HYPERLABS - Frequency Dividers
The HL590x series is a wideband frequency divider with minimal additive phase noise. It supports division ratios of 2, 4, 8, depending on the model, from 100 MHz to 24 GHz.
|
Frequency Dividers |
HL5902 Frequency Divider (100 MHz to 24 GHz) The HL5902 Series is a wideband frequency divider with minimal additive phase noise, supporting divide ratios of 2, 4, and 8 from 100 MHz to 24 GHz. It delivers buffered outputs from 12.5 MHz to 12 GHz at a typical 2 dBm output power and operates from -40° to +85°C with internal regulation supporting +7 to 16 VDC supplies. |
|---|
More Product Information
The HL945x family of transition time converters (also known as low-pass absorptive rise time filters) provide superior return loss and flat group delay.
DC Blocks from HYPERLABS offer low insertion loss of up to 145 GHz. These parts are available in a variety of connector configurations and with various breakdown voltage and capacitance options.
-
A wide frequency range eliminating the need for antenna changes
-
30W maximum power input allows high filed strengths
-
High efficiency due to a low VSWR and high gain
-
Suitable for broadband digital modulation thanks to a good VSWR flatness
-
Small, light-weight and flat antenna easy to use in narrow spaces
-
Easy handling with a flexible arm
-
A wide radiation pattern makes directivity of the fields no longer an issue
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.
- 5 MHz or 10 MHz Outputs Available
- Reference Frequency Input Option
- Auto Changeover with Ref. Input Option
- Low Phase Noise Outputs
- Twenty four Outputs
- Front Panel Status Indicators
- Fault Discrete Inputs
- Compact 1U, 19” rack mount
Bank of fixed resistance, capacitance and inductance standards with defined frequency characteristic up to 1 MHz for automated calibration of LCR meters.
- Automated RCL calibration
- Calibration data from 20 Hz to 1 MHz
- No need for pen and paper method
- 6U, Single Width VME
- Time Code Inputs
- Time Code Output
- 1PPS Pulse Rate Output/Interrupt
- Frequency Outputs (1, 5, 10 MHz)
- External Event Capture/Interrupt
- Programmable Periodic Output/Interrupt
- Programmable Time Strobe Output/Interrupt
The SMP1xxx product family is made up of the SMP1100 and the SMP1200 (pictured).
HYPERLABS offers ultra-broadband 50 Ω load terminations from DC to 110 GHz.
HYPERLABS, Inc.
Founded in 1992, HYPERLABS is a leading designer and manufacturer of 145+ GHz Ultra-Broadband Baluns, DC Blocks, Pick-Off Tees, Bias Tees, and other high-performance components.
We also build TDR and Signal Integrity instruments used in the test and measurement industry. Our product line includes high-speed and electrostatic-protected instruments, all in low-power, portable form factors that can be controlled from any Windows PC.