7040/Kit - Electric Field Analyzer Kit, 2 MHz - 40 GHz, 14 - 1400 V/m

Amplifier Research - FA7040/Kit - Electric Field Analyzer Kit, 2 MHz - 40 GHz, 14 - 1400 V/m

The FA7000 series Field Analyzers are specifically designed to measure modulated electric fields. Each kit provides a web-based, oscilloscope-type display of the instantaneous electric...
Amplifier Research - FA7060/Kit - Electric Field Analyzer Kit, 2 MHz - 60 GHz, 14 - 1400 V/m

Amplifier Research - FA7060/Kit - Electric Field Analyzer Kit, 2 MHz - 60 GHz, 14 - 1400 V/m

The FA7000 series Field Analyzers are specifically designed to measure modulated electric fields. Each kit provides a web-based, oscilloscope-type display of the instantaneous electric field strength...
Amplifier Research - FA7218/Kit - Electric Field Analyzer Kit, 2 MHz - 18 GHz, 14 - 1400 V/m

Amplifier Research - FA7218/Kit - Electric Field Analyzer Kit, 2 MHz - 18 GHz, 14 - 1400 V/m

The FA7000 series Field Analyzers are specifically designed to measure modulated electric fields. Each kit provides a web-based, oscilloscope-type display of the instantaneous electric field...

  • Contact and non-contact thermometer in one
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F) accurate to +1.0°C or +1.0% of reading (whichever is greater)
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments.
  • Offers a distance-to-spot ratio of 50:1
  • Works with most K-type thermocouples


  • Non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection
  • Prevent false readings caused by ghost voltage with selectable low-impedance mode


Fluke CLKT Infrared Windows are Available in Three Sizes 50 mm (2 in), 75 mm (3 in) and 100 mm (4 in) Each CLKT infrared window is engineered and tested to withstand electric-arcs up to 50 kA for 30 cycles. The ClirVu® coating - exclusive to Fluke infrared windows - seals the optic prior to assembly to protect against moisture degradation making it perfect for very hot and very cold outdoor environments. Each Fluke infrared window is delivered with an identification plate attached for unique, on-site numbering for rapid location confirmation and faster repairs. CLKT infrared windows come complete with a security access key, installation instructions and self-adhesive drilling template. For 5 minute or less installation and Autoground consider the CV300.


Fluke CLKT Infrared Windows are Available in Three Sizes 50 mm (2 in), 75 mm (3 in) and 100 mm (4 in) Each CLKT infrared window is engineered and tested to withstand electric-arcs up to 50 kA for 30 cycles. The ClirVu® coating - exclusive to Fluke infrared windows - seals the optic prior to assembly to protect against moisture degradation making it perfect for very hot and very cold outdoor environments. Each Fluke infrared window is delivered with an identification plate attached for unique, on-site numbering for rapid location confirmation and faster repairs. CLKT infrared windows come complete with a security access key, installation instructions and self-adhesive drilling template. For 5 minute or less installation and Autoground consider the CV300.


  • Three-phase power quality recorder with an Android tablet wireless front panel interface
  • Complies with IEC 61000-4-30 Class-A standards for correct evaluation of all measured values
  • Supports quick and reliable configuration even in awkward test locations with the wireless interface that provides a window into what the instrument is recording