Advanced Illumination - MP-ICS - Manual Dimming Accessory
- 0 – 100% intensity control
- For use with lights built with an ICS 2 after 3/1/2012
- NOT COMPATIBLE with LLI37, BLI38, LLI67, and BLI68 “IC” Lights
General Specs
|
Length |
89.0mm (3.50in) |
|---|---|
|
Width |
60.2mm (2.37in) |
|
Height |
53.8mm (2.12in) |
|
Weight |
59.5g |
|
Operating Temperature |
-25°C to 57°C |
|
Compliance |
CE, RoHS |
Mechanical Specs

Electrical Specs

Part Number Key

More Product Information
- For applications requiring power cables longer than the standard 2 meters provided with Ai lights.
- Standard cable lengths are 3, 5, 9 and 15 meters.
The overall performance of a power meter dependents on the power sensor employed. Maury has a variety of quality power sensors to meet virtually all applications. Maury has a complete line of Peak and Average power sensors up to 40 GHz for all of your fast rise time, wide bandwidth and wide dynamic range applications. In this document, browse through our large variety of advanced sensor solutions.
- Guaranteed performance to 43.5 GHz with Extended K™ ports
- High output power allows measurement of high attenuation devices
- Wide dynamic range enables measurement of very low reflection artifacts
- Excellent corrected directivity minimizes measurement uncertainty
- SmartCal™ auto calibration unit reduces calibration and setup time
- Time domain with time gating option grants easier and faster fault identification
- Modern LAN interface for remote control is faster than GPIB
- A common GUI and SCPI interface within the ShockLine family
- Bias tee option simplifies test setups where the DUT needs DC biasing
- Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
- E-Band VNA
- Extended frequency range covering E-band and major parts of V band
- Fully assembled test system eliminates setup errors and increases reliability
- Tethered modules connect directly to the DUT increasing measurement stability
- The LL137 Series provides a focused line of illumination in a passively cooled design.
- Provides a medium intensity level of 280kLux (working distance of 75mm)
- Pre-engineered for expandability in 6” (152mm) increments up to 96” (2.44m).
- Available intensity control provides illuminance adjustability for every 6″ increment via a 0 – 10v input
Note: If only looking for white illumination, our LL167 Series provides a 74% brighter beam in a similar package.
- Repeatable high product quality due to automated production processes
- Optical output power up to 2500 mW
- Manually focusable
- Active cooling integrated
- TTL modulation up to 200 kHz
- Analog intensity control
- IP 67
- Certified according to the railway standard: DIN EN 61373:2011-04
- PC control via Graphical User Interface (GUI)
The ZQ1 HighPower is a performance-optimized laser module designed for demanding imaging and measurement applications. With up to 2.5 W optical output and available wavelengths of 760 nm, 808 nm, and 450 nm, it offers maximum flexibility for industrial sensing, analytics, and medical technology. The 762 nm diode in particular delivers a significantly improved signal-to-noise ratio, higher camera sensitivity, and reduced ambient light effects—making it ideal for outdoor measurements and daylight conditions. Typical applications range from 3D triangulation and infrastructure inspections (road and rail) to spectroscopy, precision metrology, and medical procedures. With its robust thermal design, active stabilization, and OEM options, the ZQ1 HighPower is built for reliable performance in both industrial and outdoor environments.
Our EuroBrite™ lineup provides industry leading technology with value pricing for an unmatched performance / price ratio:
- Complete built-in control for continuous and strobe modes.
- Adaptive Power™, a feature of the EuroBrite™ lighting controller, utilizes an onboard thermistor to maximize light output in continuous mode.
- Adaptive Overdrive,™ another feature of the EuroBrite™ lighting controller, provides a maximal output pulse in strobe mode regardless of the exposure period.
- IP67 sealed enclosure suitable for washdown environments.
- Rugged construction that has been tested to withstand over 1000lb.
- Industrial grade LEDs providing high-intensity illumination of 45klux (working distance of 200mm).
- Daisy chain up to 4 for a combined length of 48”.
- 1.3" (24 mm) max. sensor size
- C-Mount lens and TFL-Mount lens available
- 2 focal lengths: 28 mm and 35 mm
- Initial aperture: F2
- Ruggedized version for 28 mm lens
- Motorized iris available for 28 mm lens
The BARCUDA VP230 is the right system if you are looking for a complete turnkey solution for flexible testing and programming of your electronic assemblies. The stand-alone unit uses the technologies of embedded JTAG solutions such as VarioTAP or ChipVORX. However, you can also expand these to meet the functional test requirements of your electronics production.
With BARCUDA VP230 you can test and program assemblies with or without JTAG/Boundary Scan - with no need to configure a special in-house test system.
With a standard, robust interface "VPC G12 Receiver" from Virginia Panel Corporation (VPC), you can choose the adapter supplier (for needle bed adapters) for contacting your assembly and implement any mechanical requirements.
BARCUDA VP230 is equipped with a complete power-up unit and TAP control for 16 boards, which can be scaled up to 32 boards. It can also be expanded with analogue measurement cards, additional I/O channels and your specific hardware.
- The SL164 is characterized as a Compact High Intensity Spot Light with sufficient thermal management to provide 200kLux at a working distance of 4” (100mm).
- A very wide range of wavelengths are available from UV to IR.
- Multiple beam spreads are also available as is a diffuser option.
Advanced Illumination
Machine Vision Lighting Solutions