VTI Instruments - SMX-5xxx series of General Purpose Switches
The SMX-5xxx product family includes the SMX-5001 and SMX-5002.
The VTI SMX-5xxx Series of general purpose switches deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Embedded virtual schematic control simplifies setup and debugging, allowing all relays to be engaged independent of application software and device drivers.
Ideally suited for a wide range of discrete signal switching, the SMX-5xxx Series provides uncompromised measurement integrity ideal for the most demanding aerospace, defense and automotive automated test equipment (ATE) applications.
|
SMX-5001 |
(80) SPST/Form A |
|---|---|
|
SMX-5002 |
(50) SPDT/Form C |
|
SMX-5004 |
(30) SPDT/Form C |
More Product Information
- 8 frequency counter channels, 16 isolated digital I/O channels, 2 isolated DAC channels in a single card
- Single frequency measurement range that works from 0.05 Hz to 1 MHz
- Very stable TCXO base clock, 50 MHz ±1 ppm
- 195 kΩ Input impedance with selectable coupling (AC/DC)
- Wide differential input voltage range (±48 V) with up to 250 V working common mode voltage
- Programmable threshold and hysteresis levels with 1 mV resolution
- Support for quadrature encoder
- Isolated DIO channels with up to 60 V compliance
- Isolated and independent 16-bit DAC channels, configurable for voltage or current output
- Typical accuracies of ±0.20°C
- 16-channel isolated universal thermocouple/voltage inputs
- Power over Ethernet+ (PoE+)
- 20K samples/second/channel sample rate
- 24-bit ADC per channel
- 500 V channel-ground isolation
- 1000 V channel-channel isolation
- Data logger acquisition mode
- Built-in parallel data streaming
- Full-featured embedded web interface
- LXI Ethernet interface
- 8-bit bank isolated digital I/O
- Compact 1U half-rack form factor
- Eight channel, universal, 2-/4-wire RTD simulator
- Fast, monotonic, glitch-free resistance value programming
- Suitable for simulating resistors, platinum/copper/nickel RTDs
- Suitable for pulsed and continuous excitation inputs
- Direct temperature value programming
- Extensive triggering capability
- Synchronize level changes with input measurements to facilitate test sequencing
- High power density in 1U / 2U / 4U / 14U chassis up to 18kVA
- Intuitive touch panel control
- Innovative iX2™ current doubling technology
- Multi-language display for global operation
- Auto paralleling for higher power
- Single phase 1U models and 1 or 3 phase selectable 2U / 4U / 14U models
- Complete avionic test suites (optional)
- ATE version available in 1U, 2U and 4U models
- Standard LXI LAN, USB and RS232, optional GPIB
- Legacy CSW5550 Emulation on the AST6003A1 Model
- Highest resolution – 12 bits all the time
- More capability – integrates multiple instruments into one
- Comprehensive probe support – supports over 30 probes in 9 categories
- MAUI with OneTouch user interface for intuitive and efficient operation
Optimized Measurement Setup
- Multi-purpose SIGMA instrument integration kit
- Shorter cabling and universal chuck connection
- Triax probe with protected guard
- Optimized signal path
- Safe probe tip exchange
- Seamless integration of various analyzers
High Power Chuck
- Triax design for low-leakage measurements up to 3 kV
- Special chuck surface coating
- High-isolation ready
- High-current measurement up to 100 A with lowest contact resistance
- Optional upgrade for 10 kV (coax) operating voltage
- Thin wafer handling capability
Safe Operation
- Arcing protection
- Shield Enclosure with interlock
- Advanced grounding concept
- Maximum protection from high-voltage shock for users and devices
- Common ground protection for all instruments
- EMI/light-tight shielded environment
- Large switching capacity in a small footprint
- Switch up to 16 A current - highest in its class
- High breakdown voltage (1,000 V rms between open contacts)
- Ideal for applications such as high current/high power switching, AC line power switching, driving relays for industrial machinery, solenoid switching, and automotive engine control
- Fail-safe interrupt inputs that can detect a fault condition automatically open up relays to their default state
- 8 frequency counter channels, 16 isolated digital I/O channels, 2 isolated DAC channels in a single card
- Single frequency measurement range that works from 0.05 Hz to 1 MHz
- Very stable TCXO base clock, 50 MHz ±1 ppm
- 195 kΩ Input impedance with selectable coupling (AC/DC)
- Wide differential input voltage range (±48 V) with up to 250 V working common mode voltage
- Programmable threshold and hysteresis levels with 1 mV resolution
- Support for quadrature encoder
- Isolated DIO channels with up to 60 V compliance
- Isolated and independent 16-bit DAC channels, configurable for voltage or current output
VXI Chassis include 6-slot VXIbus mainframes (CT-100C), 5-slot VXIbus mainframes (CT-310A), and modular 13-slot VXIbus mainframes (CT-400, pictured).
VTI Instruments