Dualos - Fittings - NEO 801F Series
NEO X01 3000 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 801F-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-20 UNJF Class 3A |
1.88 |
- |
- |
|
NEO 801F-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-18 UNJF Class 3A |
1.88 |
- |
- |
| NEO 801F-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-16 UNJF Class 3A |
2.00 |
- |
- |
|
NEO 801F-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-14 UNJF Class 3A |
2.01 |
- |
- |
| NEO 801F-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-12 UNJ Class 3A |
2.13 |
- |
- |
|
NEO 801F-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-12 UNJ Class 3A |
2.20 |
- |
- |
|
NEO 801F-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-12 UNJ Class 3A |
2.20 |
- |
- |
*Approximate Dimensions [inches]
More Product Information
-
On-Off power switch
-
15 A Circuit Breaker
-
Inlet - IEC C14 for use with any cordset
-
Outlets – (8) IEC C13
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
All plugs ship with Skydrol (BMS3-11) Compatible O-Rings, Viton® Cuff and Four Metal Clamps. Parts in compliance with all SMOT document requirements.
- Device and operation are according to the standard IEC 60811-506 (IEC 60811-1-4) point 8.5
- Case set offers all required weights for the test
- Easy operation
- Very robust and solid construction
- Steel impact piece included
- Up to 3 Samples can be tested simultaneously
- Device suitable for positioning in a cold chamber - Product No.: 402.0020.02
- Object size / measuring range up to 130 mm (5.11“) (larger customizations are possible)
- Quick and very easy measurement
- Little training required (without a customer specified database an initial operating instruction takes only 15 min)
- Suitable software: VELOX (measuring software), ProCable3 (CAQ system)
- Various external CAQ software are connectable (CIQ-AESA, ADVARIS, QDA-ASI-DATAMYTE, QUASAR, etc.)
- No user influence on default optical focus as well as default optimized, intelligent and homogeneous lighting
- Shock and vibration resistant due to an optimized sensor arrangement and balanced weight distribution
- Quick and very precise measurements due to the robust construction and easy operation
- Measuring software enables various operator level settings (production, laboratory, administrator, service, etc.)
- Standardized individual components lead to supply security and therefore a short delivery period
- Easy connection with external devices
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors