Advanced Illumination - SL112 Series Medium Intensity Spot/Coaxial Light
- The SL112 is characterized as a Medium Intensity Spot/Coaxial Light and is designed primarily to replace fiber optic light sources in coaxial lensing applications.
- Optional couplers are available for use with Dolan-Jenner, Fostec, and Moritex fiber bundles.
- The spot light is designed with sufficient thermal management to provide 22kLux at a working distance of 4” (100mm).
- A range of visible wavelengths are available
General Specs
|
Electrical Specifications |
Color |
24V Current |
All Other Controls |
|---|---|---|---|
|
625 |
N/A |
0.11 A Max |
|
|
WHI, 470, 530, 590 |
N/A |
0.28 A Max |
|
|
Normal Operating Temperature |
0 - 60°C |
||
|
Weight |
39.7g (1.4oz) | ||
|
Standard Cable Information |
2 m long -0/+150 mm (80" -0/+6") - 105°C rated PVC jacket, foil shield with drain. |
||
|
Photobiological Risk Factor |
Group 1 (Low-Risk) Applicable Wavelengths: WHI, 470, 530, 590, 625 | ||
|
Compliance |
CE, RoHS, IEC 62471 |
||
|
IP Rating |
IP50 |
||
|
Lumen Maintenance |
L70 = 50,000 Hours |
||
Mechanical Specs
Optical Specs
Electrical Specs
Control Specs
Part Number Key

More Product Information
- Our classic LL163 Line Lights are suitable for low intensity, low speed line scan applications.
- These line lights are well established and have proven reliability.
- Provides a intensity level of 24kLux (working distance of 25mm).
- Available in 7 wavelengths including 395nm (UV) and 880nm (IR).
- Pre-engineered for expandability in 1.5” (38.1mm) increments up to 81” (2.06m).
- LL163 derivatives include LL2912 (3”), LL3024 (6”) and LL3148 (12”) (which represent legacy part numbers)
The LL330 Series provides a sealed high intensity line light solution for demanding industrial environments. Engineered to withstand harsh conditions, these line lights are completely protected from dust and debris, ensuring reliable performance where other lights fail. In addition, passive thermal management eliminates the need for active cooling fans, contributing to low-maintenance, long-term operation.
The LL330 is available with an embedded control option, designed for continuous operation and housed within the configured light head. With options for converging or collimating optics, this series is suited for a variety of application needs. The LL330 is ideal for sheetrock, lumber, ceramics, stone, and other industries utilizing line scan imaging where airborne particulate, dust, and debris are concerns.
- 1-slot 1U allows high-port density in a robust form factor
- Price/performance
- Ease of use
- Advanced architecture
- User-friendly software (XenaManager, Xena OpenAutomation)
- Test automation with XOA
- Three years’ software updates
- Three years’ hardware warranty
- Free tech support & training for the product lifetime
- High-Intensity Illumination in a Compact Package
- Available in a broad range of wavelengths
- Washdown Version Available
- Convenient M4 T-Slot for Mounting
- The Direct PC bus access data acquisition system provides the required sampling rate and resolution to meet IEC 61000-4-7 measurement requirements and supports high-speed data transfers.
- PC-based Harmonic and Flicker test software provides real-time full-color data display updates and continuous PASS/FAIL monitoring.
- Automatic calculation of the maximum permissible system impedance Zsys, using the Zref and measured Flicker parameters, as required per EN/IEC 61000-3-11.
- Intuitive operating software provides IEC test setup, data analysis, display, with test reports in and MS Word format.
- High resolution, no gap acquisition data storage to ensure that all data can be streamed to disk (in ASCII format if needed) for later review and replay of the actual test.
- Single Step and Fast playback mode of test results.
- The BL128 Series provides a compact linear backlight solution ideal for space-constrained line scan applications.
- Its ultra-thin profile (less than ½”) minimizes vertical footprint, and bezel-free design along the length allows for placement of its emitting window right up to adjacent surfaces.
- While optimized for line scan setups, the BL128’s versatility extends to general-purpose machine vision lighting as a non-directional, highly diffuse bar light illuminator when needed.
- IRIG’s A and B and NASA 36 time code inputs
- +3.3V or +5V signalling
- 1PPS Sync input
- External Event (Time Tag) input
- Three programmable pulse rate outputs
- Match Time output
- Industrial Temperature Range option
- Optional on-board GPS option
- Optional HaveQuick input/output
- Optional IRIG B time code output
- The RL1424 is characterized as a Small Aimed Bright Field ring light.
- Precisely aimed LEDs provide a level of lighting control not found in traditional illuminators.
- A range of standoffs and fields of view may be specified at the time of order.
- The RL1424 is available in a wide range of wavelengths from UV to IR.
- Diffuser and polarizer options are also available.
- The large inner diameter of the ring light can accommodate lenses up to 55mm in diameter.
- The light can also be ordered with a variety of mounting options.
- The SL2507 is characterized as a Small Aimed Spot Light.
- Precisely aimed LEDs provide a level of lighting control not found in traditional illuminators.
- A range of standoffs and fields of view may be specified at the time of order.
- The spot light is available in a wide range of wavelengths from UV to IR.
- Diffuser and polarizer options are also available.
- The SL2507 provides 2.6kLux at a working distance of 4” (100mm).
Advanced Illumination
Machine Vision Lighting Solutions