Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.
Contact Details
Maury Microwave
2900 Inland Empire Blvd., Ontario California 91764, USA
Phone: 909-204-3306
Email: support@maurymw.com
Test & Measurement
Products
- Ultra-low distortion signal path
- Standard connectors SMA female
- 7” touch screen display
- Dimensions: 17.22 in. wide x 6.30 in. including feet, high x 19.5 in. deep
- Fold-down feet for bench top use
- Power 115 VAC, 60 Hz
- Operating Temperature: -10° to +65°C
- Differential inputs and outputs
- Multiple differential inputs and outputs
- 5” touch screen display
- Noise output through female N connector
- Ethernet connection for remote control
The NGX1000 programmable noise generator is a high performance, broadband additive white gaussian noise (AWGN) generator in an easy-to-use compact form factor. The streamlined user interface and flat menu structure provides a fast, simple way to add RF noise in a communications system to test reliability, robustness and performance.
All functionality of the generator is accessible through the 5” touch screen or via remote control through an ethernet connection delivering flexible, programmable noise generation for broad use in semiconductor, military, aerospace, satellite, medical and communications applications.
- Output White Gaussian noise
- 127 dB of attenuation; 0.1 dB step size
- Units > 2 GHz have total attenuation of 79.9 dB
- Low distortion signal path
- Noise attenuator accuracy:
- ±0.2 dB or 0.5% at 1 – 500 MHz
- ±0.2 dB or 1% at 0.5 – 1.0 GHz
- ±0.3 dB or 2% at 1 – 2 GHz
- Standard connectors SMA female
- Power 115 VAC, 60 Hz; 110 VAC, 220 VAC
- Operating Temperature: -10° to +65°C
- Output White Gaussian noise
- Output power up to +30 dBm
- 127 dB of attenuation; 0.1 dB step size
- Units > 2 GHz have total attenuation of 79.9 dB
- Low distortion signal path
- Power 115 VAC, 60 Hz
- Noise attenuator accuracy: ±0.2 dB or 0.5% at 1 – 500 MHz ±0.2 dB or 1% at 0.5 – 1.0 GHz ±0.3 dB or 2% at 1 – 2 GHz
- Standard connectors SMA female
- 7” touch screen display
- Dimensions: 17.25 in. wide x 6.50 in. including feet, high x 19.50 in. deep
- Removable hard drive for added security
- Operating Temperature: -10° to +65°C
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
- Dual-channel and differential voltage measurements
- 1% accuracy at full scale
- True RMS response below 30 mV
- Optional low-frequency probe for measurements from 10 Hz to 100 MHz
- DC recorder output
- IEEE-488 interface standard, RS-232
The 9240 series is the latest addition to the popular 9200 series of RF voltmeters. It combines accuracy, smart probes, and operator features that have never before been available in its price range. It is simple to use on the bench, and comprehensive enough to integrate into an ATE system. Boonton’s proven voltage probes directly measure from 200 μV to 10 V with usable indication as low as 50 μV and have true RMS response below 30 mV.
- Capture/display/analyze peak and average power
- Frequency range from 4 kHz to 40 GHz
- Industry-leading video bandwidth (195 MHz) and rise time (3 ns)
- Industry-leading 100,000 measurements per second
- Industry-leading 100 ps time resolution
- Synchronous multi-channel measurements (up to 4 channels)
- Sensors can be used as standalone instruments
- 4 kHz to 6 GHz and 10 MHz to 6, 18, and 40 GHz power sensors
- -60 dBm to +20 dBm dynamic range
- Pulse, Average, CW and Modulation modes
- True average measurements with essentially no modulation bandwidth limitations
- Real-Time Power Processing™ technology for virtually no gaps in signal acquisition and zero measurement latency
- 100,000 measurements per second
- Synchronized multi-channel measurements
- Suite of advanced measurement and analysis software
- 6 GHz, 8 GHz, 18 GHz and 40 GHz RF Power Sensors
- Up to 195 MHz video bandwidth with 3 ns rise time
- Real-Time Power ProcessingTM technology with zero measurement dead time
- 100,000 measurements per second
- Power Analyzer Suite advanced measurement and analysis software
- Crest factor, CCDF and statistical measurements
- 10 GS/s effective sample rate
- 100 MS/s continuous sample rate
- Synchronized multi-channel measurements
- Directly compatible with most commercial VNA’s
- Available as polynomial and characterized device kits
- Measure S-Parameters with uncertainty when used in conjunction with Maury’s Insight software platform
Maury offers coaxial and waveguide VNA calibration kits.
Coaxial calibration kits are offered in Polynomial SOLT, Characterized Device (CD) SOLT, and TRL, depending on the connector series. Where available, CD kits improve calibration accuracy when compared to SOLT kits based on polynomial definitions as each calibration kit is provided with individually characterized short, open and fixed load standards, whose S-parameters can be loaded into commercial VNAs directly or when used with Maury’s Insight™ software platform. When combined with Insight™, users will be able to quantify the uncertainty contribution of their calibration kit to their overall measurements. CD cal kits result in TRL-like accuracy with fixed-load SOLT ease-of-use.
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Coaxial air lines are air-dielectric transmission lines with highly accurate dimensions that can be used as fundamental impedance standards in measurement and calibration applications, and may also be used to establish reference positions for measurements.
Bead supported air lines offer greater convenience and easier connections (the center conductor is automatically aligned by the dielectric bead for easy connection); beadless air lines offer better impedance and electrical length accuracies, as well as lower VSWR (the center conductor floats free in the air line body, and the male connector nut is retractable to facilitate insertion of the center conductor contact before the thread- on connection tightened.