IntelliPower - Rugged UPS
See "Specifications & Details" tab for more details
Rugged UPS FA00001 |
|
---|---|
Global Input, Rugged, Rack Mount, Double Conversion On Line UPS & Isolated Power Conditioning System with Frequency Conversion, Auto-select Input Voltage Select, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 1U Enclosure. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
115 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00002 |
|
---|---|
2000VA, 1800W 120/240VAC & 28DC Input & 120VAC,60Hz Output, Double Conversion, Rugged, High Temperature, Isolated, Online UPS System with Hot Swap Battery, Frequency Conversion, Power Factor Conversion and SNMP Communications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00005 |
|
---|---|
1500VA, 1050W Global 120/230VAC Input 120VAC 60Hz Output, Isolated High Temp, Rack Mount UPS. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 230 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00007 |
|
---|---|
High Temperature, Double Conversion, Rugged, Isolated, Rack Mounted UPS System with Power Factor Correction for Navy Shipboard Applications. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
115 VAC |
Input Connector |
Circular Mil |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00008 |
|
---|---|
High Temperature, Double Conversion, Rugged, Isolated, Rack Mounted UPS System with Power Factor Correction for Navy Shipboard Applications. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00009 |
|
---|---|
Double Conversion, Rugged, Isolated, On Line UPS System with Frequency Conversion and Power Factor Correction. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
Vertical-Free Standing |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00010 |
|
---|---|
3KVA, 2.1KW double conversion, online, isolated, global input, rugged UPS with 120vac output, frequency conversion, power factor correction and extended internal batteries for military applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
230 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
SNMP |
Rugged UPS FA00013 |
|
---|---|
3KVA, 2.1KW double conversion, online, isolated, global input, rugged UPS with 120vac output, frequency conversion, power factor correction and extended internal batteries for military applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00018 |
|
---|---|
Double Conversion, Rugged, High Temperature, Isolated, On Line UPS in 3U-20.63”D Rack Mountable Enclosure with Power Factor Correction, Cold Start, SNMP, 120VAC, 50/60Hz Input and 120VAC, 60Hz Output. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
Pigtail |
Output Connector |
Pigtail |
Communication |
SNMP |
Rugged UPS FA00019 |
|
---|---|
5KVA, 4KW Double Conversion On-Line Isolated. 230VAC, 50/60Hz Input UPS with 230VAC, 60Hz Output, Frequency Conversion, Power Factor Correction and SNMP Communications for Military Applications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
230 VAC |
Output Voltage |
230 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
SNMP |
Rugged UPS FA00023 |
|
---|---|
1500VA, 1050W Global 120/230VAC Input 120VAC 60Hz Output, Isolated High Temp, Rack Mount UPS. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 oR 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00024 |
|
---|---|
1100 VA, 750 W, 120/230Vac 50/60Hz Global Isolation Input, 120Vac 60Hz Output UPS with Power Factor Correction. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 230 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00026 |
|
---|---|
Rugged, Double Conversion, 208VAC Input and 230VAC Output, Online UPS System with Power Factor Correction. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
208 VAC |
Output Voltage |
230 VAC |
Input Connector |
IEC |
Communication |
RS232 |
Rugged UPS FA00028 |
|
---|---|
Rugged, Double Conversion, High Temperature, Isolated, Auto Select 120/240VAC, Global Input & 120VAC Output, On Line UPS System & Power Conditioner with Power Factor Correction. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
IEC |
Communication |
RS232 |
Rugged UPS FA00029 |
|
---|---|
1.5VA, 1.03kW, Isolated, Sealed IP65, Double Conversion, On-Line UPS with 120VAC, 60Hz Input, 24VDC Output, Power Factor Correction for Navy Shipboard Applications in a 2U Enclosure. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
None |
Rugged UPS FA00031 |
|
---|---|
2000VA, 1500W, 115VAC 50/60Hz Input and 120VAC, 50/60Hz Output, Double Conversion, Isolated, Rugged, High Temperature, Online UPS with Power Factor Correction for Navy Shipboard Applications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
SNMP |
Rugged UPS FA00037 |
|
---|---|
