Data Acquisition Systems (DAQ)

Products

VTI Instruments - APEX Turbine Data System (DS)
The APEX Turbine Data System (DS) is the next generation of data acquisition, control, setup, and online analysis. It reliably acquires time-synchronized data from a network of digitizers, regardless of sample rate or sensor type.

VTI Instruments - EX10XX Series thermocouple and voltage measurement instruments
  • High-density, compact (1U) precision data acquisition instruments
  • LXI™ LAN connectivity
  • Fully integrated signal conditioning maximizes performance and accuracy
  • Easily integrate thermocouples, voltages, RTDs, thermistors, frequency, strain and pressure on an per-channel basis
  • Distributed, synchronized measurements over the wire
  • Scalable architecture easily expands from tens to thousands of channels
  • DC version available for test cells requiring closer proximity to test article
  • End-to-end self-calibration ensures optimum runtime performance
  • Web-based access for monitoring and control
  • Exlab turnkey software for simplified setup, control and data display

VTI Instruments - EX1403A - 16-Channel bridge and strain gauge measurement instrument
  • 24-bit, delta-sigma ADC, simultaneous sampling
  • Programmable Sample Rate up to 128kSPS
  • Full, Half & Quarter Bridge with 120Ω, 350Ω & 1kΩ bridge completion
  • Voltage Excitation: 0.5V to 10V
  • Current Excitation: 0.46mA
  • 2-Wire & 4-Wire Ohms/RTD
  • Bridge Zero Balancing
  • Built-In-Self-Test (BIST)
  • Strain Lead Wire Calibration
  • Shunt Calibration: 50kΩ, 100kΩ & External provided by User
  • TEDS Support
  • LXI Ethernet Interface
  • IEEE-1588 Synchronization
  • Power over Ethernet (PoE) or 10–50 V DC input
  • Built-in Parallel Data Streaming
  • Full-featured Embedded Web Interface
  • Compact 1U Half-rack Form Factor


  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture


Installs and grounds in less than 5 minutes
Save time with quick and easy installation with the CV Series – 5 minutes or less.
  • One technician
  • One hole with standard Greenlee® punch
  • Panel door does not need to be removed
  • Grounds instantly to metal enclosure with patent-pending AutoGround™ process
  • Maintains panel arc test ratings up to 63kA when properly installed
Work more efficiently with Fluke ClirVu® CV201 50 mm (2 in) Infrared Windows
  • NFPA 70E processes significantly reduced due to less work permit requirements
  • Faster and more comfortable inspections because full PPE is often not required
  • Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
  • CV201 is Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
  • Convenience of both quick turn or security keyed access


The 438-II Power Quality Analyzer & Motor Analyzer helps you effectively evaluate electrical and mechanical performance just by hooking up voltage and measuring current, providing you with an unprecedented level of data.
  • Brings key motor analysis parameters like speed, torque and mechanical power and calculates motor efficiency without mechanical sensors
  • Includes full power quality and electrical energy analyzer functionality
  • Highest safety rating in industry; 1000 V CAT III / 600 V CAT IV


  • Power quality that meets the standard All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc.
  • Quick and reliable configuration A tablet computer provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
  • Threshold-free set up Apply thresholds after data is collected with Fluke Power Analyze Software – no need to worry about missed information due to incorrect setups
  • Captures everything Cross-channel and current triggering capture every measurement, on every channel, every time
  • Intuitive PC software Easily analyze data and generate reports with automated EN50160 reporting and compliance
  • Reporting has never been easier Auto Report creates either standard reports or customized reports with the minimum effort or hassle. Export reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.
  • Plug and play Set up in minutes with self-identifying current probes and single-lead voltage connections
  • No need to reconnect wires Swap channels internally with the wireless PDA or PC when connections are not correct
  • Measure every parameter Voltage and current on three phases, neutral, and ground
  • 5 MHz, 8000 Vpk waveform capture Get a detailed picture of even the shortest events
  • Quickly retrieve data With included SD memory card or via the 100 BaseT high-speed Ethernet connection. SD card includes automatic download to SD when no other connection is made to the instrument


  • Four electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • Choose from 60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth models
  • Fast sampling rate, up to 5 GS/s with up to 200 ps resolution (Depending on model and channels used)
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 999 Count digital multimeter.