IntelliPower - FA00162 Rugged UPS
-
AC Input UPS with internal batteries, extreme high temperature rugged rack mount double conversion on line UPS 72VDC in and 120VAC out at 60Hz with for Industrial Applications in a 2U enclosure
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 2U, ≤23"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | ≥ 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
1100Va, 1000W, 120Vac 60Hz Input, 120Vac 60Hz 600Va 500W Non-Isolated Output, 28Vdc 500W Isolated Output, Freq Changer, No Battery, 1U24, Aluminum, IEC-C14, SNMP, 3 x NEMA
-
2500VA, 2000W, 115VAC 60Hz Input and 115VAC 60Hz Output, Double Conversion, Rugged, On-Line UPS with Power Factor Correction for Military Applications
-
Ease of installation, simple and repeatable
-
Rugged, multipoint monitoring; up to 256 sensors on a single HYPERION instrument
-
Ultra high resolution
-
Multiparameter various physical parameters measurements coupled onto the same instrumentation platform
-
Internally temperature compensated
-
800VA, 560W, 120VAC 60Hz Input and 120VAC 60Hz Output, Frequency Changer, Non-Isolated, Power Factor Corrected, 2U Rack Unit, 3.5" High x 17" Wide x 17" Deep, Rugged, Double Conversion, to Provide Power Conditioning and Hot Swap Battery Hold-up for Industrial Applications
-
1500VA, 1000W, 2 EA 115VAC, 60Hz Input & 115VAC, 60Hz, Outputs, Double Conversion, Rugged, High Temperature, Isolated, On -Line UPS System with Hot Swap Battery, Power Factor Correction and Discrete, Parallel Line Communications
-
5KVA, 4KW Double Conversion On-Line Isolated. 230VAC, 50/60Hz Input UPS with 230VAC, 60Hz Output, Frequency Conversion, Power Factor Correction and SNMP Communications for Military Applications
These rugged, dependable high gain log periodic antennas give you the constant high intensity fields you need for RFI and EMI testing in and out of a shielded room. They deliver frequency response and field intensity beyond the norm. AR’s log periodics are designed for high power radiated testing and can be calibrated for emissions.
Their lightweight modular design makes assembly and relocation easy. And they’re built tough, so they can withstand extreme temperatures.
-
2-Drawer battery pack needs to be split (2 outputs 1 for each UPS) via Anderson connections
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form