Rugged, high temperature, rack mount, double conversion on line UPS with frequency conversion and power factor correction for tactical military applications with cold start function and extended internal batteries. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00038 |
|
---|---|
Rugged, high temperature, rack mount, double conversion on line UPS with frequency conversion and power factor correction for tactical military applications with cold start function and extended internal batteries. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
Vertical-Free Standing |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00040 |
|
---|---|
IntelliPower rack mount, isolated, global input, double conversion on-line UPS. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
115 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00041 |
|
---|---|
Double Conversion, Vertical/Free Standing, Online UPS System with Power Factor Correction. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
230 VAC |
Output Voltage |
230 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00048 |
|
---|---|
1100VA, 800W, Auto Select 120VAC or 240VAC, 50/60Hz Input and 120VAC,50/60Hz Output, Double Conversion, Rugged, High Temp, On Line UPS with Power Factor Correction for Military Applications. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00049 |
|
---|---|
Rugged, Double Conversion, Global Input, Isolated, Online UPS System with Power Factor Conversion and Frequency Conversion for Land Based Military Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00056 |
|
---|---|
2000 VA, 1400 Watts, Input at 120 VAC (-20% + 15%), 50/60 Hz, Output at 120 VAC, 50/60 Hz follower, Double Conversion, Non Isolated, Rugged UPS with Power Factor Correction. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
Terminal Block |
Communication |
RS232 |
Rugged UPS FA00065 |
|
---|---|
Rugged, Double Conversion, Global Input, Isolated, Online UPS System with Power Factor Correction and Frequency Conversion with SNMP Interface for Industrial Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00071 |
|
---|---|
3000VA, 2.1KW, 115 VAC 50/60 Hz Input, 115 VAC, 60 Hz Output, Frequency Changer, Galvanic Isolation, Power Factor Corrected, Rack Unit, 3U High x 19" Wide x 16.75" Deep, Panel Mounted Power Connectors, Rugged, Double Conversion UPS, to Provide Power Conditioning and Battery Hold-up for Shipboard Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
115 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
None |
Rugged UPS FA00072 |
|
---|---|
3000VA, 2.1KW, 115 VAC 50/60 Hz Input, 115 VAC, 60 Hz Output, Frequency Changer, Galvanic Isolation, Power Factor Corrected, Rack Unit, 3U High x 19" Wide x 16.75" Deep, Strain Relieved Power Cables, Rugged, Double Conversion UPS, to Provide Power Conditioning and Battery Hold-up for Shipboard Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
115 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
None |
Rugged UPS FA00092 |
|
---|---|
High Temperature, Double Conversion, Online UPS System with Power Factor Correction, Frequency Conversion and 2 ea. 12V7AH High Temp Batteries for Industrial Applications. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
Terminal Block |
Output Connector |
Terminal Block |
Communication |
RS232 |
Rugged UPS FA00095 |
|
---|---|
3000 VA, 3000 Watts, input AC 120 or 240 VAC (-10%+15%), input frequency 40 to 70 Hz, Input and Output AC, 120 or 240 VAC (-10% + 15%); 120 VAC (+/-3%) output frequency 60 Hz, (+/-3 Hz), Double Conversion, On-Line, Isolated, Rugged UPS with Power Factor Correction for military Applications. |
|
Power Rating |
2700--6000 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00098 |
|
---|---|
Global Input, Double Conversion, Rugged, High Temperature, Isolated, Online UPS System with Hot Swap Battery, Power Factor Correction and MIL STDs |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
115 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
None |
Rugged UPS FA00099 |
|
---|---|
AC input with internal batteries, extreme high temperature, rugged, double conversion UPS with 72VDC in and 120VAC out at 60 Hz for industrial applications in a 2U enclosure. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00116 |
|
---|---|
Rack Mount, Double Conversion, Online UPS with Power Factor Correction. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
Vertical-Free Standing |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00121 |
|
---|---|
Global Input, Rugged, Rack Mount Double Conversion Online UPS and Isolated Power Conditioning System with Power Factor Correction, Frequency Conversion, Auto Select Input Voltage Selection in a 2U enclosure. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00123 |
