Meatest - M109R High Resistance Decade
Mechanic high resistance decade with RS232 remote control for voltages up to 5 kV. Internal battery for up to 3 hours of on site calibration.
- 12 GΩ and 5 kVdc limits
- Voltage limit indication
- Battery-powered
- Remote control via RS232 bus
M109R High Resistance Decade is designed for calibration of insulation meters and megaohmmeters and resistance ranges of safety testers, HIPOT testers or any other DC high resistance meter with test voltage up to 5 kV. Maximum voltage rating is indicated on front panel to ensure safety in operation. Internal rechargeable battery for up to 3 hours of grid-independent operation is standard part of delivery.
Connectivity
Even though the M109R looks mechanical, internal resistance standards are switched electronically by relays. This way we could fit it with RS232 remote control so it can be used in Caliber or any other automated calibration solution.
|
DC resistance |
1 MΩ - 12 GΩ, 5 kV max. ± 0.1% / year |
|---|
More Product Information
- The BL128 Series provides a compact linear backlight solution ideal for space-constrained line scan applications.
- Its ultra-thin profile (less than ½”) minimizes vertical footprint, and bezel-free design along the length allows for placement of its emitting window right up to adjacent surfaces.
- While optimized for line scan setups, the BL128’s versatility extends to general-purpose machine vision lighting as a non-directional, highly diffuse bar light illuminator when needed.
All-in-One BERT and Sampling Oscilloscope
- Customized built-in 4ch sampling oscilloscope and 4ch BERT
- Fast measurement and high performance shorten test times, improve yields, and cut capital infrastructure costs
- Sampling Oscilloscope
- Fast: 250 ksamples/s to measure 1 Msamples in about 5 s
- High Sensitivity: –15 dBm (typ., SMF)
- Wide bandwidth: 35 GHz (optical, SMF), 25 GHz (optical, MMF), 40 GHz (electrical)
- Low Jitter: 200 fs rms (typ.)
- Both NRZ and PAM4 signal analysis, Supports 53-Gbaud analysis with PAM4
- Built-in 26/53 Gbaud Clock Recovery Unit (CRU) for both NRZ and PAM4
- NRZ Jitter component analysis
- BERT
- Low-Jitter PPG: 600 fs rms (typ.)
- High-sensitivity ED: 25 mV (typ.)
- Sampling Oscilloscope
- Built-in PC for stable fast performance
- Ideal for multiport RF/Microwave and high-speed digital signal testing
- Mix DC and RF/Microwave signals on one probe
- Long lifetime – typically over one million (1,000,000) touchdowns
- Excellent performance in temperatures ranging from 10 K to 200°C
- Probe on any pad material with no damage
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.
- 20 ppm accuracy
- 13°C - 33°C reference temp. range
- 100 V @ 25 mA output capacity
Series of single resistance, capacitance and inductance decadic standards for calibration of ohm meters, LCR meters and multimeters.
- Traceable, accurate and stable
- Low time constant
- Low temperature coefficient
- Modular
- Control up to 95 assets
- Control multiple AC and DC power supplies and loads in one mainframe
- Create “virtual assets”
- Web browser control
- User configurable
- Highest Power Density
- Simple integration
- PFC
- Universal AC/DC input
- Up to 6kW in one mainframe
- 1kW DC modules
- PFC ≥0.95
- Reduced space and logistics hassles
- High power density
- Handles DC and AC power and load modules
- User configurable
- Universal AC/DC input
- Ease of integration
- Web browser control
- Trigger bus
- Configure modules to parallel or series operation “on the fly”
-
High SNR mode (up to 24 dB better signal-to-noise ratio)
-
Low-noise binning mode
-
Shading correction
-
Defect pixel correction
-
Area of interest (AOI), separate AOI for auto features
-
Binning
-
Sub-sampling
-
Auto gain (manual gain control: 0 to 24.4 dB)
-
Auto exposure (48 µs to 67 s)
-
Auto white balance
-
Look-up table (LUT)
-
Hue, saturation
-
Color correction
-
Local color anti-aliasing
-
Reverse X/Y
-
Deferred image transport
-
Trigger programmable, level, single, bulk, programmable delay
-
Sequence mode (changes the camera settings on the fly)
-
SIS (secure image signature, time stamp for trigger, frame count etc.)
-
Storable user sets
-
Camera and IEEE 1394b cable (other configurations on request)
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.
-
High SNR mode (up to 24 dB better signal-to-noise ratio)
-
Low-noise binning mode
-
Smear reduction
-
Shading correction
-
Defect pixel correction
-
Area of interest (AOI), separate AOI for auto features
-
Binning
-
Decimation
-
Auto gain (manual gain control: 0 to 24 dB)
-
Auto exposure (129 µs to 67 s)
-
Auto white balance
-
Look-up table (LUT)
-
Hue, saturation, color correction
-
Reverse X
-
Deferred image transport
-
Trigger programmable, level, single, bulk, programmable delay
-
Sequence mode (changes the camera settings on the fly)
-
SIS (secure image signature, time stamp for trigger, frame count)
-
Storable user sets
Meatest
We develop and manufacture electrical calibration instruments for calibration laboratories and testing facilities in electronics, engineering, utility, aeronautics and telecommunications sectors. Designed for automated calibrations our instruments bring effective solutions to customers like NPL, Samsung, Siemens and Volkswagen.
Contact Details
Meatest, spol. s r.o. Headquarters
Železná 509/3, Czech Republic - 619 00 BRNO
GPS: 49°10'13.93"N,16°36'53.2"E
Phone: 420-543-250-886
Fax: 420-543-250-890
Email: meatest@meatest.cz
Test & Measurement