2500 VA, 2000 W, Global Auto Select 120 or 240 VAC, 50/60 Hz Input and 120 VAC, 50/60 Hz Output, Double Conversion On-Line, High Temperature, 5 each 12V10EB, Lithium Iron Phosphate, Hot Swap Battery Drawer, Rugged UPS with Power Factor Correction for Military
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 2U, ≤23"D |
Input Voltage | 208 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | < 20 minutes |
Battery Chemistry | Lithium Iron Phosphate |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
Power Conditioner 3000VA, 3000W, Isolated, 220VAC at 50 Hz Input, and 220VAC at 60Hz Output
-
2000 VA, 1400 Watts, Input at 120 VAC (-20% + 15%), 50/60 Hz, Output at 120 VAC, 50/60 Hz follower, Double Conversion, Non Isolated, Rugged UPS with Power Factor Correction
-
UPS: 6000VA, 4800W, 220Vac 50Hz Isolated Input, 220Vac 50Hz Output. Freq Changer, EBP, 3U25.6, Aluminum, Cir Mil, SNMP, Relay Output, 2 x 2x2 Anderson, 2 x Cir Mil
-
IntelliPower Rack Mount Input Isolation Transformer for 120VAC Input and Output. Includes surge protection
-
230Vac Input, L6-30P1 on 43.5 Power Cord, L6-15R10 Output, Each Output having a Circuit/Switch control, 1U9.5, Aluminum
-
Global Input, Rugged, Rack Mount, Double Conversion On Line UPS & Isolated Power Conditioning System with Frequency Conversion, Auto-select Input Voltage Select, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 1U Enclosure
-
6000VA, 4500W, 85-265VAC, 50/60Hz Input and 220 or 230VAC, 60Hz Output, Freq Changer, 3U25.6, Hubbell IEC 60309 460P12W on 3ft Cord, L6-30R on 3ft Cord, Double conversion, Rugged, High Temperature, Isolated, On-line UPS, Power Factor Correction, External EBM
-
3000VA, 2600W, 120VAC, 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction
-
5000VA, 4500W, 240VAC 50/60Hz Input and 240VAC, 60Hz Output, Double Conversion, Rugged, High Temperature, Isolated, On Line UPS System with Power Factor Correction for Military Applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form