Elgar - ReFlex Power 875VA AC Power Source Module
- High Power Density (2 VA/cubic inch)
- Single or multi-phase output
- Parallel operation
- 4.8 Crest factor
- Digital control loop technology
- ≥0.95 PFC
- Brown-out simulation
- AC 875 VA
- 45 to 5000 Hz
- Universal AC/DC input via mainframe
- User configurable
- Simple integration
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
Up to 8 mainframes, potentially up to 95 modules, can be controlled via a single controller. The controller communicates to the individual modules via a high speed proprietary bus protocol, providing very high data rates and a high degree of deterministic control. The RFP™ controller communicates to the host controller via an Ethernet LAN connection designed to be compliant with the LAN Extension for Instrumentation ( ™ ) standard, assuring interoperability and ease of integration. RFP™ system modules can be combined via the controller, permitting the creation of “virtual assets” with the voltage/current combinations required for a particular test regime. Creating “virtual assets” reduces the “logistical tail” and total cost of ownership.
Available power modules include
- Single slot, 330 Watt programmable DC supplies
- 16V, 20.6A
- 65V, 5.1A
- Dual slot, 1kW programmable DC supplies
- 33V, 30A
- 50V, 20A
- 50V, 25A
- 120V, 8.3A
- 450V, 2.3
- Triple slot, 875 VA, single phase, programmable AC supply
- Dual range: 280V(rms), 3.5A(rms)
- Dual Range: 140V(rms), 7A(rms)
- Triple slot, 500V, programmable electronic DC loads
- 15A, 375 Watt
- 30A, 750 Watt
The mainframe provides internal power distribution, cabling, I/O and power connection and rack mounting for 12-asset slots. The mainframe also supplies the signal and control bus fabric supporting multi-module series/parallel operation, complex triggering, fault I/O and inter-mainframe control infrastructure.
AC Power Modules General Specifications |
|
---|---|
Current, Maximum |
140V Range 7A, not to exceed 875 VA, Overload 10A for 0.5 Seconds |
Current, Maximum |
280V Range 3.5A, not to exceed 875 VA, Overload 5A for 0.5 Seconds |
Frequency |
45-1200 Hz, up to 5 kHz optional |
Crest Factor |
4.8 X FS rms current |
Load Regulation |
100% Resistive Load effect (<100 msec) Voltage Mode 0.5% of FS Current Mode 0.1% of FS |
Line Regulation |
10% Line effect (< 100ms) Voltage Mode 0.1% of FS Current Mode 0.1% of FS |
Programming Accuracy |
Voltage 0.1% of FS + .2%/kHz Current +/-(0.5% + 0.75%/kHz) of full-scale Frequency 0.01% of setpoint |
Programming Resolution |
Voltage 0-140VAC 9mV, 0-280 18mV Current 2.2mA Frequency 0.1Hz thru 1kHz; 0.5Hz thru 5KHz |
Temperature Coefficient |
Voltage .05% of FS per °C Current .05% of FS per °C |
Distortion |
<1% to 500Hz <2% to 2KHz <5% to 5KHz |
Output DC Offset |
±0.1Vdc maximum |
Efficiency |
72% |
RMS Noise |
55dB below full-scale Input (via RFP Mainframe) Inrush Current 8.8A at 115Vac; 17.6A at 230Vac 14.6A at 270Vdc |
Power Factor |
0.95 typical |
Hold-up Time |
10ms |
Remote Sense |
0.75Vrms per line Input |
Overvoltage Protection |
Range: 1.4% to 110% Accuracy: 2% of setpoint |
Overcurrent Protection |
Range: 0.4% to 106% Accuracy: 3% of setpoint |
Auxiliary AC Output |
Isolated 0Vac to 31.6Vac, 2A max proportional to AC output |
Cooling |
Forced air convection, req. 40CFM airflow at altitude and ambient temperature |
Multi Phase Parallel |
Up to 6 in a group |
Phase Programming Range |
0-360 degree; counterclockwise phasor rotation is assumed, therefore the phase angle offset is lagging the master reference. |
Phase Programing Accuracy |
1 degree plus 1°C/kHz for balanced resistive load measured with respect to A-phase, at 25 degree C, +/- 5 degree. |
Remote Programming Connector |
9-pin D-sub |
Output Connector |
Combination signal/power contact subminiature D (Mating connector kit available) |
Physical |
3 RFP™ slots wide 4.2” (106.7mm) W 6.75” (171.5mm) H 15” (381 mm) D |
Weight |
13 lbs (5.9 Kilograms) |
All specifications: 25°±5°C.
All specifications are subject to change