20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.  20 ppm accuracy  13°C - 33°C reference temp. range  100 V @ 25 mA output capacity
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions.  20 ppm accuracy 13°C - 33°C reference temp. range 100 V @ 25 mA output capacity
3000W power load based on set of 64 fixed, high-power resistors. Maximum load 3 kW and 250 Vrms Real resistance function Temperature coefficient < 10 ppm/°C
3000W power load based on Real-Resistance decade design with built-in multimeter for simulation of constant power and constant current functions.  Maximum load 3 kW and 250 Vrms Real resistance function Temperature coefficient < 10 ppm/°C
High resistance decade with built-in test signal meter for calibration of high resistance meters up to 6 kV. Based on M6xx Real-Resistance decade series with short function for short current testing. 10 kΩ - 100.0 GΩ, short function Hot-switching up to 6 kVdc limit Test voltage and current indication
Programmable capacitance decade with continuous range from 100 pF to 100 uF. Based on M6xx Real-Resistance decade series for great user comfort.  0.25% accuracy, maximum voltage 50 V Grounded / floating operation User defined conversion tables
Bank of fixed resistance, capacitance and inductance standards with defined frequency characteristic up to 1 MHz for automated calibration of LCR meters. Automated RCL calibration Calibration data from 20 Hz to 1 MHz No need for pen and paper method
Resistance decade box designed for RTD and other resistance-based sensors' simulation. 0.01°C accuracy and 0.001°C resolution.  Real resistors switched by relays Custom temperature scales No residual resistance 0.01°C accuracy Six different languages
Resistance decade box with 1 Ω - 1.2 MΩ range, high accuracy and temperature stability. Best resolution 10 μΩ, RTD temperature sensor simulation feature. Real resistors switched by relays Custom units and time sequences No residual resistance 20 ppm accuracy Six different languages
Resistance decade box designed for RTD and other resistance-based sensors' simulation. 0.1°C accuracy and 5W load capacity. Real resistors switched by relays Custom temperature scales No residual resistance 5 W load capacity Six different languages
Resistance decade box with 100 mΩ - 22 MΩ range and 5W load capacity. Best resolution 1 μΩ, RTD temperature sensor simulation feature. Real resistors switched by relays 14 decade range, resolution from 1 μΩ Custom units and time sequences No residual resistance 5 W load capacity Six different languages
Series of single resistance, capacitance and inductance decadic standards for calibration of ohm meters, LCR meters and multimeters.  Traceable, accurate and stable Low time constant Low temperature coefficient