|
---|---|
3kVA, 2.1kW Double Conversion On-Line Isolated UPS 115VAC, 60Hz Input, 120VAC, 60Hz Output, Power Factor Correction, Multiple Relay Contact Status Signals and Internal Automatic Bypass for Navy Shipboard Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
RS232 |
Rugged UPS FA00124 |
|
---|---|
3KVA, 3.0KW Double Conversion, On-Line, Isolated, UPS with 115VAC, 60Hz Input, 120VAC, 60Hz Output, Power Factor Correction, Multiple Relay Contact Status Signals and Internal Automatic Bypass for Navy Shipboard Applications. |
|
Power Rating |
2700-6000 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
RS232 |
Rugged UPS FA00126 |
|
---|---|
3KVA, 2.6KW Double Conversion On Line Isolated UPS with 115VAC, 60Hz Input, 120VAC, 60Hz Output, Power Factor Correction, Multiple Relay Contact Status Signals and Internal Automatic Bypass for Navy Shipboard Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
RS232 |
Rugged UPS FA00133 |
|
---|---|
Double Conversion, Online, Global Input, Extreme High Temperature UPS for Industrial Applications. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
115 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00135 |
|
---|---|
2500VA, 2000W, 115VAC 60Hz Input and 115VAC 60Hz Output, Double Conversion, Rugged, On-Line UPS with Power Factor Correction for Military Applications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
115 VAC |
Input Connector |
Terminal Block |
Output Connector |
Terminal Block |
Communication |
RS232 |
Rugged UPS FA00138 |
|
---|---|
3000VA, 3000W, 120/240VAC 50/60Hz Input and 120VAC 60Hz Output UPS. |
|
Power Rating |
2700-6000 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
Terminal Block |
Output Connector |
Terminal Block |
Communication |
None |
Rugged UPS FA00141 |
|
---|---|
5000VA, 4200W, 115/230VAC 50/60Hz Input and 230VAC 60Hz Output UPS. |
|
Power Rating |
2700-6000 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
230 VAC |
Input Connector |
Terminal Block |
Output Connector |
Terminal Block |
Communication |
None |
Rugged UPS FA00145 |
|
---|---|
Double Conversion, Online, UPS System for Ground Applications. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00146 |
|
---|---|
500 VA, 350 W, 120/240VAC, 50/60 Hz Input, and 120VAC 60Hz and 24VDC Output UPS. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00148 |
|
---|---|
Rugged, Double Conversion, High Temperature, Isolated 120VAC Input & 120VAC Output On Line UPS System with Power Factor Correction and Fixed Internal Battery for Industrial Applications. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00162 |
|
---|---|
AC Input UPS with internal batteries, extreme high temperature rugged rack mount double conversion on line UPS 72VDC in and 120VAC out at 60Hz with for Industrial Applications in a 2U enclosure. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
VDC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00171 |
|
---|---|
1500VA, 1050W, 115/230Vac 45-450Hz Global Isolated Input, 120Vac 60Hz Output, Freq Changer, 5BFB (9Ah), 3U20, Steel, IEC60320-C20, SNMP, Aux. Batt., 4 x NEMA |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 or 230 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00188 |
|
---|---|
Rugged, Double Conversion, High Temperature, Isolated 120VAC Input & 120VAC Output On Line UPS System with Power Factor Correction for Industrial Applications. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
Terminal Block |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00190 |
|
---|---|
2000 VA, 1800 Watts, 120 or 240 VAC, 50 or 60 Hz Input and 120 VAC, 60 Hz Output, Double Conversion, On-Line, Isolated, Rugged UPS with Power Factor Correction for Military Applications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00200 |
|
---|---|
5KVA, 4KW, Double Conversion, On Line, Isolated 115VAC, 60Hz 3-Phase Delta Input UPS with 120VAC, 60Hz Single Phase Output and Power Factor Correction for Shipboard Applications. |
|
Power Rating |
2700-6000 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
None |
Rugged UPS FA00203 |
|
---|---|
2,000 VA, 1800 Watts, Global Input Voltage, Output Voltage at 120VAC at 60Hz 1.5Hz UPS |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00207 |
|
---|---|
650VA, 450W, 120Vac 45/450Hz Non-Isolated Input, 120Vac 50/60 Hz Output, Freq Follower, 2BFB, 2U18.075, Steel, IEC-C14, Model F RS232, 4 x NEMA |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00213 |
|
---|---|
3000VA, 2400W, Isolated 208VAC Single Phase 60Hz Input and 120VAC, 60Hz Output, Double Conversion Input On-Line UPS and Power Conditioning System with Internal Batteries and Power Factor Correction. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
208 VAC |
Output Voltage |
120 VAC |
Input Connector |
Pigtail |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00236 |
|
---|---|
2000VA, 1400W Output, Double Conversion, Rugged, High Temperature, Global Wide Range, PFC Input, 85 to 265VAC Input, 50/60Hz Input, Online UPS Providing 120VAC, 50/60Hz Output with approximately 27-minute Battery Back Up, Power Factor Correction, Power Conversion and Power Conditioning in a 4U Aluminum Enclosure. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
4U - 6U Rackmount |
Input Voltage |
85 to 265 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
Circular Mil |
Communication |
RS232 |
Rugged UPS FA00242 |
|
---|---|
1500VA, 1050W High Temperature Double Conversion On-Line Global Input UPS with 120VAC, 60Hz Output and Power Factor Correction. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00243 |
|
---|---|
1500VA, 1200W High Temp, Double Conversion, On-Line Global Input UPS with 120VAC, 60Hz Output and Power Factor Correction. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
Circular Mil |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00244 |
|
---|---|
1100VA, 850W High Temperature, Double Conversion, Global Input UPS with 28VDC Output and Power Factor Correction. |
|
Power Rating |
150-999 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
VDC |
Input Connector |
Circular Mil |
Output Connector |
None |
Communication |
SNMP |
Rugged UPS FA00249 |
|
---|---|
2500VA, 2000W, Wide Range 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
85 to 265 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00252 |
|
---|---|
Global Input, 2KVA, 1.4kw, 120VAC, 60Hz Output UPS with 4 pure lead acid batteries. |
|
Power Rating |
1400-2099 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00269 |
|
---|---|
1150 VA, 1000 Watts, 120 or 240 VAC, 45 to 70 Hz Input and 120 VAC, 50 or 60 Hz Output, Double Conversion, On-Line, Isolated, Rugged UPS with Power Factor Correction. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
Briefcase |
Input Voltage |
120 or 240 VAC |
Output Voltage |
120 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00274 |
|
---|---|
1500VA, 1050W, 120VAC at 60Hz Input and 120VAC at 60Hz Output, Double Conversion, Rugged, High Temperature, Online UPS with Power Factor Correction for Industrial Applications. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
Vertical-Free Standing |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00281 |
|
---|---|
Rugged, Double Conversion, High Temperature, Isolated, Auto Select 120/240VAC Global Input & 240VAC Output Online UPS System with Power Factor Correction for Industrial Applications. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 or 240 VAC |
Output Voltage |
240 VAC |
Input Connector |
NEMA |
Output Connector |
IEC |
Communication |
RS232 |
Rugged UPS FA00287 |
|
---|---|
3kVA, 3kW High Temperature, Double Conversion, On-Line, Isolated, 230VAC, 50/60Hz Input UPS with 120VAC, 60Hz Output, Power Factor Correction and Extended Internal Batteries. |
|
Power Rating |
2700-6000 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
230 VAC |
Output Voltage |
230 VAC |
Input Connector |
IEC |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00294 |
|
---|---|
3000RM, 2100w, 120VAC Input, FC60, 120VAC Output, 7BFB, 3U20 UPS |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
RS232 |
Rugged UPS FA00297 |
|
---|---|
3000VA, 2100W, 230VAC, 50/60Hz Input and 230VAC 60Hz Output UPS. |
|
Power Rating |
2100-2699 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
230 VAC |
Output Voltage |
230 VAC |
Input Connector |
Pigtail |
Output Connector |
Pigtail |
Communication |
RS232 |
Rugged UPS FA00299 |
|
---|---|
1500VA, 1.25kw, Vertical, 120V, Isolated, 26CBHS, 52V, 3U22.2 UPS |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
Vertical-Free Standing |
Input Voltage |
120 VAC |
Output Voltage |
120 VAC |
Input Connector |
Terminal Block |
Output Connector |
Terminal Block |
Communication |
SNMP |
Rugged UPS FA00305 |
|
---|---|
1500VA, 1350W, 115VAC at 60Hz Input and 115VAC at 60Hz Output, Double Conversion, Rugged, High Temperature, Isolated Online UPS with Hot Swap Battery Drawer and Power Factor Correction for Navy Shipboard Applications. |
|
Power Rating |
1000-1399 Watts |
Chassis Configuration |
1U - 3U Rackmount |
Input Voltage |
115 VAC |
Output Voltage |
115 VAC |
Input Connector |
NEMA |
Output Connector |
NEMA |
Communication |
SNMP |
Rugged UPS FA00307 |
|
---|---|
6000 VA, 4500 W, 440 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS. Power factor correction for Navy shipboard applications. |
|
Power Rating |
2700-6000 Watts |
|